Electrode Wear Rate of Graphite Electrodes during Electrical Discharge Machining Processes on Titanium Alloy Ti-5Al-2.5Sn
The proper selection of machining parameters can result in better machining performance in the electrical discharge machining process. However, this job is not always easy since the phenomena occurring between the electrodes in EDM are not yet fully understood. This study reports the development of...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universiti Malaysia Pahang
2014
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/8174/1/26_Khan_et_al.pdf http://umpir.ump.edu.my/id/eprint/8174/ http://dx.doi.org/10.15282/ijame.9.2013.26.0148 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaysia Pahang |
Language: | English |
id |
my.ump.umpir.8174 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.81742018-01-25T02:56:29Z http://umpir.ump.edu.my/id/eprint/8174/ Electrode Wear Rate of Graphite Electrodes during Electrical Discharge Machining Processes on Titanium Alloy Ti-5Al-2.5Sn Khan, Md. Ashikur Rahman M. M., Rahman K., Kadirgama TJ Mechanical engineering and machinery The proper selection of machining parameters can result in better machining performance in the electrical discharge machining process. However, this job is not always easy since the phenomena occurring between the electrodes in EDM are not yet fully understood. This study reports the development of a comprehensive mathematical model for the electrode wear rate (EWR) of a graphite tool in EDM on Ti-5Al-2.5Sn alloy, which has not yet been presented. Experiments for positive polarity of the graphite electrode, based on design of experiment (DOE), are first conducted. Modeling and analysis are carried out through the response surface methodology, utilizing the experimental results. A confirmation test is also executed to confirm the validity and the accuracy of the mathematical model developed. The confirmation test exhibits an average error of less than 6%. Negative electrode wear is evidenced for particular settings. The combination of 15A peak current, 350µs pulse-on time, 180µs pulse-off time and 95V servo-voltage and positive polarity causes negative tool wear. It is apparent that the developed model can evaluate electrode wear rate accurately and successfully. Universiti Malaysia Pahang 2014-06-30 Article PeerReviewed application/pdf en cc_by http://umpir.ump.edu.my/id/eprint/8174/1/26_Khan_et_al.pdf Khan, Md. Ashikur Rahman and M. M., Rahman and K., Kadirgama (2014) Electrode Wear Rate of Graphite Electrodes during Electrical Discharge Machining Processes on Titanium Alloy Ti-5Al-2.5Sn. International Journal of Automotive and Mechanical Engineering (IJAME), 9. pp. 1782-1792. ISSN 1985-9325(Print); 2180-1606 (Online) http://dx.doi.org/10.15282/ijame.9.2013.26.0148 DOI: 10.15282/ijame.9.2013.26.0148 |
institution |
Universiti Malaysia Pahang |
building |
UMP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang |
content_source |
UMP Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English |
topic |
TJ Mechanical engineering and machinery |
spellingShingle |
TJ Mechanical engineering and machinery Khan, Md. Ashikur Rahman M. M., Rahman K., Kadirgama Electrode Wear Rate of Graphite Electrodes during Electrical Discharge Machining Processes on Titanium Alloy Ti-5Al-2.5Sn |
description |
The proper selection of machining parameters can result in better machining performance in the electrical discharge machining process. However, this job is not always easy since the phenomena occurring between the electrodes in EDM are not yet fully understood. This study reports the development of a comprehensive mathematical model for the electrode wear rate (EWR) of a graphite tool in EDM on Ti-5Al-2.5Sn alloy, which has not yet been presented. Experiments for positive polarity of the graphite electrode, based on design of experiment (DOE), are first conducted. Modeling and analysis are carried out through the response surface methodology, utilizing the experimental results. A confirmation test is also executed to confirm the validity and the accuracy of the mathematical model developed. The confirmation test exhibits an average error of less than 6%. Negative electrode wear is evidenced for particular settings. The combination of 15A peak current, 350µs pulse-on time, 180µs pulse-off time and 95V servo-voltage and positive polarity causes negative tool wear. It is apparent that the developed model can evaluate electrode wear rate accurately and successfully. |
format |
Article |
author |
Khan, Md. Ashikur Rahman M. M., Rahman K., Kadirgama |
author_facet |
Khan, Md. Ashikur Rahman M. M., Rahman K., Kadirgama |
author_sort |
Khan, Md. Ashikur Rahman |
title |
Electrode Wear Rate of Graphite Electrodes during Electrical Discharge Machining Processes on Titanium Alloy Ti-5Al-2.5Sn |
title_short |
Electrode Wear Rate of Graphite Electrodes during Electrical Discharge Machining Processes on Titanium Alloy Ti-5Al-2.5Sn |
title_full |
Electrode Wear Rate of Graphite Electrodes during Electrical Discharge Machining Processes on Titanium Alloy Ti-5Al-2.5Sn |
title_fullStr |
Electrode Wear Rate of Graphite Electrodes during Electrical Discharge Machining Processes on Titanium Alloy Ti-5Al-2.5Sn |
title_full_unstemmed |
Electrode Wear Rate of Graphite Electrodes during Electrical Discharge Machining Processes on Titanium Alloy Ti-5Al-2.5Sn |
title_sort |
electrode wear rate of graphite electrodes during electrical discharge machining processes on titanium alloy ti-5al-2.5sn |
publisher |
Universiti Malaysia Pahang |
publishDate |
2014 |
url |
http://umpir.ump.edu.my/id/eprint/8174/1/26_Khan_et_al.pdf http://umpir.ump.edu.my/id/eprint/8174/ http://dx.doi.org/10.15282/ijame.9.2013.26.0148 |
_version_ |
1643665802109386752 |