Computational study of hemodynamics analysis between mri measurement and cfd simulation on segmented patient-specific cerebral aneurysm model

The implementation of computational fluid dynamics (CFD) analysis was extensively performed to investigate the hemodynamics using segmented patient-specific cerebral aneurysm model geometry reconstructed from a medical image in this research. According to previous studies, the low-resolution magneti...

Full description

Saved in:
Bibliographic Details
Main Author: Lim, Sheh Hong
Format: Thesis
Language:English
Published: 2021
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/34763/1/Computational%20study%20of%20hemodynamics%20analysis%20between%20mri%20measurement%20and%20cfd%20simulation.wm.pdf
http://umpir.ump.edu.my/id/eprint/34763/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaysia Pahang
Language: English
id my.ump.umpir.34763
record_format eprints
spelling my.ump.umpir.347632023-05-23T04:56:37Z http://umpir.ump.edu.my/id/eprint/34763/ Computational study of hemodynamics analysis between mri measurement and cfd simulation on segmented patient-specific cerebral aneurysm model Lim, Sheh Hong T Technology (General) TA Engineering (General). Civil engineering (General) The implementation of computational fluid dynamics (CFD) analysis was extensively performed to investigate the hemodynamics using segmented patient-specific cerebral aneurysm model geometry reconstructed from a medical image in this research. According to previous studies, the low-resolution magnetic resonance imaging (MRI) medical image produces a high measurement error and leads to inaccurate hemodynamics approximations with a large velocity difference of approximately 40 % between MRI measurement and CFD simulation. Besides, setting patient-specific boundary conditions before CFD analysis is critical, but there is no unified rule, especially for the setup of model geometry with bifurcation, which requires multiple outlet boundaries. Therefore, this study investigated the extracted model geometry with different threshold coefficients, 2021-11 Thesis NonPeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/34763/1/Computational%20study%20of%20hemodynamics%20analysis%20between%20mri%20measurement%20and%20cfd%20simulation.wm.pdf Lim, Sheh Hong (2021) Computational study of hemodynamics analysis between mri measurement and cfd simulation on segmented patient-specific cerebral aneurysm model. Masters thesis, Universiti Malaysia Pahang (Contributors, Thesis advisor: Mohd Adib, Mohd Azrul Hisham).
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic T Technology (General)
TA Engineering (General). Civil engineering (General)
spellingShingle T Technology (General)
TA Engineering (General). Civil engineering (General)
Lim, Sheh Hong
Computational study of hemodynamics analysis between mri measurement and cfd simulation on segmented patient-specific cerebral aneurysm model
description The implementation of computational fluid dynamics (CFD) analysis was extensively performed to investigate the hemodynamics using segmented patient-specific cerebral aneurysm model geometry reconstructed from a medical image in this research. According to previous studies, the low-resolution magnetic resonance imaging (MRI) medical image produces a high measurement error and leads to inaccurate hemodynamics approximations with a large velocity difference of approximately 40 % between MRI measurement and CFD simulation. Besides, setting patient-specific boundary conditions before CFD analysis is critical, but there is no unified rule, especially for the setup of model geometry with bifurcation, which requires multiple outlet boundaries. Therefore, this study investigated the extracted model geometry with different threshold coefficients,
format Thesis
author Lim, Sheh Hong
author_facet Lim, Sheh Hong
author_sort Lim, Sheh Hong
title Computational study of hemodynamics analysis between mri measurement and cfd simulation on segmented patient-specific cerebral aneurysm model
title_short Computational study of hemodynamics analysis between mri measurement and cfd simulation on segmented patient-specific cerebral aneurysm model
title_full Computational study of hemodynamics analysis between mri measurement and cfd simulation on segmented patient-specific cerebral aneurysm model
title_fullStr Computational study of hemodynamics analysis between mri measurement and cfd simulation on segmented patient-specific cerebral aneurysm model
title_full_unstemmed Computational study of hemodynamics analysis between mri measurement and cfd simulation on segmented patient-specific cerebral aneurysm model
title_sort computational study of hemodynamics analysis between mri measurement and cfd simulation on segmented patient-specific cerebral aneurysm model
publishDate 2021
url http://umpir.ump.edu.my/id/eprint/34763/1/Computational%20study%20of%20hemodynamics%20analysis%20between%20mri%20measurement%20and%20cfd%20simulation.wm.pdf
http://umpir.ump.edu.my/id/eprint/34763/
_version_ 1768006860992937984