Compression test of built-up sigma section cold-formed steel column with holes

An experimental investigation was conducted to study the Compression test of built-up sigma section cold-formed steel Column holes and to determine the maximum compression load of sigma section Cold-Formed steel column. A total 8 specimen of steel column with holes and without holes and also thickne...

Full description

Saved in:
Bibliographic Details
Main Author: Nurul Faizah, Muhammad Rusli
Format: Undergraduates Project Papers
Language:English
Published: 2019
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/29546/1/16.Compression%20test%20of%20built-up%20sigma%20section%20cold-formed%20steel%20column%20with%20holes.pdf
http://umpir.ump.edu.my/id/eprint/29546/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaysia Pahang
Language: English
id my.ump.umpir.29546
record_format eprints
spelling my.ump.umpir.295462023-08-15T00:32:31Z http://umpir.ump.edu.my/id/eprint/29546/ Compression test of built-up sigma section cold-formed steel column with holes Nurul Faizah, Muhammad Rusli TA Engineering (General). Civil engineering (General) An experimental investigation was conducted to study the Compression test of built-up sigma section cold-formed steel Column holes and to determine the maximum compression load of sigma section Cold-Formed steel column. A total 8 specimen of steel column with holes and without holes and also thickness 1.2 and 2.0 mm were tested using universal testing machine (UTM). Typical applications include framing for windows, doorways, shear walls, and multi-story cold-formed steel framed buildings in which the lower floor utilizes built-up studs to carry the load. The built-up studs in this study consisted of eight Sigma sections oriented back-to-back forming an I-shaped crosssection. For each specimen, the studs were connected to each other with two self-drilling screws spaced at a set interval. A cold-formed steel track section was connected running perpendicular to each end of the built-up stud with a single self-drilling screw through each of the sigma sections. The purpose of the column section was to keep the ends of the studs together and represents a common end attachment. As a result of the investigation, the maximum compression load was shown and the mode of failure of coldformed steel column with the various position of holes. 2019-05 Undergraduates Project Papers NonPeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/29546/1/16.Compression%20test%20of%20built-up%20sigma%20section%20cold-formed%20steel%20column%20with%20holes.pdf Nurul Faizah, Muhammad Rusli (2019) Compression test of built-up sigma section cold-formed steel column with holes. Faculty of Civil Engineering and Earth Resources, Universiti Malaysia Pahang.
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Nurul Faizah, Muhammad Rusli
Compression test of built-up sigma section cold-formed steel column with holes
description An experimental investigation was conducted to study the Compression test of built-up sigma section cold-formed steel Column holes and to determine the maximum compression load of sigma section Cold-Formed steel column. A total 8 specimen of steel column with holes and without holes and also thickness 1.2 and 2.0 mm were tested using universal testing machine (UTM). Typical applications include framing for windows, doorways, shear walls, and multi-story cold-formed steel framed buildings in which the lower floor utilizes built-up studs to carry the load. The built-up studs in this study consisted of eight Sigma sections oriented back-to-back forming an I-shaped crosssection. For each specimen, the studs were connected to each other with two self-drilling screws spaced at a set interval. A cold-formed steel track section was connected running perpendicular to each end of the built-up stud with a single self-drilling screw through each of the sigma sections. The purpose of the column section was to keep the ends of the studs together and represents a common end attachment. As a result of the investigation, the maximum compression load was shown and the mode of failure of coldformed steel column with the various position of holes.
format Undergraduates Project Papers
author Nurul Faizah, Muhammad Rusli
author_facet Nurul Faizah, Muhammad Rusli
author_sort Nurul Faizah, Muhammad Rusli
title Compression test of built-up sigma section cold-formed steel column with holes
title_short Compression test of built-up sigma section cold-formed steel column with holes
title_full Compression test of built-up sigma section cold-formed steel column with holes
title_fullStr Compression test of built-up sigma section cold-formed steel column with holes
title_full_unstemmed Compression test of built-up sigma section cold-formed steel column with holes
title_sort compression test of built-up sigma section cold-formed steel column with holes
publishDate 2019
url http://umpir.ump.edu.my/id/eprint/29546/1/16.Compression%20test%20of%20built-up%20sigma%20section%20cold-formed%20steel%20column%20with%20holes.pdf
http://umpir.ump.edu.my/id/eprint/29546/
_version_ 1775622226909855744