Experimental study on the performance of vortex tube cooling device on a cooling jacket
A vortex tube is an intriguing simple device which is capable of generating cold and hot streams from a single compressed fluid supply at room temperature. The vortex tube does not require any refrigerants or chemicals to operate which makes it an environmentally friendly device. Still, as a well co...
Saved in:
Main Authors: | , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
IOP Publishing
2020
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/28478/13/Experimental%20study%20on%20the%20performance.pdf http://umpir.ump.edu.my/id/eprint/28478/ https://doi.org/10.1088/1755-1315/581/1/012018 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaysia Pahang |
Language: | English |
id |
my.ump.umpir.28478 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.284782021-02-03T01:10:04Z http://umpir.ump.edu.my/id/eprint/28478/ Experimental study on the performance of vortex tube cooling device on a cooling jacket Lim, Sheh Hong Muhammad Fadhli, Suhaimi Mohd Hazwan, Yusof TJ Mechanical engineering and machinery A vortex tube is an intriguing simple device which is capable of generating cold and hot streams from a single compressed fluid supply at room temperature. The vortex tube does not require any refrigerants or chemicals to operate which makes it an environmentally friendly device. Still, as a well cooling device, there are fewer or no research works that were conducted on the application of vortex tube. So, the application of vortex tube as a cooling device on a cooling jacket is less explored. Hence, the performance of this application on experimental research is unclear. Therefore, the objectives for this research are to determine the performance of vortex tube as a cooling device on a cooling jacket at different cold mass flow rate and also to determine the performance of vortex tube as a cooling device on a cooling jacket at different inlet pressure. The performance of vortex tube on the cooling jacket is experimented with different cold mass flow rate ranging from 30L/min to 90L/min and different inlet pressure ranging from 200kPa to 500kPa. Both parameters were with several condition, which are conducted at indoor condition, inside an air-ventilated room and outdoor condition, under the sunlight. At the end of the experiment, 90L/min and 500kPa were the optimum value for the performance of vortex tube. It can be concluded that the higher the inlet pressure supplied to the vortex tube, the lower the air temperature produced, and the higher the cold mass flow rate, enables lower cold air generated to the cooling jacket. IOP Publishing 2020 Conference or Workshop Item PeerReviewed pdf en cc_by http://umpir.ump.edu.my/id/eprint/28478/13/Experimental%20study%20on%20the%20performance.pdf Lim, Sheh Hong and Muhammad Fadhli, Suhaimi and Mohd Hazwan, Yusof (2020) Experimental study on the performance of vortex tube cooling device on a cooling jacket. In: IOP Conference Series: Earth and Environmental Science, 10th International Conference on Future Environment and Energy, 7-9 January 2020 , Kyoto, Japan. pp. 1-8., 581 (012018). ISSN 1755-1315 https://doi.org/10.1088/1755-1315/581/1/012018 |
institution |
Universiti Malaysia Pahang |
building |
UMP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang |
content_source |
UMP Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English |
topic |
TJ Mechanical engineering and machinery |
spellingShingle |
TJ Mechanical engineering and machinery Lim, Sheh Hong Muhammad Fadhli, Suhaimi Mohd Hazwan, Yusof Experimental study on the performance of vortex tube cooling device on a cooling jacket |
description |
A vortex tube is an intriguing simple device which is capable of generating cold and hot streams from a single compressed fluid supply at room temperature. The vortex tube does not require any refrigerants or chemicals to operate which makes it an environmentally friendly device. Still, as a well cooling device, there are fewer or no research works that were conducted on the application of vortex tube. So, the application of vortex tube as a cooling device on a cooling jacket is less explored. Hence, the performance of this application on experimental research is unclear. Therefore, the objectives for this research are to determine the performance of vortex tube as a cooling device on a cooling jacket at different cold mass flow rate and also to determine the performance of vortex tube as a cooling device on a cooling jacket at different inlet pressure. The performance of vortex tube on the cooling jacket is experimented with different cold mass flow rate ranging from 30L/min to 90L/min and different inlet pressure ranging from 200kPa to 500kPa. Both parameters were with several condition, which are conducted at indoor condition, inside an air-ventilated room and outdoor condition, under the sunlight. At the end of the experiment, 90L/min and 500kPa were the optimum value for the performance of vortex tube. It can be concluded that the higher the inlet pressure supplied to the vortex tube, the lower the air temperature produced, and the higher the cold mass flow rate, enables lower cold air generated to the cooling jacket. |
format |
Conference or Workshop Item |
author |
Lim, Sheh Hong Muhammad Fadhli, Suhaimi Mohd Hazwan, Yusof |
author_facet |
Lim, Sheh Hong Muhammad Fadhli, Suhaimi Mohd Hazwan, Yusof |
author_sort |
Lim, Sheh Hong |
title |
Experimental study on the performance of vortex tube cooling device on a cooling jacket |
title_short |
Experimental study on the performance of vortex tube cooling device on a cooling jacket |
title_full |
Experimental study on the performance of vortex tube cooling device on a cooling jacket |
title_fullStr |
Experimental study on the performance of vortex tube cooling device on a cooling jacket |
title_full_unstemmed |
Experimental study on the performance of vortex tube cooling device on a cooling jacket |
title_sort |
experimental study on the performance of vortex tube cooling device on a cooling jacket |
publisher |
IOP Publishing |
publishDate |
2020 |
url |
http://umpir.ump.edu.my/id/eprint/28478/13/Experimental%20study%20on%20the%20performance.pdf http://umpir.ump.edu.my/id/eprint/28478/ https://doi.org/10.1088/1755-1315/581/1/012018 |
_version_ |
1691733253350752256 |