Compression test of built-up sigma section cold-formed steel column with holes
An experimental investigation was conducted to study the Compression test of built-up sigma section cold-formed steel Column holes and to determine the maximum compression load of sigma section Cold-Formed steel column. A total 8 specimen of steel column with holes and without holes and also thickne...
Saved in:
Main Author: | |
---|---|
Format: | Undergraduates Project Papers |
Language: | English |
Published: |
2019
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/29546/1/16.Compression%20test%20of%20built-up%20sigma%20section%20cold-formed%20steel%20column%20with%20holes.pdf http://umpir.ump.edu.my/id/eprint/29546/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaysia Pahang |
Language: | English |
id |
my.ump.umpir.29546 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.295462023-08-15T00:32:31Z http://umpir.ump.edu.my/id/eprint/29546/ Compression test of built-up sigma section cold-formed steel column with holes Nurul Faizah, Muhammad Rusli TA Engineering (General). Civil engineering (General) An experimental investigation was conducted to study the Compression test of built-up sigma section cold-formed steel Column holes and to determine the maximum compression load of sigma section Cold-Formed steel column. A total 8 specimen of steel column with holes and without holes and also thickness 1.2 and 2.0 mm were tested using universal testing machine (UTM). Typical applications include framing for windows, doorways, shear walls, and multi-story cold-formed steel framed buildings in which the lower floor utilizes built-up studs to carry the load. The built-up studs in this study consisted of eight Sigma sections oriented back-to-back forming an I-shaped crosssection. For each specimen, the studs were connected to each other with two self-drilling screws spaced at a set interval. A cold-formed steel track section was connected running perpendicular to each end of the built-up stud with a single self-drilling screw through each of the sigma sections. The purpose of the column section was to keep the ends of the studs together and represents a common end attachment. As a result of the investigation, the maximum compression load was shown and the mode of failure of coldformed steel column with the various position of holes. 2019-05 Undergraduates Project Papers NonPeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/29546/1/16.Compression%20test%20of%20built-up%20sigma%20section%20cold-formed%20steel%20column%20with%20holes.pdf Nurul Faizah, Muhammad Rusli (2019) Compression test of built-up sigma section cold-formed steel column with holes. Faculty of Civil Engineering and Earth Resources, Universiti Malaysia Pahang. |
institution |
Universiti Malaysia Pahang |
building |
UMP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang |
content_source |
UMP Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English |
topic |
TA Engineering (General). Civil engineering (General) |
spellingShingle |
TA Engineering (General). Civil engineering (General) Nurul Faizah, Muhammad Rusli Compression test of built-up sigma section cold-formed steel column with holes |
description |
An experimental investigation was conducted to study the Compression test of built-up sigma section cold-formed steel Column holes and to determine the maximum compression load of sigma section Cold-Formed steel column. A total 8 specimen of steel column with holes and without holes and also thickness 1.2 and 2.0 mm were tested using universal testing machine (UTM). Typical applications include framing for windows, doorways, shear walls, and multi-story cold-formed steel framed buildings in which the lower floor utilizes built-up studs to carry the load. The built-up studs in this study consisted of eight Sigma sections oriented back-to-back forming an I-shaped crosssection. For each specimen, the studs were connected to each other with two self-drilling screws spaced at a set interval. A cold-formed steel track section was connected running perpendicular to each end of the built-up stud with a single self-drilling screw through each of the sigma sections. The purpose of the column section was to keep the ends of the studs together and represents a common end attachment. As a result of the investigation, the maximum compression load was shown and the mode of failure of coldformed steel column with the various position of holes. |
format |
Undergraduates Project Papers |
author |
Nurul Faizah, Muhammad Rusli |
author_facet |
Nurul Faizah, Muhammad Rusli |
author_sort |
Nurul Faizah, Muhammad Rusli |
title |
Compression test of built-up sigma section cold-formed steel column with holes |
title_short |
Compression test of built-up sigma section cold-formed steel column with holes |
title_full |
Compression test of built-up sigma section cold-formed steel column with holes |
title_fullStr |
Compression test of built-up sigma section cold-formed steel column with holes |
title_full_unstemmed |
Compression test of built-up sigma section cold-formed steel column with holes |
title_sort |
compression test of built-up sigma section cold-formed steel column with holes |
publishDate |
2019 |
url |
http://umpir.ump.edu.my/id/eprint/29546/1/16.Compression%20test%20of%20built-up%20sigma%20section%20cold-formed%20steel%20column%20with%20holes.pdf http://umpir.ump.edu.my/id/eprint/29546/ |
_version_ |
1775622226909855744 |