Investigating Ultra Violet (UV) Strength against Different Level of Altitude using New Environmental Data Management System

This paper presents the investigation results of UV measurement at different level of altitudes and the development of a new portable instrument for measuring UV. The rapid growth of industrial sectors in developing countries including Malaysia, brings not only income to the nation, but also causes...

Full description

Saved in:
Bibliographic Details
Main Authors: Abas, Amir M., M. Dahlui, UniKL BMI
Format:
Language:English
Published: 2013
Subjects:
Online Access:http://ir.unikl.edu.my/jspui/handle/123456789/5144
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Kuala Lumpur
Language: English
id my.unikl.ir-5144
record_format eprints
spelling my.unikl.ir-51442014-02-27T02:59:36Z Investigating Ultra Violet (UV) Strength against Different Level of Altitude using New Environmental Data Management System Abas, Amir M. M. Dahlui UniKL BMI Ozone Layer Monitoring Global Warming Measurement Ultraviolet This paper presents the investigation results of UV measurement at different level of altitudes and the development of a new portable instrument for measuring UV. The rapid growth of industrial sectors in developing countries including Malaysia, brings not only income to the nation, but also causes pollution in various forms. Air pollution is one of the significant contributors to global warming by depleting the Ozone layer, which would reduce the filtration of UV rays. Long duration of exposure to high to UV rays has many devastating health effects to mankind directly or indirectly through destruction of the natural resources. This study aimed to show correlation between UV and altitudes which indirectly can help predict Ozone depletion. An instrument had been designed to measure and monitors the level of UV. The instrument comprises of two main blocks namely data logger and Graphic User Interface (GUI). Three sensors were used in the data logger to detect changes in the temperature, humidity and ultraviolet. The system has undergone experimental measurement to capture data at two different conditions; industrial area and high attitude area. The performance of the instrument showed consistency in the data captured and the results of the experiment drew a significantly high reading of UV at high altitudes. 2013-12-05T03:23:45Z 2013-12-05T03:23:45Z 2013-12-05 http://ir.unikl.edu.my/jspui/handle/123456789/5144 en
institution Universiti Kuala Lumpur
building UniKL Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Kuala Lumpur
content_source UniKL Institutional Repository
url_provider http://ir.unikl.edu.my/
language English
topic Ozone Layer
Monitoring
Global Warming
Measurement
Ultraviolet
spellingShingle Ozone Layer
Monitoring
Global Warming
Measurement
Ultraviolet
Abas, Amir M.
M. Dahlui
UniKL BMI
Investigating Ultra Violet (UV) Strength against Different Level of Altitude using New Environmental Data Management System
description This paper presents the investigation results of UV measurement at different level of altitudes and the development of a new portable instrument for measuring UV. The rapid growth of industrial sectors in developing countries including Malaysia, brings not only income to the nation, but also causes pollution in various forms. Air pollution is one of the significant contributors to global warming by depleting the Ozone layer, which would reduce the filtration of UV rays. Long duration of exposure to high to UV rays has many devastating health effects to mankind directly or indirectly through destruction of the natural resources. This study aimed to show correlation between UV and altitudes which indirectly can help predict Ozone depletion. An instrument had been designed to measure and monitors the level of UV. The instrument comprises of two main blocks namely data logger and Graphic User Interface (GUI). Three sensors were used in the data logger to detect changes in the temperature, humidity and ultraviolet. The system has undergone experimental measurement to capture data at two different conditions; industrial area and high attitude area. The performance of the instrument showed consistency in the data captured and the results of the experiment drew a significantly high reading of UV at high altitudes.
format
author Abas, Amir M.
M. Dahlui
UniKL BMI
author_facet Abas, Amir M.
M. Dahlui
UniKL BMI
author_sort Abas, Amir M.
title Investigating Ultra Violet (UV) Strength against Different Level of Altitude using New Environmental Data Management System
title_short Investigating Ultra Violet (UV) Strength against Different Level of Altitude using New Environmental Data Management System
title_full Investigating Ultra Violet (UV) Strength against Different Level of Altitude using New Environmental Data Management System
title_fullStr Investigating Ultra Violet (UV) Strength against Different Level of Altitude using New Environmental Data Management System
title_full_unstemmed Investigating Ultra Violet (UV) Strength against Different Level of Altitude using New Environmental Data Management System
title_sort investigating ultra violet (uv) strength against different level of altitude using new environmental data management system
publishDate 2013
url http://ir.unikl.edu.my/jspui/handle/123456789/5144
_version_ 1644484688324067328