The Stiffness of Steel-Wood-Steel Connection Loaded Parallel to the Grain

In Eurocode 5, the stiffness equation for bolted steel-wood-steel is stated as a function of wood density and fastener diameter only. In this research, an experimental study on various configurations of tested bolted steel-wood-steel (SWS) connections has been undertaken to predict the initial stiff...

Full description

Saved in:
Bibliographic Details
Main Authors: Nur Liza, Rahim, Raftery, Gary, Quenneville, Pierre, Doh, Shu Ing, Nabialek, Marcin, Putra Jaya, Ramadhansyah, Norlia, Mohamad Ibrahim, Mohd Mustafa Al Bakri, Abdullah, Śliwa, Agata
Format: Article
Language:English
Published: Polish Academy of Sciences 2022
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/34569/1/The%20stiffness%20of%20steel-wood-steel%20connection%20loaded%20parallel%20to%20the%20grain.pdf
http://umpir.ump.edu.my/id/eprint/34569/
https://doi.org/10.24425/ace.2022.140628
https://doi.org/10.24425/ace.2022.140628
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaysia Pahang
Language: English
id my.ump.umpir.34569
record_format eprints
spelling my.ump.umpir.345692022-07-29T01:11:58Z http://umpir.ump.edu.my/id/eprint/34569/ The Stiffness of Steel-Wood-Steel Connection Loaded Parallel to the Grain Nur Liza, Rahim Raftery, Gary Quenneville, Pierre Doh, Shu Ing Nabialek, Marcin Putra Jaya, Ramadhansyah Norlia, Mohamad Ibrahim Mohd Mustafa Al Bakri, Abdullah Śliwa, Agata TH Building construction In Eurocode 5, the stiffness equation for bolted steel-wood-steel is stated as a function of wood density and fastener diameter only. In this research, an experimental study on various configurations of tested bolted steel-wood-steel (SWS) connections has been undertaken to predict the initial stiffness of each connection. In order to validate the Eurocode 5 stiffness equation, tests on 50 timber specimens (40 glued laminated timbers and 10 laminated veneer lumbers (LVL)) with steel plates were undertaken. The number of bolts was kept similar and the connector diameter, timber thickness, and wood density were varied. The results obtained in the experimental tests are compared with those obtained from the Eurocode 5 stiffness equation. From the analysis, it is signified that the stiffness equation specified in Eurocode 5 for bolted SWS connections does not adequately predict the initial stiffness. The results from Eurocode 5 stiffness equation are very far from the experimental values. The ratio of stiffness equation to experimental results ranges from 3.48 to 4.20, with the average at 3.77, where the equation overpredicted the experimental stiffness value for the connection. There is a need to consider or incorporated other parameters such as geometric configurations in Eurocode 5 stiffness equation to improve the ratio with the experimental data. Polish Academy of Sciences 2022 Article PeerReviewed pdf en cc_by_nc_nd_4 http://umpir.ump.edu.my/id/eprint/34569/1/The%20stiffness%20of%20steel-wood-steel%20connection%20loaded%20parallel%20to%20the%20grain.pdf Nur Liza, Rahim and Raftery, Gary and Quenneville, Pierre and Doh, Shu Ing and Nabialek, Marcin and Putra Jaya, Ramadhansyah and Norlia, Mohamad Ibrahim and Mohd Mustafa Al Bakri, Abdullah and Śliwa, Agata (2022) The Stiffness of Steel-Wood-Steel Connection Loaded Parallel to the Grain. Archives of Civil Engineering, 68 (2). pp. 37-50. ISSN 1230-2945 https://doi.org/10.24425/ace.2022.140628 https://doi.org/10.24425/ace.2022.140628
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TH Building construction
spellingShingle TH Building construction
Nur Liza, Rahim
Raftery, Gary
Quenneville, Pierre
Doh, Shu Ing
Nabialek, Marcin
Putra Jaya, Ramadhansyah
Norlia, Mohamad Ibrahim
Mohd Mustafa Al Bakri, Abdullah
Śliwa, Agata
The Stiffness of Steel-Wood-Steel Connection Loaded Parallel to the Grain
description In Eurocode 5, the stiffness equation for bolted steel-wood-steel is stated as a function of wood density and fastener diameter only. In this research, an experimental study on various configurations of tested bolted steel-wood-steel (SWS) connections has been undertaken to predict the initial stiffness of each connection. In order to validate the Eurocode 5 stiffness equation, tests on 50 timber specimens (40 glued laminated timbers and 10 laminated veneer lumbers (LVL)) with steel plates were undertaken. The number of bolts was kept similar and the connector diameter, timber thickness, and wood density were varied. The results obtained in the experimental tests are compared with those obtained from the Eurocode 5 stiffness equation. From the analysis, it is signified that the stiffness equation specified in Eurocode 5 for bolted SWS connections does not adequately predict the initial stiffness. The results from Eurocode 5 stiffness equation are very far from the experimental values. The ratio of stiffness equation to experimental results ranges from 3.48 to 4.20, with the average at 3.77, where the equation overpredicted the experimental stiffness value for the connection. There is a need to consider or incorporated other parameters such as geometric configurations in Eurocode 5 stiffness equation to improve the ratio with the experimental data.
format Article
author Nur Liza, Rahim
Raftery, Gary
Quenneville, Pierre
Doh, Shu Ing
Nabialek, Marcin
Putra Jaya, Ramadhansyah
Norlia, Mohamad Ibrahim
Mohd Mustafa Al Bakri, Abdullah
Śliwa, Agata
author_facet Nur Liza, Rahim
Raftery, Gary
Quenneville, Pierre
Doh, Shu Ing
Nabialek, Marcin
Putra Jaya, Ramadhansyah
Norlia, Mohamad Ibrahim
Mohd Mustafa Al Bakri, Abdullah
Śliwa, Agata
author_sort Nur Liza, Rahim
title The Stiffness of Steel-Wood-Steel Connection Loaded Parallel to the Grain
title_short The Stiffness of Steel-Wood-Steel Connection Loaded Parallel to the Grain
title_full The Stiffness of Steel-Wood-Steel Connection Loaded Parallel to the Grain
title_fullStr The Stiffness of Steel-Wood-Steel Connection Loaded Parallel to the Grain
title_full_unstemmed The Stiffness of Steel-Wood-Steel Connection Loaded Parallel to the Grain
title_sort stiffness of steel-wood-steel connection loaded parallel to the grain
publisher Polish Academy of Sciences
publishDate 2022
url http://umpir.ump.edu.my/id/eprint/34569/1/The%20stiffness%20of%20steel-wood-steel%20connection%20loaded%20parallel%20to%20the%20grain.pdf
http://umpir.ump.edu.my/id/eprint/34569/
https://doi.org/10.24425/ace.2022.140628
https://doi.org/10.24425/ace.2022.140628
_version_ 1739828262789447680