Flow and heat transfer simulation analysis of 3D compact heat exchanger

One of the most common heat exchangers (HEs) utilized in the industry is a compact heat exchanger due to its superior advantage over other types of heat exchangers. Various geometric (fin spacing, tube inclination angle, etc) and process (such as flow velocity, temperature, etc) parameters affect th...

Full description

Saved in:
Bibliographic Details
Main Authors: G., Sashwin Nair, Oumer, A. N., Azizuddin, Abd Aziz, Siregar, Januar Parlaungan
Format: Article
Language:English
Published: Akademi Baru 2021
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/32900/1/8.%20Flow%20and%20heat%20transfer%20simulation%20analysis%20of%203D%20compact%20heat%20exchanger.pdf
http://umpir.ump.edu.my/id/eprint/32900/
https://doi.org/10.37934/arfmts.88.3.7187
https://doi.org/10.37934/arfmts.88.3.7187
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaysia Pahang Al-Sultan Abdullah
Language: English
id my.ump.umpir.32900
record_format eprints
spelling my.ump.umpir.329002022-05-19T02:35:58Z http://umpir.ump.edu.my/id/eprint/32900/ Flow and heat transfer simulation analysis of 3D compact heat exchanger G., Sashwin Nair Oumer, A. N. Azizuddin, Abd Aziz Siregar, Januar Parlaungan TJ Mechanical engineering and machinery One of the most common heat exchangers (HEs) utilized in the industry is a compact heat exchanger due to its superior advantage over other types of heat exchangers. Various geometric (fin spacing, tube inclination angle, etc) and process (such as flow velocity, temperature, etc) parameters affect the performance of such compact HEs. The objective of this paper is to investigate the effects of fin spacing, tube inclination angle, and airflow velocity for both tube configurations which are inline and staggered arrangements on heat transfer and pressure drop performance of fin-and-tube HEs. A three-dimensional (3D) numerical method with the aid of Ansys FLUENT software was carried out for the laminar flow condition. Based on the obtained results, the highest average heat transfer coefficient was observed at 120° for both tube arrangements while the lowest average pressure drop penalty is at 30°. Therefore, the recommended inclination angle when high heat transfer is needed is at 120° while if the pumping power is the major problem, 30 °or 150° is recommended. Akademi Baru 2021 Article PeerReviewed pdf en cc_by_nc_4 http://umpir.ump.edu.my/id/eprint/32900/1/8.%20Flow%20and%20heat%20transfer%20simulation%20analysis%20of%203D%20compact%20heat%20exchanger.pdf G., Sashwin Nair and Oumer, A. N. and Azizuddin, Abd Aziz and Siregar, Januar Parlaungan (2021) Flow and heat transfer simulation analysis of 3D compact heat exchanger. Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 88 (3). pp. 71-87. ISSN 2289-7879. (Published) https://doi.org/10.37934/arfmts.88.3.7187 https://doi.org/10.37934/arfmts.88.3.7187
institution Universiti Malaysia Pahang Al-Sultan Abdullah
building UMPSA Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang Al-Sultan Abdullah
content_source UMPSA Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
G., Sashwin Nair
Oumer, A. N.
Azizuddin, Abd Aziz
Siregar, Januar Parlaungan
Flow and heat transfer simulation analysis of 3D compact heat exchanger
description One of the most common heat exchangers (HEs) utilized in the industry is a compact heat exchanger due to its superior advantage over other types of heat exchangers. Various geometric (fin spacing, tube inclination angle, etc) and process (such as flow velocity, temperature, etc) parameters affect the performance of such compact HEs. The objective of this paper is to investigate the effects of fin spacing, tube inclination angle, and airflow velocity for both tube configurations which are inline and staggered arrangements on heat transfer and pressure drop performance of fin-and-tube HEs. A three-dimensional (3D) numerical method with the aid of Ansys FLUENT software was carried out for the laminar flow condition. Based on the obtained results, the highest average heat transfer coefficient was observed at 120° for both tube arrangements while the lowest average pressure drop penalty is at 30°. Therefore, the recommended inclination angle when high heat transfer is needed is at 120° while if the pumping power is the major problem, 30 °or 150° is recommended.
format Article
author G., Sashwin Nair
Oumer, A. N.
Azizuddin, Abd Aziz
Siregar, Januar Parlaungan
author_facet G., Sashwin Nair
Oumer, A. N.
Azizuddin, Abd Aziz
Siregar, Januar Parlaungan
author_sort G., Sashwin Nair
title Flow and heat transfer simulation analysis of 3D compact heat exchanger
title_short Flow and heat transfer simulation analysis of 3D compact heat exchanger
title_full Flow and heat transfer simulation analysis of 3D compact heat exchanger
title_fullStr Flow and heat transfer simulation analysis of 3D compact heat exchanger
title_full_unstemmed Flow and heat transfer simulation analysis of 3D compact heat exchanger
title_sort flow and heat transfer simulation analysis of 3d compact heat exchanger
publisher Akademi Baru
publishDate 2021
url http://umpir.ump.edu.my/id/eprint/32900/1/8.%20Flow%20and%20heat%20transfer%20simulation%20analysis%20of%203D%20compact%20heat%20exchanger.pdf
http://umpir.ump.edu.my/id/eprint/32900/
https://doi.org/10.37934/arfmts.88.3.7187
https://doi.org/10.37934/arfmts.88.3.7187
_version_ 1822922350888222720