Development and testing of new anode efficiency system for sacrificial anode

Magnesium based alloy is the most suitable material as sacrificial anodes for corrosion control in underground environment. Performance of control corrosion by anode was depend on efficiency to protect cathode from corrode. Develop of the new system for determines efficiency of anode. The systems...

Full description

Saved in:
Bibliographic Details
Main Author: Mohd Redzwan Rosli
Other Authors: Shaiful Rizam Shamsudin (Advisor)
Format: Learning Object
Language:English
Published: Universiti Malaysia Perlis 2008
Subjects:
Online Access:http://dspace.unimap.edu.my/xmlui/handle/123456789/3355
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaysia Perlis
Language: English
id my.unimap-3355
record_format dspace
spelling my.unimap-33552008-11-27T01:47:59Z Development and testing of new anode efficiency system for sacrificial anode Mohd Redzwan Rosli Shaiful Rizam Shamsudin (Advisor) Corrosion protection Anodes Soil corrosion Corrosion and anti-corrosives Corrosions -- Prevention Cathodic protection Magnesium based alloy is the most suitable material as sacrificial anodes for corrosion control in underground environment. Performance of control corrosion by anode was depend on efficiency to protect cathode from corrode. Develop of the new system for determines efficiency of anode. The systems are combination between of impressed current and sacrificial concept. Single and triple corrosion cell its 2 new system, where the both it different design. Single corrosion cell was use a container, thus this system must be test repeated at least 3 range values at 1 type of specimen. The efficiency and actual current capacity value of PMg using single corrosion cell is 48.48% and 1069.83 Ah/kg respectively. For triple corrosion cell it use 3 containers, thus advantage this system is the reduce time consuming testing because requires only a tested for a type of specimen. The efficiency and actual current capacity value of HPMg using triple corrosion cell is 55.11% and 1215.928Ah/kg respectively. Methods system, current flow, electrolyte resistivity and specimen preparation are the influencing for evaluate the efficiency of anode. The value of efficiency will be changing when the effect exist in efficiency testing of anode. Circuit open potential was the additional system to evaluate of anode performance. This system to measure potential value exists in connection between anode specimen and saturated calomel reference electrode. The potential of electronegative value for HPMg higher than PMg was -1740mV. The other hand pitting dept for HPMg lower than PMg was 127um. It cause expects life of HPMg was long. 2008-11-27T01:47:59Z 2008-11-27T01:47:59Z 2008-04 Learning Object http://hdl.handle.net/123456789/3355 en Universiti Malaysia Perlis School of Materials Engineering
institution Universiti Malaysia Perlis
building UniMAP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Perlis
content_source UniMAP Library Digital Repository
url_provider http://dspace.unimap.edu.my/
language English
topic Corrosion protection
Anodes
Soil corrosion
Corrosion and anti-corrosives
Corrosions -- Prevention
Cathodic protection
spellingShingle Corrosion protection
Anodes
Soil corrosion
Corrosion and anti-corrosives
Corrosions -- Prevention
Cathodic protection
Mohd Redzwan Rosli
Development and testing of new anode efficiency system for sacrificial anode
description Magnesium based alloy is the most suitable material as sacrificial anodes for corrosion control in underground environment. Performance of control corrosion by anode was depend on efficiency to protect cathode from corrode. Develop of the new system for determines efficiency of anode. The systems are combination between of impressed current and sacrificial concept. Single and triple corrosion cell its 2 new system, where the both it different design. Single corrosion cell was use a container, thus this system must be test repeated at least 3 range values at 1 type of specimen. The efficiency and actual current capacity value of PMg using single corrosion cell is 48.48% and 1069.83 Ah/kg respectively. For triple corrosion cell it use 3 containers, thus advantage this system is the reduce time consuming testing because requires only a tested for a type of specimen. The efficiency and actual current capacity value of HPMg using triple corrosion cell is 55.11% and 1215.928Ah/kg respectively. Methods system, current flow, electrolyte resistivity and specimen preparation are the influencing for evaluate the efficiency of anode. The value of efficiency will be changing when the effect exist in efficiency testing of anode. Circuit open potential was the additional system to evaluate of anode performance. This system to measure potential value exists in connection between anode specimen and saturated calomel reference electrode. The potential of electronegative value for HPMg higher than PMg was -1740mV. The other hand pitting dept for HPMg lower than PMg was 127um. It cause expects life of HPMg was long.
author2 Shaiful Rizam Shamsudin (Advisor)
author_facet Shaiful Rizam Shamsudin (Advisor)
Mohd Redzwan Rosli
format Learning Object
author Mohd Redzwan Rosli
author_sort Mohd Redzwan Rosli
title Development and testing of new anode efficiency system for sacrificial anode
title_short Development and testing of new anode efficiency system for sacrificial anode
title_full Development and testing of new anode efficiency system for sacrificial anode
title_fullStr Development and testing of new anode efficiency system for sacrificial anode
title_full_unstemmed Development and testing of new anode efficiency system for sacrificial anode
title_sort development and testing of new anode efficiency system for sacrificial anode
publisher Universiti Malaysia Perlis
publishDate 2008
url http://dspace.unimap.edu.my/xmlui/handle/123456789/3355
_version_ 1643787789359120384