A mathematical model of a brushed DC motor system

Mathematical model has been proposed for some system that involves a brushed DC motor and it is widely used in industry. Brushed DC motor ideals for applications with a low- torque, manage to change pace or speed and it is widely used in many applications such as x-y table positioning system, convey...

Full description

Saved in:
Bibliographic Details
Main Authors: N. N. A., Rahman, Nafrizuan, Mat Yahya
Format: Article
Language:English
Published: Penerbit UMP 2021
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/32913/1/A%20mathematical%20model%20of%20a%20brushed%20DC%20motor%20system.pdf
http://umpir.ump.edu.my/id/eprint/32913/
https://doi.org/10.15282/daam.v2i2.6830
https://doi.org/10.15282/daam.v2i2.6830
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaysia Pahang
Language: English
id my.ump.umpir.32913
record_format eprints
spelling my.ump.umpir.329132022-09-06T01:34:31Z http://umpir.ump.edu.my/id/eprint/32913/ A mathematical model of a brushed DC motor system N. N. A., Rahman Nafrizuan, Mat Yahya QA Mathematics TJ Mechanical engineering and machinery Mathematical model has been proposed for some system that involves a brushed DC motor and it is widely used in industry. Brushed DC motor ideals for applications with a low- torque, manage to change pace or speed and it is widely used in many applications such as x-y table positioning system, conveyor systems and other system that required to use the features that brushed DC motor have. Mathematical model of brushed DC motor in order to verify the performance of the DC motor. In this paper, mathematical model of brushed DC motor will be derived from a brushed DC motor circuit that consist of two parts that are electrical and mechanical part. To validate the functionality of mathematical model, the performance of the brushed DC motor without any controller will be compared with the brushed DC motor with the presence of PI-PD controller that will be tuned by trial-and-error method. Performances of both brushed DC motor with and without controller will be compared in terms of transient response which are, rise time, Tr, settling time, Ts, steady state error, ess and lastly percentage overshoot. At the end of the study, the brushed DC motor with PI-PD controller show a better performance compared to the brushed DC motor without any controller. Penerbit UMP 2021-12-06 Article PeerReviewed pdf en cc_by_nc_nd_4 http://umpir.ump.edu.my/id/eprint/32913/1/A%20mathematical%20model%20of%20a%20brushed%20DC%20motor%20system.pdf N. N. A., Rahman and Nafrizuan, Mat Yahya (2021) A mathematical model of a brushed DC motor system. Data Analytics and Applied Mathematics (DAAM), 2 (2). pp. 60-68. ISSN 2773-4854 https://doi.org/10.15282/daam.v2i2.6830 https://doi.org/10.15282/daam.v2i2.6830
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic QA Mathematics
TJ Mechanical engineering and machinery
spellingShingle QA Mathematics
TJ Mechanical engineering and machinery
N. N. A., Rahman
Nafrizuan, Mat Yahya
A mathematical model of a brushed DC motor system
description Mathematical model has been proposed for some system that involves a brushed DC motor and it is widely used in industry. Brushed DC motor ideals for applications with a low- torque, manage to change pace or speed and it is widely used in many applications such as x-y table positioning system, conveyor systems and other system that required to use the features that brushed DC motor have. Mathematical model of brushed DC motor in order to verify the performance of the DC motor. In this paper, mathematical model of brushed DC motor will be derived from a brushed DC motor circuit that consist of two parts that are electrical and mechanical part. To validate the functionality of mathematical model, the performance of the brushed DC motor without any controller will be compared with the brushed DC motor with the presence of PI-PD controller that will be tuned by trial-and-error method. Performances of both brushed DC motor with and without controller will be compared in terms of transient response which are, rise time, Tr, settling time, Ts, steady state error, ess and lastly percentage overshoot. At the end of the study, the brushed DC motor with PI-PD controller show a better performance compared to the brushed DC motor without any controller.
format Article
author N. N. A., Rahman
Nafrizuan, Mat Yahya
author_facet N. N. A., Rahman
Nafrizuan, Mat Yahya
author_sort N. N. A., Rahman
title A mathematical model of a brushed DC motor system
title_short A mathematical model of a brushed DC motor system
title_full A mathematical model of a brushed DC motor system
title_fullStr A mathematical model of a brushed DC motor system
title_full_unstemmed A mathematical model of a brushed DC motor system
title_sort mathematical model of a brushed dc motor system
publisher Penerbit UMP
publishDate 2021
url http://umpir.ump.edu.my/id/eprint/32913/1/A%20mathematical%20model%20of%20a%20brushed%20DC%20motor%20system.pdf
http://umpir.ump.edu.my/id/eprint/32913/
https://doi.org/10.15282/daam.v2i2.6830
https://doi.org/10.15282/daam.v2i2.6830
_version_ 1744353869744308224