Comparison on losses and flux distribution among three 3-phase distribution transformers 1000kVA assembled from various amount of layers per stack of transformers core lamination

Organized by Universiti Kuala Lumpur (UniKL), 11th - 13th December 2007 at Kuala Lumpur, Malaysia.

Saved in:
Bibliographic Details
Main Authors: Ismail, Daut, Dina Maizana, Maiz Ahmad, Shuhaimi, Zakaria, Soib, Taib
Format: Working Paper
Language:English
Published: Universiti Kuala Lumpur (UniKL) 2008
Subjects:
Online Access:http://dspace.unimap.edu.my/xmlui/handle/123456789/2197
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaysia Perlis
Language: English
id my.unimap-2197
record_format dspace
spelling my.unimap-21972014-05-05T06:38:23Z Comparison on losses and flux distribution among three 3-phase distribution transformers 1000kVA assembled from various amount of layers per stack of transformers core lamination Ismail, Daut Dina Maizana, Maiz Ahmad Shuhaimi, Zakaria Soib, Taib Transformer core Flux distribution Harmonic flux Power loss Building Factor (BF) Transformers Electronics transformers Electric transformers Organized by Universiti Kuala Lumpur (UniKL), 11th - 13th December 2007 at Kuala Lumpur, Malaysia. This paper describes the results of an investigarion on the effect of different amount of layers per stack of core lamination in the three of 3 phase distribution transformers 1000kVA. The investigation involves the variant of power loss, building factor, total harmonic distortion of flux and flux leakages. The power loss and flux distribution have been measured using no load test in three types of model of setting of core built from the same size and type of M5 (CGO) laminations. The power loss of the transformer core assembled with 1 layer per stack of lamination is 7% better than the power loss of the transformer core assembled with 2 layer per stack of lamination and is also 9% better than the power loss of the transformer core assembled with 3 layers per stack of lamination, at 1.7T, 50 Hz. The flux leakage at the corner joint in the core assembled with 1 layer per stack of lamination is the lowest among the three of the transformer cores, over the whole flux density range. Total harmonic distortion flux is the largest in the transformer core with 3 layers per stack of lamination and smallest in the transformer core with 1 layer per stack lamination. Using 1 layer per stack of lamination of the transformer core. 2008-09-15T01:13:14Z 2008-09-15T01:13:14Z 2007-12-13 Working Paper http://hdl.handle.net/123456789/2197 en International Conference on Engineering Technology 2007 (ICET 2007) Universiti Kuala Lumpur (UniKL)
institution Universiti Malaysia Perlis
building UniMAP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Perlis
content_source UniMAP Library Digital Repository
url_provider http://dspace.unimap.edu.my/
language English
topic Transformer core
Flux distribution
Harmonic flux
Power loss
Building Factor (BF)
Transformers
Electronics transformers
Electric transformers
spellingShingle Transformer core
Flux distribution
Harmonic flux
Power loss
Building Factor (BF)
Transformers
Electronics transformers
Electric transformers
Ismail, Daut
Dina Maizana, Maiz Ahmad
Shuhaimi, Zakaria
Soib, Taib
Comparison on losses and flux distribution among three 3-phase distribution transformers 1000kVA assembled from various amount of layers per stack of transformers core lamination
description Organized by Universiti Kuala Lumpur (UniKL), 11th - 13th December 2007 at Kuala Lumpur, Malaysia.
format Working Paper
author Ismail, Daut
Dina Maizana, Maiz Ahmad
Shuhaimi, Zakaria
Soib, Taib
author_facet Ismail, Daut
Dina Maizana, Maiz Ahmad
Shuhaimi, Zakaria
Soib, Taib
author_sort Ismail, Daut
title Comparison on losses and flux distribution among three 3-phase distribution transformers 1000kVA assembled from various amount of layers per stack of transformers core lamination
title_short Comparison on losses and flux distribution among three 3-phase distribution transformers 1000kVA assembled from various amount of layers per stack of transformers core lamination
title_full Comparison on losses and flux distribution among three 3-phase distribution transformers 1000kVA assembled from various amount of layers per stack of transformers core lamination
title_fullStr Comparison on losses and flux distribution among three 3-phase distribution transformers 1000kVA assembled from various amount of layers per stack of transformers core lamination
title_full_unstemmed Comparison on losses and flux distribution among three 3-phase distribution transformers 1000kVA assembled from various amount of layers per stack of transformers core lamination
title_sort comparison on losses and flux distribution among three 3-phase distribution transformers 1000kva assembled from various amount of layers per stack of transformers core lamination
publisher Universiti Kuala Lumpur (UniKL)
publishDate 2008
url http://dspace.unimap.edu.my/xmlui/handle/123456789/2197