Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application

This work aims to study the effect of mechanical treatment technique on titanium coated with PVD for the enhancement of corrosion resistance for the biomedical implant. First, substrates were coated with TiN via PVD then applied the mechanical treatment through ultrasonic vibration. Results show tha...

Full description

Saved in:
Bibliographic Details
Main Authors: A., Shah, Siti Nurul Fasehah, Ismail, Mas Ayu, Hassan, R., Daud, Che Ghani, Che Kob
Format: Conference or Workshop Item
Language:English
Published: IOP Publishing 2021
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/32008/1/Improvement%20of%20corrosion%20resistance%20of%20tin%20coated%20on%20titanium.pdf
http://umpir.ump.edu.my/id/eprint/32008/
https://doi.org/10.1088/1742-6596/1823/1/012111
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaysia Pahang
Language: English
id my.ump.umpir.32008
record_format eprints
spelling my.ump.umpir.320082022-02-11T08:15:52Z http://umpir.ump.edu.my/id/eprint/32008/ Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application A., Shah Siti Nurul Fasehah, Ismail Mas Ayu, Hassan R., Daud Che Ghani, Che Kob T Technology (General) TJ Mechanical engineering and machinery TS Manufactures This work aims to study the effect of mechanical treatment technique on titanium coated with PVD for the enhancement of corrosion resistance for the biomedical implant. First, substrates were coated with TiN via PVD then applied the mechanical treatment through ultrasonic vibration. Results show that all coated samples treated with ultrasonic vibration improve the surface of the coated sample and produce a compact coating as compared with a substrate coated without mechanical treatment. The corrosion test evaluated by Potentiodynamic polarization and Electrochemical Impedance Spectroscopy indicated that all coated samples treated with mechanical treatment showed high corrosion resistance as compared with the untreated sample. It can be concluded that mechanical treatment which is a simple technic can be used as an alternative to improve the corrosion resistance thus reduce the implant and manufacturing cost for biomedical applications. IOP Publishing 2021-03-31 Conference or Workshop Item PeerReviewed pdf en cc_by http://umpir.ump.edu.my/id/eprint/32008/1/Improvement%20of%20corrosion%20resistance%20of%20tin%20coated%20on%20titanium.pdf A., Shah and Siti Nurul Fasehah, Ismail and Mas Ayu, Hassan and R., Daud and Che Ghani, Che Kob (2021) Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application. In: Journal of Physics: Conference Series; 2nd UPY International Conference on Applied Science and Education, UPINCASE 2020, 3 - 4 November 2020 , Yogyakarta, Virtual. pp. 1-10., 1823 (1). ISSN 1742-6588 (print); 1742-6596 (online) https://doi.org/10.1088/1742-6596/1823/1/012111
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic T Technology (General)
TJ Mechanical engineering and machinery
TS Manufactures
spellingShingle T Technology (General)
TJ Mechanical engineering and machinery
TS Manufactures
A., Shah
Siti Nurul Fasehah, Ismail
Mas Ayu, Hassan
R., Daud
Che Ghani, Che Kob
Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application
description This work aims to study the effect of mechanical treatment technique on titanium coated with PVD for the enhancement of corrosion resistance for the biomedical implant. First, substrates were coated with TiN via PVD then applied the mechanical treatment through ultrasonic vibration. Results show that all coated samples treated with ultrasonic vibration improve the surface of the coated sample and produce a compact coating as compared with a substrate coated without mechanical treatment. The corrosion test evaluated by Potentiodynamic polarization and Electrochemical Impedance Spectroscopy indicated that all coated samples treated with mechanical treatment showed high corrosion resistance as compared with the untreated sample. It can be concluded that mechanical treatment which is a simple technic can be used as an alternative to improve the corrosion resistance thus reduce the implant and manufacturing cost for biomedical applications.
format Conference or Workshop Item
author A., Shah
Siti Nurul Fasehah, Ismail
Mas Ayu, Hassan
R., Daud
Che Ghani, Che Kob
author_facet A., Shah
Siti Nurul Fasehah, Ismail
Mas Ayu, Hassan
R., Daud
Che Ghani, Che Kob
author_sort A., Shah
title Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application
title_short Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application
title_full Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application
title_fullStr Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application
title_full_unstemmed Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application
title_sort improvement of corrosion resistance of tin coated on titanium alloy for biomedical application
publisher IOP Publishing
publishDate 2021
url http://umpir.ump.edu.my/id/eprint/32008/1/Improvement%20of%20corrosion%20resistance%20of%20tin%20coated%20on%20titanium.pdf
http://umpir.ump.edu.my/id/eprint/32008/
https://doi.org/10.1088/1742-6596/1823/1/012111
_version_ 1724608133197725696