Structural performance of grouted sleeve connectors with and without transverse reinforcement for precast concrete structure
Malaysian Technical Universities Conference on Engineering and Technology (MUCET) 2012 organised by technical universities under the Malaysian Technical Universities Network (MTUN), 20th - 21st November 2012 at Hotel Seri Malaysia, Kangar, Perlis.
Saved in:
Main Authors: | , , , |
---|---|
Other Authors: | |
Format: | Working Paper |
Language: | English |
Published: |
Malaysian Technical Universities Network (MTUN)
2013
|
Subjects: | |
Online Access: | http://dspace.unimap.edu.my/xmlui/handle/123456789/29895 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaysia Perlis |
Language: | English |
id |
my.unimap-29895 |
---|---|
record_format |
dspace |
spelling |
my.unimap-298952013-11-20T07:10:00Z Structural performance of grouted sleeve connectors with and without transverse reinforcement for precast concrete structure Aizat, Alias Mohammad Amirulkhairi, Zubir Khairul Anuar, Shahid Ahmad Baharuddin, Abd Rahman aizat@ump.edu.my amirulkhairi@ump.edu.my khairulanuars@ump.edu.my baharfka@utm.my Component Confinement action End-to-end Transverse reinforcement Grouted sleeve connector Malaysian Technical Universities Conference on Engineering and Technology (MUCET) 2012 organised by technical universities under the Malaysian Technical Universities Network (MTUN), 20th - 21st November 2012 at Hotel Seri Malaysia, Kangar, Perlis. This paper presents the performance of the proposed grouted sleeve connector with and without steel spiral as transverse reinforcement under incremental tensile load until failure. The connector utilized mild steel pipe as sleeve where the sleeve consists of external and internal sleeve with the diameter of the external sleeve is larger than internal sleeve. The mild steel pipe and the steel spiral are used to confine and reinforce the grout and the two discontinued bars spliced end-to-end configuration in the sleeve. The test shows that, there are two modes of failure which were bar slipped and bar fractured outside the sleeve. Eleven specimens out of fourteen shows satisfactory results as it failed due to bar fractured outside the sleeve and achieve satisfactory ultimate tensile capacity. The stiffness and the ductility of the connectors also satisfy. Grouted sleeve connectors with steel spiral perform better compared to connectors without a steel spiral. The test shows that the performance of the grouted sleeve connector with or without steel spiral was governed by grout-bar bond, anchorage length and confinement action provided by the sleeve and the steel spiral. The connectors have a potential to be used in connecting precast concrete structure. 2013-11-20T07:10:00Z 2013-11-20T07:10:00Z 2012-11-20 Working Paper p. 455-460 http://hdl.handle.net/123456789/29895 en Proceeding of the Malaysian Technical Universities Conference on Engineering and Technology (MUCET) 2012; Malaysian Technical Universities Network (MTUN) |
institution |
Universiti Malaysia Perlis |
building |
UniMAP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Perlis |
content_source |
UniMAP Library Digital Repository |
url_provider |
http://dspace.unimap.edu.my/ |
language |
English |
topic |
Component Confinement action End-to-end Transverse reinforcement Grouted sleeve connector |
spellingShingle |
Component Confinement action End-to-end Transverse reinforcement Grouted sleeve connector Aizat, Alias Mohammad Amirulkhairi, Zubir Khairul Anuar, Shahid Ahmad Baharuddin, Abd Rahman Structural performance of grouted sleeve connectors with and without transverse reinforcement for precast concrete structure |
description |
Malaysian Technical Universities Conference on Engineering and Technology (MUCET) 2012 organised by technical universities under the Malaysian Technical Universities Network (MTUN), 20th - 21st November 2012 at Hotel Seri Malaysia, Kangar, Perlis. |
author2 |
aizat@ump.edu.my |
author_facet |
aizat@ump.edu.my Aizat, Alias Mohammad Amirulkhairi, Zubir Khairul Anuar, Shahid Ahmad Baharuddin, Abd Rahman |
format |
Working Paper |
author |
Aizat, Alias Mohammad Amirulkhairi, Zubir Khairul Anuar, Shahid Ahmad Baharuddin, Abd Rahman |
author_sort |
Aizat, Alias |
title |
Structural performance of grouted sleeve connectors with and without transverse reinforcement for precast concrete structure |
title_short |
Structural performance of grouted sleeve connectors with and without transverse reinforcement for precast concrete structure |
title_full |
Structural performance of grouted sleeve connectors with and without transverse reinforcement for precast concrete structure |
title_fullStr |
Structural performance of grouted sleeve connectors with and without transverse reinforcement for precast concrete structure |
title_full_unstemmed |
Structural performance of grouted sleeve connectors with and without transverse reinforcement for precast concrete structure |
title_sort |
structural performance of grouted sleeve connectors with and without transverse reinforcement for precast concrete structure |
publisher |
Malaysian Technical Universities Network (MTUN) |
publishDate |
2013 |
url |
http://dspace.unimap.edu.my/xmlui/handle/123456789/29895 |
_version_ |
1643795534601781248 |