Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application
This work aims to study the effect of mechanical treatment technique on titanium coated with PVD for the enhancement of corrosion resistance for the biomedical implant. First, substrates were coated with TiN via PVD then applied the mechanical treatment through ultrasonic vibration. Results show tha...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
IOP Publishing
2021
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/32008/1/Improvement%20of%20corrosion%20resistance%20of%20tin%20coated%20on%20titanium.pdf http://umpir.ump.edu.my/id/eprint/32008/ https://doi.org/10.1088/1742-6596/1823/1/012111 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaysia Pahang |
Language: | English |
id |
my.ump.umpir.32008 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.320082022-02-11T08:15:52Z http://umpir.ump.edu.my/id/eprint/32008/ Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application A., Shah Siti Nurul Fasehah, Ismail Mas Ayu, Hassan R., Daud Che Ghani, Che Kob T Technology (General) TJ Mechanical engineering and machinery TS Manufactures This work aims to study the effect of mechanical treatment technique on titanium coated with PVD for the enhancement of corrosion resistance for the biomedical implant. First, substrates were coated with TiN via PVD then applied the mechanical treatment through ultrasonic vibration. Results show that all coated samples treated with ultrasonic vibration improve the surface of the coated sample and produce a compact coating as compared with a substrate coated without mechanical treatment. The corrosion test evaluated by Potentiodynamic polarization and Electrochemical Impedance Spectroscopy indicated that all coated samples treated with mechanical treatment showed high corrosion resistance as compared with the untreated sample. It can be concluded that mechanical treatment which is a simple technic can be used as an alternative to improve the corrosion resistance thus reduce the implant and manufacturing cost for biomedical applications. IOP Publishing 2021-03-31 Conference or Workshop Item PeerReviewed pdf en cc_by http://umpir.ump.edu.my/id/eprint/32008/1/Improvement%20of%20corrosion%20resistance%20of%20tin%20coated%20on%20titanium.pdf A., Shah and Siti Nurul Fasehah, Ismail and Mas Ayu, Hassan and R., Daud and Che Ghani, Che Kob (2021) Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application. In: Journal of Physics: Conference Series; 2nd UPY International Conference on Applied Science and Education, UPINCASE 2020, 3 - 4 November 2020 , Yogyakarta, Virtual. pp. 1-10., 1823 (1). ISSN 1742-6588 (print); 1742-6596 (online) https://doi.org/10.1088/1742-6596/1823/1/012111 |
institution |
Universiti Malaysia Pahang |
building |
UMP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang |
content_source |
UMP Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English |
topic |
T Technology (General) TJ Mechanical engineering and machinery TS Manufactures |
spellingShingle |
T Technology (General) TJ Mechanical engineering and machinery TS Manufactures A., Shah Siti Nurul Fasehah, Ismail Mas Ayu, Hassan R., Daud Che Ghani, Che Kob Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application |
description |
This work aims to study the effect of mechanical treatment technique on titanium coated with PVD for the enhancement of corrosion resistance for the biomedical implant. First, substrates were coated with TiN via PVD then applied the mechanical treatment through ultrasonic vibration. Results show that all coated samples treated with ultrasonic vibration improve the surface of the coated sample and produce a compact coating as compared with a substrate coated without mechanical treatment. The corrosion test evaluated by Potentiodynamic polarization and Electrochemical Impedance Spectroscopy indicated that all coated samples treated with mechanical treatment showed high corrosion resistance as compared with the untreated sample. It can be concluded that mechanical treatment which is a simple technic can be used as an alternative to improve the corrosion resistance thus reduce the implant and manufacturing cost for biomedical applications. |
format |
Conference or Workshop Item |
author |
A., Shah Siti Nurul Fasehah, Ismail Mas Ayu, Hassan R., Daud Che Ghani, Che Kob |
author_facet |
A., Shah Siti Nurul Fasehah, Ismail Mas Ayu, Hassan R., Daud Che Ghani, Che Kob |
author_sort |
A., Shah |
title |
Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application |
title_short |
Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application |
title_full |
Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application |
title_fullStr |
Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application |
title_full_unstemmed |
Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application |
title_sort |
improvement of corrosion resistance of tin coated on titanium alloy for biomedical application |
publisher |
IOP Publishing |
publishDate |
2021 |
url |
http://umpir.ump.edu.my/id/eprint/32008/1/Improvement%20of%20corrosion%20resistance%20of%20tin%20coated%20on%20titanium.pdf http://umpir.ump.edu.my/id/eprint/32008/ https://doi.org/10.1088/1742-6596/1823/1/012111 |
_version_ |
1724608133197725696 |