Analysis of the Performances of Biogas-Fuelled Micro Gas Turbine Cogeneration Systems (MGT-CGSs) in Middle- and Small-Scale Sewage Treatment Plants: Comparison of Performances and Optimization of Mgts with Various Electrical Power Outputs

The suitable size (electricity output capacity) of micro gas turbine cogeneration systems (MGT-CGSs) depending on scale of the sewage treatment plant was investigated. Since heat demand of the plant is affected by ambient temperature, performance under three typical ambient temperature conditions wa...

Full description

Saved in:
Bibliographic Details
Main Authors: F., Basrawi, Takanobu, Yamada, Kimio, Nakanish, Hideaki, Katsumata
Format: Article
Language:English
Published: Elsevier Ltd. 2012
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/6870/1/Analysis_of_the_performances_of_biogas-fuelled_micro_gas_turbine_cogeneration_systems_%28MGT-CGSs%29_in_middle-_and_small-scale_sewage_treatment_plants_Comparison_of_performances_and_optimization_of_MGTs_with_various_electrical.pdf
http://umpir.ump.edu.my/id/eprint/6870/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaysia Pahang
Language: English
id my.ump.umpir.6870
record_format eprints
spelling my.ump.umpir.68702015-09-09T06:25:28Z http://umpir.ump.edu.my/id/eprint/6870/ Analysis of the Performances of Biogas-Fuelled Micro Gas Turbine Cogeneration Systems (MGT-CGSs) in Middle- and Small-Scale Sewage Treatment Plants: Comparison of Performances and Optimization of Mgts with Various Electrical Power Outputs F., Basrawi Takanobu, Yamada Kimio, Nakanish Hideaki, Katsumata TJ Mechanical engineering and machinery The suitable size (electricity output capacity) of micro gas turbine cogeneration systems (MGT-CGSs) depending on scale of the sewage treatment plant was investigated. Since heat demand of the plant is affected by ambient temperature, performance under three typical ambient temperature conditions was investigated. Considering operation of the MGT-CGS under various loads and efficiency of the MGT-CGS under a partial load condition, the optimal combination of MGT-CGSs (MGT-Combination) with different sizes, 30 kW, 65 kW and 200 kW, was also proposed. An actual middle-scale plant was adopted as the analysis model, and it was scaled down to 0.50 and 0.25 in cases of smaller scale. Excluding MGT Combination, it was found that the MGT that has approximately the same fuel energy input under full load as the biogas energy produced in the plant has the highest efficiency. However, in the case of heat demand of the plant varying throughout the year such as the operation in a cold region, partial load operation will be frequent and efficiency will decrease. Furthermore, MGT-Combination has the highest efficiency but its efficiency will be the same as that of the other MGT-CGSs when only comparatively constant operation is required throughout the year such as operation in a tropical region. Elsevier Ltd. 2012 Article PeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/6870/1/Analysis_of_the_performances_of_biogas-fuelled_micro_gas_turbine_cogeneration_systems_%28MGT-CGSs%29_in_middle-_and_small-scale_sewage_treatment_plants_Comparison_of_performances_and_optimization_of_MGTs_with_various_electrical.pdf F., Basrawi and Takanobu, Yamada and Kimio, Nakanish and Hideaki, Katsumata (2012) Analysis of the Performances of Biogas-Fuelled Micro Gas Turbine Cogeneration Systems (MGT-CGSs) in Middle- and Small-Scale Sewage Treatment Plants: Comparison of Performances and Optimization of Mgts with Various Electrical Power Outputs. Energy, 38. pp. 291-304. ISSN 0360-5442 doi:10.1016/j.energy.2011.12.001
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
F., Basrawi
Takanobu, Yamada
Kimio, Nakanish
Hideaki, Katsumata
Analysis of the Performances of Biogas-Fuelled Micro Gas Turbine Cogeneration Systems (MGT-CGSs) in Middle- and Small-Scale Sewage Treatment Plants: Comparison of Performances and Optimization of Mgts with Various Electrical Power Outputs
description The suitable size (electricity output capacity) of micro gas turbine cogeneration systems (MGT-CGSs) depending on scale of the sewage treatment plant was investigated. Since heat demand of the plant is affected by ambient temperature, performance under three typical ambient temperature conditions was investigated. Considering operation of the MGT-CGS under various loads and efficiency of the MGT-CGS under a partial load condition, the optimal combination of MGT-CGSs (MGT-Combination) with different sizes, 30 kW, 65 kW and 200 kW, was also proposed. An actual middle-scale plant was adopted as the analysis model, and it was scaled down to 0.50 and 0.25 in cases of smaller scale. Excluding MGT Combination, it was found that the MGT that has approximately the same fuel energy input under full load as the biogas energy produced in the plant has the highest efficiency. However, in the case of heat demand of the plant varying throughout the year such as the operation in a cold region, partial load operation will be frequent and efficiency will decrease. Furthermore, MGT-Combination has the highest efficiency but its efficiency will be the same as that of the other MGT-CGSs when only comparatively constant operation is required throughout the year such as operation in a tropical region.
format Article
author F., Basrawi
Takanobu, Yamada
Kimio, Nakanish
Hideaki, Katsumata
author_facet F., Basrawi
Takanobu, Yamada
Kimio, Nakanish
Hideaki, Katsumata
author_sort F., Basrawi
title Analysis of the Performances of Biogas-Fuelled Micro Gas Turbine Cogeneration Systems (MGT-CGSs) in Middle- and Small-Scale Sewage Treatment Plants: Comparison of Performances and Optimization of Mgts with Various Electrical Power Outputs
title_short Analysis of the Performances of Biogas-Fuelled Micro Gas Turbine Cogeneration Systems (MGT-CGSs) in Middle- and Small-Scale Sewage Treatment Plants: Comparison of Performances and Optimization of Mgts with Various Electrical Power Outputs
title_full Analysis of the Performances of Biogas-Fuelled Micro Gas Turbine Cogeneration Systems (MGT-CGSs) in Middle- and Small-Scale Sewage Treatment Plants: Comparison of Performances and Optimization of Mgts with Various Electrical Power Outputs
title_fullStr Analysis of the Performances of Biogas-Fuelled Micro Gas Turbine Cogeneration Systems (MGT-CGSs) in Middle- and Small-Scale Sewage Treatment Plants: Comparison of Performances and Optimization of Mgts with Various Electrical Power Outputs
title_full_unstemmed Analysis of the Performances of Biogas-Fuelled Micro Gas Turbine Cogeneration Systems (MGT-CGSs) in Middle- and Small-Scale Sewage Treatment Plants: Comparison of Performances and Optimization of Mgts with Various Electrical Power Outputs
title_sort analysis of the performances of biogas-fuelled micro gas turbine cogeneration systems (mgt-cgss) in middle- and small-scale sewage treatment plants: comparison of performances and optimization of mgts with various electrical power outputs
publisher Elsevier Ltd.
publishDate 2012
url http://umpir.ump.edu.my/id/eprint/6870/1/Analysis_of_the_performances_of_biogas-fuelled_micro_gas_turbine_cogeneration_systems_%28MGT-CGSs%29_in_middle-_and_small-scale_sewage_treatment_plants_Comparison_of_performances_and_optimization_of_MGTs_with_various_electrical.pdf
http://umpir.ump.edu.my/id/eprint/6870/
_version_ 1643665487265005568