Conductometric immunosensor for specific Escherichia coli O157:H7 detection on chemically funcationalizaed interdigitated aptasensor
Escherichia coli O157:H7 is a strain of Escherichia coli known for causing foodborne illness through the consumption of contaminated or raw food. To detect this pathogen, a conductometric immunosensor was developed using a conductometric sensing approach. The sensor was constructed on an interdigita...
Saved in:
Main Authors: | , , , , , , , , , , |
---|---|
Format: | Article |
Language: | English English |
Published: |
Elsevier Ltd
2024
|
Subjects: | |
Online Access: | https://eprints.ums.edu.my/id/eprint/41608/1/ABSTRACT.pdf https://eprints.ums.edu.my/id/eprint/41608/2/FULL%20TEXT.pdf https://eprints.ums.edu.my/id/eprint/41608/ https://doi.org/10.1016/j.heliyon.2024.e26988 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaysia Sabah |
Language: | English English |
id |
my.ums.eprints.41608 |
---|---|
record_format |
eprints |
spelling |
my.ums.eprints.416082024-10-25T01:24:57Z https://eprints.ums.edu.my/id/eprint/41608/ Conductometric immunosensor for specific Escherichia coli O157:H7 detection on chemically funcationalizaed interdigitated aptasensor Muhammad Nur Afnan Uda Alaa Kamal Yousif Dafhalla Thikra S. Dhahi Tijjani Adam Subash Chandra Bose Gopinath Asral Bahari ambek Muhammad Nur Aiman Uda Mohammed Mohammed Nor Azizah Parmin Nur Hulwani Ibrahim Uda Hashim QD71-142 Analytical chemistry QR1-502 Microbiology Escherichia coli O157:H7 is a strain of Escherichia coli known for causing foodborne illness through the consumption of contaminated or raw food. To detect this pathogen, a conductometric immunosensor was developed using a conductometric sensing approach. The sensor was constructed on an interdigitated electrode and modified with a monoclonal anti-Escherichia coli O157: H7 aptamer. A total of 200 electrode pairs were fabricated and modified to bind to the target molecule replica. The binding replica, acting as the bio-recognizer, was linked to the electrode surface using 3-Aminopropyl triethoxysilane. The sensor exhibited excellent performance, detecting Escherichia coli O157:H7 in a short time frame and demonstrating a wide detection range of 1 fM to 1 nM. Concentrations of Escherichia coli O157:H7 were detected within this range, with a minimum detection limit of 1 fM. This innovative sensor offers simplicity, speed, high sensitivity, selectivity, and the potential for rapid sample processing. The potential of this proposed biosensor is particularly beneficial in applications such as drug screening, environmental monitoring, and disease diagnosis, where real-time information on biomolecular interactions is crucial for timely decision-making and where cross-reactivity or interference may compromise the accuracy of the analysis. Elsevier Ltd 2024 Article NonPeerReviewed text en https://eprints.ums.edu.my/id/eprint/41608/1/ABSTRACT.pdf text en https://eprints.ums.edu.my/id/eprint/41608/2/FULL%20TEXT.pdf Muhammad Nur Afnan Uda and Alaa Kamal Yousif Dafhalla and Thikra S. Dhahi and Tijjani Adam and Subash Chandra Bose Gopinath and Asral Bahari ambek and Muhammad Nur Aiman Uda and Mohammed Mohammed and Nor Azizah Parmin and Nur Hulwani Ibrahim and Uda Hashim (2024) Conductometric immunosensor for specific Escherichia coli O157:H7 detection on chemically funcationalizaed interdigitated aptasensor. Heliyon, 10. pp. 1-9. ISSN 2405-8440 https://doi.org/10.1016/j.heliyon.2024.e26988 |
institution |
Universiti Malaysia Sabah |
building |
UMS Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Sabah |
content_source |
UMS Institutional Repository |
url_provider |
http://eprints.ums.edu.my/ |
language |
English English |
topic |
QD71-142 Analytical chemistry QR1-502 Microbiology |
spellingShingle |
QD71-142 Analytical chemistry QR1-502 Microbiology Muhammad Nur Afnan Uda Alaa Kamal Yousif Dafhalla Thikra S. Dhahi Tijjani Adam Subash Chandra Bose Gopinath Asral Bahari ambek Muhammad Nur Aiman Uda Mohammed Mohammed Nor Azizah Parmin Nur Hulwani Ibrahim Uda Hashim Conductometric immunosensor for specific Escherichia coli O157:H7 detection on chemically funcationalizaed interdigitated aptasensor |
description |
Escherichia coli O157:H7 is a strain of Escherichia coli known for causing foodborne illness through the consumption of contaminated or raw food. To detect this pathogen, a conductometric immunosensor was developed using a conductometric sensing approach. The sensor was constructed on an interdigitated electrode and modified with a monoclonal anti-Escherichia coli O157: H7 aptamer. A total of 200 electrode pairs were fabricated and modified to bind to the target molecule replica. The binding replica, acting as the bio-recognizer, was linked to the electrode surface using 3-Aminopropyl triethoxysilane. The sensor exhibited excellent performance, detecting Escherichia coli O157:H7 in a short time frame and demonstrating a wide detection range of 1 fM to 1 nM. Concentrations of Escherichia coli O157:H7 were detected within this range, with a minimum detection limit of 1 fM. This innovative sensor offers simplicity, speed, high sensitivity, selectivity, and the potential for rapid sample processing. The potential of this proposed biosensor is particularly beneficial in applications such as drug screening, environmental monitoring, and disease diagnosis, where real-time information on biomolecular interactions is crucial for timely decision-making and where cross-reactivity or interference may compromise the accuracy of the analysis. |
format |
Article |
author |
Muhammad Nur Afnan Uda Alaa Kamal Yousif Dafhalla Thikra S. Dhahi Tijjani Adam Subash Chandra Bose Gopinath Asral Bahari ambek Muhammad Nur Aiman Uda Mohammed Mohammed Nor Azizah Parmin Nur Hulwani Ibrahim Uda Hashim |
author_facet |
Muhammad Nur Afnan Uda Alaa Kamal Yousif Dafhalla Thikra S. Dhahi Tijjani Adam Subash Chandra Bose Gopinath Asral Bahari ambek Muhammad Nur Aiman Uda Mohammed Mohammed Nor Azizah Parmin Nur Hulwani Ibrahim Uda Hashim |
author_sort |
Muhammad Nur Afnan Uda |
title |
Conductometric immunosensor for specific Escherichia coli O157:H7 detection on chemically funcationalizaed interdigitated aptasensor |
title_short |
Conductometric immunosensor for specific Escherichia coli O157:H7 detection on chemically funcationalizaed interdigitated aptasensor |
title_full |
Conductometric immunosensor for specific Escherichia coli O157:H7 detection on chemically funcationalizaed interdigitated aptasensor |
title_fullStr |
Conductometric immunosensor for specific Escherichia coli O157:H7 detection on chemically funcationalizaed interdigitated aptasensor |
title_full_unstemmed |
Conductometric immunosensor for specific Escherichia coli O157:H7 detection on chemically funcationalizaed interdigitated aptasensor |
title_sort |
conductometric immunosensor for specific escherichia coli o157:h7 detection on chemically funcationalizaed interdigitated aptasensor |
publisher |
Elsevier Ltd |
publishDate |
2024 |
url |
https://eprints.ums.edu.my/id/eprint/41608/1/ABSTRACT.pdf https://eprints.ums.edu.my/id/eprint/41608/2/FULL%20TEXT.pdf https://eprints.ums.edu.my/id/eprint/41608/ https://doi.org/10.1016/j.heliyon.2024.e26988 |
_version_ |
1814049479200866304 |