Thermal hydraulic performance for hybrid composition ratio of TiO2–SiO2 nanofluids in a tube with wire coil inserts

Hybrid nanofluids flows with wire coils are proven to be beneficial in improving the performance of heat transfer. The thermal-hydraulic performance with different hybrid composition ratio for two or more suspended nanoparticles in the hybrid nanofluids with wire coils is unknown. Therefore, the res...

Full description

Saved in:
Bibliographic Details
Main Authors: W. H., Azmi, K., Abdul Hamid, A. I., Ramadhan, A. I. M., Shaiful
Format: Article
Language:English
Published: Elsevier 2021
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/31413/1/Thermal%20hydraulic%20performance%20for%20hybrid%20composition%20ratio%20of%20TiO2.pdf
http://umpir.ump.edu.my/id/eprint/31413/
https://doi.org/10.1016/j.csite.2021.100899
https://doi.org/10.1016/j.csite.2021.100899
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaysia Pahang
Language: English
id my.ump.umpir.31413
record_format eprints
spelling my.ump.umpir.314132021-07-01T08:59:26Z http://umpir.ump.edu.my/id/eprint/31413/ Thermal hydraulic performance for hybrid composition ratio of TiO2–SiO2 nanofluids in a tube with wire coil inserts W. H., Azmi K., Abdul Hamid A. I., Ramadhan A. I. M., Shaiful TJ Mechanical engineering and machinery Hybrid nanofluids flows with wire coils are proven to be beneficial in improving the performance of heat transfer. The thermal-hydraulic performance with different hybrid composition ratio for two or more suspended nanoparticles in the hybrid nanofluids with wire coils is unknown. Therefore, the research work was carried out to evaluate the effect of hybrid composition ratio on the overall system performance for flow with wire coils. The TiO2–SiO2 nanofluids was prepared at constant 1.0% of volume concentration and hybrid composition ratio, R of TiO2 to SiO2 nanoparticles at variation of 0.2, 0.4, 0.5, 0.6, and 0.8. The wire coils were studied for various pitch ratio up to 4.17. The TiO2–SiO2 nanofluids heat transfer was improved up to 211.75% for flow with wire coils. The best thermal performance factor (TPF) was exceeded 1.72 and performed with R = 0.2 composition ratio and pitch ratio of 0.83. The present TPF for hybrid nanofluids is higher than TPF for existing single nanofluids hence confirmed the applicability of TiO2–SiO2 nanofluids at R = 0.2 composition ratio flow with wire coils. Elsevier 2021-06 Article PeerReviewed pdf en cc_by_4 http://umpir.ump.edu.my/id/eprint/31413/1/Thermal%20hydraulic%20performance%20for%20hybrid%20composition%20ratio%20of%20TiO2.pdf W. H., Azmi and K., Abdul Hamid and A. I., Ramadhan and A. I. M., Shaiful (2021) Thermal hydraulic performance for hybrid composition ratio of TiO2–SiO2 nanofluids in a tube with wire coil inserts. Case Studies in Thermal Engineering, 25 (100899). pp. 1-14. ISSN 2214-157X https://doi.org/10.1016/j.csite.2021.100899 https://doi.org/10.1016/j.csite.2021.100899
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
W. H., Azmi
K., Abdul Hamid
A. I., Ramadhan
A. I. M., Shaiful
Thermal hydraulic performance for hybrid composition ratio of TiO2–SiO2 nanofluids in a tube with wire coil inserts
description Hybrid nanofluids flows with wire coils are proven to be beneficial in improving the performance of heat transfer. The thermal-hydraulic performance with different hybrid composition ratio for two or more suspended nanoparticles in the hybrid nanofluids with wire coils is unknown. Therefore, the research work was carried out to evaluate the effect of hybrid composition ratio on the overall system performance for flow with wire coils. The TiO2–SiO2 nanofluids was prepared at constant 1.0% of volume concentration and hybrid composition ratio, R of TiO2 to SiO2 nanoparticles at variation of 0.2, 0.4, 0.5, 0.6, and 0.8. The wire coils were studied for various pitch ratio up to 4.17. The TiO2–SiO2 nanofluids heat transfer was improved up to 211.75% for flow with wire coils. The best thermal performance factor (TPF) was exceeded 1.72 and performed with R = 0.2 composition ratio and pitch ratio of 0.83. The present TPF for hybrid nanofluids is higher than TPF for existing single nanofluids hence confirmed the applicability of TiO2–SiO2 nanofluids at R = 0.2 composition ratio flow with wire coils.
format Article
author W. H., Azmi
K., Abdul Hamid
A. I., Ramadhan
A. I. M., Shaiful
author_facet W. H., Azmi
K., Abdul Hamid
A. I., Ramadhan
A. I. M., Shaiful
author_sort W. H., Azmi
title Thermal hydraulic performance for hybrid composition ratio of TiO2–SiO2 nanofluids in a tube with wire coil inserts
title_short Thermal hydraulic performance for hybrid composition ratio of TiO2–SiO2 nanofluids in a tube with wire coil inserts
title_full Thermal hydraulic performance for hybrid composition ratio of TiO2–SiO2 nanofluids in a tube with wire coil inserts
title_fullStr Thermal hydraulic performance for hybrid composition ratio of TiO2–SiO2 nanofluids in a tube with wire coil inserts
title_full_unstemmed Thermal hydraulic performance for hybrid composition ratio of TiO2–SiO2 nanofluids in a tube with wire coil inserts
title_sort thermal hydraulic performance for hybrid composition ratio of tio2–sio2 nanofluids in a tube with wire coil inserts
publisher Elsevier
publishDate 2021
url http://umpir.ump.edu.my/id/eprint/31413/1/Thermal%20hydraulic%20performance%20for%20hybrid%20composition%20ratio%20of%20TiO2.pdf
http://umpir.ump.edu.my/id/eprint/31413/
https://doi.org/10.1016/j.csite.2021.100899
https://doi.org/10.1016/j.csite.2021.100899
_version_ 1705057024090308608