Microstructure and in-vitro test bioactivity behavior of Co-Cr-Mo (F-75)/hydroxyapatite in phosphate buffered saline solution

Link to publisher's homepage at http://www.qip-journal.eu

Saved in:
Bibliographic Details
Main Authors: Shamsul Baharin, Jamaludin, Prof. Dr., Nur Maizatul Shima, Adzali, Mohd Nazree, Derman, Dr.
Other Authors: sbaharin@unimap.edu.my
Format: Article
Language:English
Published: Technical University of Košice 2014
Subjects:
Online Access:http://dspace.unimap.edu.my:80/dspace/handle/123456789/32848
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaysia Perlis
Language: English
id my.unimap-32848
record_format dspace
spelling my.unimap-328482014-03-19T03:24:13Z Microstructure and in-vitro test bioactivity behavior of Co-Cr-Mo (F-75)/hydroxyapatite in phosphate buffered saline solution Shamsul Baharin, Jamaludin, Prof. Dr. Nur Maizatul Shima, Adzali Mohd Nazree, Derman, Dr. sbaharin@unimap.edu.my Powder metallurgy In-vitro Biomaterials Link to publisher's homepage at http://www.qip-journal.eu Cobalt based alloys were the first metallic materials successfully used in orthopedic applications. However, these alloys are bioinert, it is necessary to make them bioactive in the human body to improve their application as biomaterials. This research reported the microstructure and in-vitro bioactivity behavior of the novel Co-Cr-Mo alloy (ASTM F-75) filled with different amounts of hydroxyapatites (HAP). F-75 powder was mixed with 2, 6 and 10 wt. % of HAP before being cold compacted at 550 MPa using a uniaxial press machine. The composites then were sintered at 1100°C for 2 h. In-vitro bioactivity behavior of the composites was evaluated by immersing the composites into simulated body fluids for up to 18 days. Results showed that the nucleus of apatite, identified as the apatite layer formed on the surface of the prepared F-75/HAP composite after 18 days of immersion in the phosphate buffered solution (PBS). The Co-Cr-Mo alloy was successfully converted into a bioactive composite by adding 2, 6 and 10 wt. % of HAP particles. It was proposed that the formation of the apatite layer on the surface of F-75/HAP can contribute to the improved biocompatibility and osteoconductivity of F-75/HAP 2014-03-19T03:24:13Z 2014-03-19T03:24:13Z 2014 Article Acta Metallurgica Slovaca, vol.20 (1), 2014, pages 82-88 1335-1532 (print) 1338-1156 (online) http://dspace.unimap.edu.my:80/dspace/handle/123456789/32848 http://www.qip-journal.eu/index.php/ams/article/view/192/225 en Technical University of Košice
institution Universiti Malaysia Perlis
building UniMAP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Perlis
content_source UniMAP Library Digital Repository
url_provider http://dspace.unimap.edu.my/
language English
topic Powder metallurgy
In-vitro
Biomaterials
spellingShingle Powder metallurgy
In-vitro
Biomaterials
Shamsul Baharin, Jamaludin, Prof. Dr.
Nur Maizatul Shima, Adzali
Mohd Nazree, Derman, Dr.
Microstructure and in-vitro test bioactivity behavior of Co-Cr-Mo (F-75)/hydroxyapatite in phosphate buffered saline solution
description Link to publisher's homepage at http://www.qip-journal.eu
author2 sbaharin@unimap.edu.my
author_facet sbaharin@unimap.edu.my
Shamsul Baharin, Jamaludin, Prof. Dr.
Nur Maizatul Shima, Adzali
Mohd Nazree, Derman, Dr.
format Article
author Shamsul Baharin, Jamaludin, Prof. Dr.
Nur Maizatul Shima, Adzali
Mohd Nazree, Derman, Dr.
author_sort Shamsul Baharin, Jamaludin, Prof. Dr.
title Microstructure and in-vitro test bioactivity behavior of Co-Cr-Mo (F-75)/hydroxyapatite in phosphate buffered saline solution
title_short Microstructure and in-vitro test bioactivity behavior of Co-Cr-Mo (F-75)/hydroxyapatite in phosphate buffered saline solution
title_full Microstructure and in-vitro test bioactivity behavior of Co-Cr-Mo (F-75)/hydroxyapatite in phosphate buffered saline solution
title_fullStr Microstructure and in-vitro test bioactivity behavior of Co-Cr-Mo (F-75)/hydroxyapatite in phosphate buffered saline solution
title_full_unstemmed Microstructure and in-vitro test bioactivity behavior of Co-Cr-Mo (F-75)/hydroxyapatite in phosphate buffered saline solution
title_sort microstructure and in-vitro test bioactivity behavior of co-cr-mo (f-75)/hydroxyapatite in phosphate buffered saline solution
publisher Technical University of Košice
publishDate 2014
url http://dspace.unimap.edu.my:80/dspace/handle/123456789/32848
_version_ 1643797006297071616