Optimal nuclear trigeneration system considering life cycle costing
A nuclear reactor can generate a large amount of high-temperature waste heat, which can be recovered to produce simultaneous electricity, heating and cooling, known as a trigeneration system. Trigeneration System Cascade Analysis is a methodology based on Pinch Analysis to optimise a centralised tri...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English English |
Published: |
Elsevier Ltd
2022
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/40190/1/Optimal%20nuclear%20trigeneration%20system%20considering%20life.pdf http://umpir.ump.edu.my/id/eprint/40190/2/Optimal%20nuclear%20trigeneration%20system%20considering%20life%20cycle%20costing_ABS.pdf http://umpir.ump.edu.my/id/eprint/40190/ https://doi.org/10.1016/j.jclepro.2022.133399 https://doi.org/10.1016/j.jclepro.2022.133399 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaysia Pahang Al-Sultan Abdullah |
Language: | English English |
id |
my.ump.umpir.40190 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.401902024-02-08T06:41:31Z http://umpir.ump.edu.my/id/eprint/40190/ Optimal nuclear trigeneration system considering life cycle costing Khairulnadzmi, Jamaluddin Sharifah Rafidah, Wan Alwi Zainuddin, Abdul Manan Khaidzir, Hamzah Klemeš, Jiří Jaromír Roziah, Zailan T Technology (General) TA Engineering (General). Civil engineering (General) A nuclear reactor can generate a large amount of high-temperature waste heat, which can be recovered to produce simultaneous electricity, heating and cooling, known as a trigeneration system. Trigeneration System Cascade Analysis is a methodology based on Pinch Analysis to optimise a centralised trigeneration system in various energy ratings in demands. However, the previous study does not consider a complete life cycle costing in the Trigeneration System Cascade Analysis. The methodology consists of three main parts, which are data extraction, development of Trigeneration System Cascade Analysis, and calculations of the life cycle costing. In this analysis, a centralised Pressurised Water Reactor, which is the most commonly used nuclear reactor in the world, is applied in a trigeneration mode in three different industrial plants. Based on the results of the case study, an optimal Pressurised Water Reactor trigeneration system is obtained where the total thermal energy required is 1,102.25 MW or translated into 26.5 GWh/d. The Equivalent Annual Cost for the case study, on the other hand, showed the centralised Pressurised Water Reactor trigeneration system requires 1.89 × 1011 USD/y for maintaining, operating, constructing, and disposing of the overall Pressurised Water Reactor trigeneration system. The maintenance cost is the highest percentage which constitutes 51.3% of the overall cost. Comparisons between normal conditions, and planned and unplanned shutdowns are also conducted, and the results show that Equivalent Annual Costs of planned and unplanned shutdowns required an additional 1.4 MUSD and 0.5 MUSD to support the deficit energy during shutdowns. The implementation of the full life cycle costing during the normal conditions planned and unplanned shutdowns of the Pressurized Water Reactor trigeneration system gives a proper projection of the cash flows that can create an economic model that reflects all the project realisation conditions. Elsevier Ltd 2022-10-10 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/40190/1/Optimal%20nuclear%20trigeneration%20system%20considering%20life.pdf pdf en http://umpir.ump.edu.my/id/eprint/40190/2/Optimal%20nuclear%20trigeneration%20system%20considering%20life%20cycle%20costing_ABS.pdf Khairulnadzmi, Jamaluddin and Sharifah Rafidah, Wan Alwi and Zainuddin, Abdul Manan and Khaidzir, Hamzah and Klemeš, Jiří Jaromír and Roziah, Zailan (2022) Optimal nuclear trigeneration system considering life cycle costing. Journal of Cleaner Production, 370 (133399). pp. 1-20. ISSN 0959-6526. (Published) https://doi.org/10.1016/j.jclepro.2022.133399 https://doi.org/10.1016/j.jclepro.2022.133399 |
institution |
Universiti Malaysia Pahang Al-Sultan Abdullah |
building |
UMPSA Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang Al-Sultan Abdullah |
content_source |
UMPSA Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English English |
topic |
T Technology (General) TA Engineering (General). Civil engineering (General) |
spellingShingle |
T Technology (General) TA Engineering (General). Civil engineering (General) Khairulnadzmi, Jamaluddin Sharifah Rafidah, Wan Alwi Zainuddin, Abdul Manan Khaidzir, Hamzah Klemeš, Jiří Jaromír Roziah, Zailan Optimal nuclear trigeneration system considering life cycle costing |
description |
A nuclear reactor can generate a large amount of high-temperature waste heat, which can be recovered to produce simultaneous electricity, heating and cooling, known as a trigeneration system. Trigeneration System Cascade Analysis is a methodology based on Pinch Analysis to optimise a centralised trigeneration system in various energy ratings in demands. However, the previous study does not consider a complete life cycle costing in the Trigeneration System Cascade Analysis. The methodology consists of three main parts, which are data extraction, development of Trigeneration System Cascade Analysis, and calculations of the life cycle costing. In this analysis, a centralised Pressurised Water Reactor, which is the most commonly used nuclear reactor in the world, is applied in a trigeneration mode in three different industrial plants. Based on the results of the case study, an optimal Pressurised Water Reactor trigeneration system is obtained where the total thermal energy required is 1,102.25 MW or translated into 26.5 GWh/d. The Equivalent Annual Cost for the case study, on the other hand, showed the centralised Pressurised Water Reactor trigeneration system requires 1.89 × 1011 USD/y for maintaining, operating, constructing, and disposing of the overall Pressurised Water Reactor trigeneration system. The maintenance cost is the highest percentage which constitutes 51.3% of the overall cost. Comparisons between normal conditions, and planned and unplanned shutdowns are also conducted, and the results show that Equivalent Annual Costs of planned and unplanned shutdowns required an additional 1.4 MUSD and 0.5 MUSD to support the deficit energy during shutdowns. The implementation of the full life cycle costing during the normal conditions planned and unplanned shutdowns of the Pressurized Water Reactor trigeneration system gives a proper projection of the cash flows that can create an economic model that reflects all the project realisation conditions. |
format |
Article |
author |
Khairulnadzmi, Jamaluddin Sharifah Rafidah, Wan Alwi Zainuddin, Abdul Manan Khaidzir, Hamzah Klemeš, Jiří Jaromír Roziah, Zailan |
author_facet |
Khairulnadzmi, Jamaluddin Sharifah Rafidah, Wan Alwi Zainuddin, Abdul Manan Khaidzir, Hamzah Klemeš, Jiří Jaromír Roziah, Zailan |
author_sort |
Khairulnadzmi, Jamaluddin |
title |
Optimal nuclear trigeneration system considering life cycle costing |
title_short |
Optimal nuclear trigeneration system considering life cycle costing |
title_full |
Optimal nuclear trigeneration system considering life cycle costing |
title_fullStr |
Optimal nuclear trigeneration system considering life cycle costing |
title_full_unstemmed |
Optimal nuclear trigeneration system considering life cycle costing |
title_sort |
optimal nuclear trigeneration system considering life cycle costing |
publisher |
Elsevier Ltd |
publishDate |
2022 |
url |
http://umpir.ump.edu.my/id/eprint/40190/1/Optimal%20nuclear%20trigeneration%20system%20considering%20life.pdf http://umpir.ump.edu.my/id/eprint/40190/2/Optimal%20nuclear%20trigeneration%20system%20considering%20life%20cycle%20costing_ABS.pdf http://umpir.ump.edu.my/id/eprint/40190/ https://doi.org/10.1016/j.jclepro.2022.133399 https://doi.org/10.1016/j.jclepro.2022.133399 |
_version_ |
1822924123876098048 |