Effect of soil type and grade of concrete on amount of steel for reinforced concrete hospital building with seismic design

Current practice in Malaysia nowadays is not consider the seismic precaution since Malaysia is not located in active seismic fault zone. Most building in Malaysia had been designed based on BS8110. Engineers considered Malaysia is safe from earthquake until in June 2015, Malaysia was surprised by an...

Full description

Saved in:
Bibliographic Details
Main Author: Syaqierah Tang, Saka
Format: Undergraduates Project Papers
Language:English
Published: 2018
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/26214/1/Effect%20of%20soil%20type%20and%20grade%20of%20concrete%20on%20amount%20of%20steel%20for%20reinforced%20concrete%20hospital%20building.pdf
http://umpir.ump.edu.my/id/eprint/26214/
https://efind.ump.edu.my/cgi-bin/koha/opac-detail.pl?biblionumber=7839
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaysia Pahang
Language: English
id my.ump.umpir.26214
record_format eprints
spelling my.ump.umpir.262142019-10-25T02:35:39Z http://umpir.ump.edu.my/id/eprint/26214/ Effect of soil type and grade of concrete on amount of steel for reinforced concrete hospital building with seismic design Syaqierah Tang, Saka TA Engineering (General). Civil engineering (General) Current practice in Malaysia nowadays is not consider the seismic precaution since Malaysia is not located in active seismic fault zone. Most building in Malaysia had been designed based on BS8110. Engineers considered Malaysia is safe from earthquake until in June 2015, Malaysia was surprised by an unexpected tremor with magnitude Mw 6.0 on 7.15 am in the morning in Ranau, Sabah. The tremors was felt in Kundasang, Tambunan, Pedalaman, Tuaran, Kota Kinabalu, and Kota Belud. This incident open people’s eyes and minds about the risk of earthquake. Since hospital building is one of significant structure for public necessity as an medical institution and need to accommodate lot of people, it must be able to resist seismic load whenever earthquake happen and it is strongly related with the strength of the structure. Hence, this research investigated the amount of steel reinforcement for reinforced concrete hospital building with seismic design. The analysis conducted by using four types of soil and two grades of concrete. There are nine models used for the analysis designed based on Eurocode 8 and conducted by using Tekla Structural Design software. Based on the result, it can be concluded that Soil Type D required steel reinforcement 110% higher when compared to non seismic design when used concrete grade G30. While for the effect of grade of concrete, grade of concrete G30 required more amount of steel reinforcement than grade of concrete G40 around 41.8% when the structure built on Soil Type D. Therefore, type of soil and grade of concrete should be taken into consideration for seismic building design. 2018-06 Undergraduates Project Papers NonPeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/26214/1/Effect%20of%20soil%20type%20and%20grade%20of%20concrete%20on%20amount%20of%20steel%20for%20reinforced%20concrete%20hospital%20building.pdf Syaqierah Tang, Saka (2018) Effect of soil type and grade of concrete on amount of steel for reinforced concrete hospital building with seismic design. Faculty of Civil Engineering and Earth Resources, Universiti Malaysia Pahang. https://efind.ump.edu.my/cgi-bin/koha/opac-detail.pl?biblionumber=7839
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Syaqierah Tang, Saka
Effect of soil type and grade of concrete on amount of steel for reinforced concrete hospital building with seismic design
description Current practice in Malaysia nowadays is not consider the seismic precaution since Malaysia is not located in active seismic fault zone. Most building in Malaysia had been designed based on BS8110. Engineers considered Malaysia is safe from earthquake until in June 2015, Malaysia was surprised by an unexpected tremor with magnitude Mw 6.0 on 7.15 am in the morning in Ranau, Sabah. The tremors was felt in Kundasang, Tambunan, Pedalaman, Tuaran, Kota Kinabalu, and Kota Belud. This incident open people’s eyes and minds about the risk of earthquake. Since hospital building is one of significant structure for public necessity as an medical institution and need to accommodate lot of people, it must be able to resist seismic load whenever earthquake happen and it is strongly related with the strength of the structure. Hence, this research investigated the amount of steel reinforcement for reinforced concrete hospital building with seismic design. The analysis conducted by using four types of soil and two grades of concrete. There are nine models used for the analysis designed based on Eurocode 8 and conducted by using Tekla Structural Design software. Based on the result, it can be concluded that Soil Type D required steel reinforcement 110% higher when compared to non seismic design when used concrete grade G30. While for the effect of grade of concrete, grade of concrete G30 required more amount of steel reinforcement than grade of concrete G40 around 41.8% when the structure built on Soil Type D. Therefore, type of soil and grade of concrete should be taken into consideration for seismic building design.
format Undergraduates Project Papers
author Syaqierah Tang, Saka
author_facet Syaqierah Tang, Saka
author_sort Syaqierah Tang, Saka
title Effect of soil type and grade of concrete on amount of steel for reinforced concrete hospital building with seismic design
title_short Effect of soil type and grade of concrete on amount of steel for reinforced concrete hospital building with seismic design
title_full Effect of soil type and grade of concrete on amount of steel for reinforced concrete hospital building with seismic design
title_fullStr Effect of soil type and grade of concrete on amount of steel for reinforced concrete hospital building with seismic design
title_full_unstemmed Effect of soil type and grade of concrete on amount of steel for reinforced concrete hospital building with seismic design
title_sort effect of soil type and grade of concrete on amount of steel for reinforced concrete hospital building with seismic design
publishDate 2018
url http://umpir.ump.edu.my/id/eprint/26214/1/Effect%20of%20soil%20type%20and%20grade%20of%20concrete%20on%20amount%20of%20steel%20for%20reinforced%20concrete%20hospital%20building.pdf
http://umpir.ump.edu.my/id/eprint/26214/
https://efind.ump.edu.my/cgi-bin/koha/opac-detail.pl?biblionumber=7839
_version_ 1648741271083155456