Fire resistance of biomass ash panels used for internal partitions in buildings

Malaysian Technical Universities Conference on Engineering and Technology (MUCET) 2012 organised by technical universities under the Malaysian Technical Universities Network (MTUN), 20th - 21st November 2012 at Hotel Seri Malaysia, Kangar, Perlis.

Saved in:
Bibliographic Details
Main Authors: Roshazita, Che Amat, Norlia, Mohamad Ibrahim, Nur Liza, Rahim, Nur Saidatul Balqish, Ahmad Tajudin, Khairel Rafezi, Ahmad, Dr.
Other Authors: roshazita@unimap.edu.my
Format: Working Paper
Language:English
Published: Malaysian Technical Universities Network (MTUN) 2013
Subjects:
Online Access:http://dspace.unimap.edu.my/xmlui/handle/123456789/29898
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaysia Perlis
Language: English
id my.unimap-29898
record_format dspace
spelling my.unimap-298982013-11-20T08:37:14Z Fire resistance of biomass ash panels used for internal partitions in buildings Roshazita, Che Amat Norlia, Mohamad Ibrahim Nur Liza, Rahim Nur Saidatul Balqish, Ahmad Tajudin Khairel Rafezi, Ahmad, Dr. roshazita@unimap.edu.my norlia@unimap.edu.my nurliza@unimap.edu.my rafezi@unimap.edu.my Empty Fruit Bunch (EFB) Panel Biomass ash Gypsum board Fire resistance Malaysian Technical Universities Conference on Engineering and Technology (MUCET) 2012 organised by technical universities under the Malaysian Technical Universities Network (MTUN), 20th - 21st November 2012 at Hotel Seri Malaysia, Kangar, Perlis. constructions. This study develop new products made of by biomass ash from industry waste for the internal partitions panel. Modifying the internal partition panel of wall with addition of biomass ash (EFB) and clay soils in producing new products that can resist and retain durability and resilience of the panel products to the fire. ASTM C1396 Standard Specification for Gypsum Board defines Gypsum wallboard as designed wallboard use for on walls, ceilings, or partitions and that affords a surface suitable to receive decoration tested in accordance with ASTM E1 19 Standard Test Methods for Fire Tests of Building Construction and Materials. For this study, fire resistance, thermal and mechanical parameters were measured. The panels which are 100 mm × 100 mm by 15 mm thick were prepared following ASTM standard. The product here studied in the form of low-density panels (800 kg/m) has a great potential for an industrial use, showing similar properties to those found in commercial gypsum plasterboard, a material of generalized use for this type of application. Consequently, from the test, biomass ash (EFB) panel board can retain more than 2 hours fire resistance in standard conditions of room temperature by fire laboratory and panels showing a compressive strength of 3.535 MPa. 2013-11-20T08:37:14Z 2013-11-20T08:37:14Z 2012-11-20 Working Paper p. 405-409 http://hdl.handle.net/123456789/29898 en Proceeding of the Malaysian Technical Universities Conference on Engineering and Technology (MUCET) 2012; Malaysian Technical Universities Network (MTUN)
institution Universiti Malaysia Perlis
building UniMAP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Perlis
content_source UniMAP Library Digital Repository
url_provider http://dspace.unimap.edu.my/
language English
topic Empty Fruit Bunch (EFB)
Panel
Biomass ash
Gypsum board
Fire resistance
spellingShingle Empty Fruit Bunch (EFB)
Panel
Biomass ash
Gypsum board
Fire resistance
Roshazita, Che Amat
Norlia, Mohamad Ibrahim
Nur Liza, Rahim
Nur Saidatul Balqish, Ahmad Tajudin
Khairel Rafezi, Ahmad, Dr.
Fire resistance of biomass ash panels used for internal partitions in buildings
description Malaysian Technical Universities Conference on Engineering and Technology (MUCET) 2012 organised by technical universities under the Malaysian Technical Universities Network (MTUN), 20th - 21st November 2012 at Hotel Seri Malaysia, Kangar, Perlis.
author2 roshazita@unimap.edu.my
author_facet roshazita@unimap.edu.my
Roshazita, Che Amat
Norlia, Mohamad Ibrahim
Nur Liza, Rahim
Nur Saidatul Balqish, Ahmad Tajudin
Khairel Rafezi, Ahmad, Dr.
format Working Paper
author Roshazita, Che Amat
Norlia, Mohamad Ibrahim
Nur Liza, Rahim
Nur Saidatul Balqish, Ahmad Tajudin
Khairel Rafezi, Ahmad, Dr.
author_sort Roshazita, Che Amat
title Fire resistance of biomass ash panels used for internal partitions in buildings
title_short Fire resistance of biomass ash panels used for internal partitions in buildings
title_full Fire resistance of biomass ash panels used for internal partitions in buildings
title_fullStr Fire resistance of biomass ash panels used for internal partitions in buildings
title_full_unstemmed Fire resistance of biomass ash panels used for internal partitions in buildings
title_sort fire resistance of biomass ash panels used for internal partitions in buildings
publisher Malaysian Technical Universities Network (MTUN)
publishDate 2013
url http://dspace.unimap.edu.my/xmlui/handle/123456789/29898
_version_ 1643795501083000832