Comparison on losses and flux distribution among three 3-phase distribution transformers 1000kVA assembled from various amount of layers per stack of transformers core lamination
Organized by Universiti Kuala Lumpur (UniKL), 11th - 13th December 2007 at Kuala Lumpur, Malaysia.
Saved in:
Main Authors: | , , , |
---|---|
Format: | Working Paper |
Language: | English |
Published: |
Universiti Kuala Lumpur (UniKL)
2008
|
Subjects: | |
Online Access: | http://dspace.unimap.edu.my/xmlui/handle/123456789/2197 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaysia Perlis |
Language: | English |
id |
my.unimap-2197 |
---|---|
record_format |
dspace |
spelling |
my.unimap-21972014-05-05T06:38:23Z Comparison on losses and flux distribution among three 3-phase distribution transformers 1000kVA assembled from various amount of layers per stack of transformers core lamination Ismail, Daut Dina Maizana, Maiz Ahmad Shuhaimi, Zakaria Soib, Taib Transformer core Flux distribution Harmonic flux Power loss Building Factor (BF) Transformers Electronics transformers Electric transformers Organized by Universiti Kuala Lumpur (UniKL), 11th - 13th December 2007 at Kuala Lumpur, Malaysia. This paper describes the results of an investigarion on the effect of different amount of layers per stack of core lamination in the three of 3 phase distribution transformers 1000kVA. The investigation involves the variant of power loss, building factor, total harmonic distortion of flux and flux leakages. The power loss and flux distribution have been measured using no load test in three types of model of setting of core built from the same size and type of M5 (CGO) laminations. The power loss of the transformer core assembled with 1 layer per stack of lamination is 7% better than the power loss of the transformer core assembled with 2 layer per stack of lamination and is also 9% better than the power loss of the transformer core assembled with 3 layers per stack of lamination, at 1.7T, 50 Hz. The flux leakage at the corner joint in the core assembled with 1 layer per stack of lamination is the lowest among the three of the transformer cores, over the whole flux density range. Total harmonic distortion flux is the largest in the transformer core with 3 layers per stack of lamination and smallest in the transformer core with 1 layer per stack lamination. Using 1 layer per stack of lamination of the transformer core. 2008-09-15T01:13:14Z 2008-09-15T01:13:14Z 2007-12-13 Working Paper http://hdl.handle.net/123456789/2197 en International Conference on Engineering Technology 2007 (ICET 2007) Universiti Kuala Lumpur (UniKL) |
institution |
Universiti Malaysia Perlis |
building |
UniMAP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Perlis |
content_source |
UniMAP Library Digital Repository |
url_provider |
http://dspace.unimap.edu.my/ |
language |
English |
topic |
Transformer core Flux distribution Harmonic flux Power loss Building Factor (BF) Transformers Electronics transformers Electric transformers |
spellingShingle |
Transformer core Flux distribution Harmonic flux Power loss Building Factor (BF) Transformers Electronics transformers Electric transformers Ismail, Daut Dina Maizana, Maiz Ahmad Shuhaimi, Zakaria Soib, Taib Comparison on losses and flux distribution among three 3-phase distribution transformers 1000kVA assembled from various amount of layers per stack of transformers core lamination |
description |
Organized by Universiti Kuala Lumpur (UniKL), 11th - 13th December 2007 at Kuala Lumpur, Malaysia. |
format |
Working Paper |
author |
Ismail, Daut Dina Maizana, Maiz Ahmad Shuhaimi, Zakaria Soib, Taib |
author_facet |
Ismail, Daut Dina Maizana, Maiz Ahmad Shuhaimi, Zakaria Soib, Taib |
author_sort |
Ismail, Daut |
title |
Comparison on losses and flux distribution among three 3-phase distribution transformers 1000kVA assembled from various amount of layers per stack of transformers core lamination |
title_short |
Comparison on losses and flux distribution among three 3-phase distribution transformers 1000kVA assembled from various amount of layers per stack of transformers core lamination |
title_full |
Comparison on losses and flux distribution among three 3-phase distribution transformers 1000kVA assembled from various amount of layers per stack of transformers core lamination |
title_fullStr |
Comparison on losses and flux distribution among three 3-phase distribution transformers 1000kVA assembled from various amount of layers per stack of transformers core lamination |
title_full_unstemmed |
Comparison on losses and flux distribution among three 3-phase distribution transformers 1000kVA assembled from various amount of layers per stack of transformers core lamination |
title_sort |
comparison on losses and flux distribution among three 3-phase distribution transformers 1000kva assembled from various amount of layers per stack of transformers core lamination |
publisher |
Universiti Kuala Lumpur (UniKL) |
publishDate |
2008 |
url |
http://dspace.unimap.edu.my/xmlui/handle/123456789/2197 |
_version_ |
1643787525182980096 |