A study on contraction of Pneumatic Artificial Muscle (PAM) for load-lifting
Access is limited to UniMAP community.
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Learning Object |
Language: | English |
Published: |
Universiti Malaysia Perlis (UniMAP)
2021
|
Subjects: | |
Online Access: | http://dspace.unimap.edu.my:80/xmlui/handle/123456789/69877 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaysia Perlis |
Language: | English |
id |
my.unimap-69877 |
---|---|
record_format |
dspace |
spelling |
my.unimap-698772021-02-25T03:00:04Z A study on contraction of Pneumatic Artificial Muscle (PAM) for load-lifting Amanina Nadia, Soaid Mohammad Taufiq, Mustaffa, Dr. Pneumatic Artificial Muscle (PAM) Load-lifting Muscle Human body Access is limited to UniMAP community. Pneumatic Artificial Muscle (PAM) is a type of actuator that similar to human muscle. The PAM is used for converting pneumatic power to pulling force and eventually causing movements of the mechanism. One of the potential usages of the PAM is load-lifting applications. In order to enhance the application of PAM, it is necessary to understand the basis of PAM development. But, only few numbers of study discuss the parameters and suitability of braided mesh with bladder that could enhance the PAM performance. To solve this problem, this study more focused on investigating the compatibility of braided mesh with bladder and also the relationship of length and diameter bladder. The high performance of PAM can be calculated from the higher value of contraction. The braided mesh suitability experiment and the effect of force load on PAM contraction experiment has been carried out to find the optimum size of PAM that lead to the maximum contraction. The experimental results show the relationship of bladder parameter with the braided mesh is necessary to increase the performance of PAM. The case studies is to verify the contraction value under various load when same diameter and different length is used for the PAM. 2021-02-25T03:00:04Z 2021-02-25T03:00:04Z 2016-06 Learning Object http://dspace.unimap.edu.my:80/xmlui/handle/123456789/69877 en Universiti Malaysia Perlis (UniMAP) |
institution |
Universiti Malaysia Perlis |
building |
UniMAP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Perlis |
content_source |
UniMAP Library Digital Repository |
url_provider |
http://dspace.unimap.edu.my/ |
language |
English |
topic |
Pneumatic Artificial Muscle (PAM) Load-lifting Muscle Human body |
spellingShingle |
Pneumatic Artificial Muscle (PAM) Load-lifting Muscle Human body Amanina Nadia, Soaid A study on contraction of Pneumatic Artificial Muscle (PAM) for load-lifting |
description |
Access is limited to UniMAP community. |
author2 |
Mohammad Taufiq, Mustaffa, Dr. |
author_facet |
Mohammad Taufiq, Mustaffa, Dr. Amanina Nadia, Soaid |
format |
Learning Object |
author |
Amanina Nadia, Soaid |
author_sort |
Amanina Nadia, Soaid |
title |
A study on contraction of Pneumatic Artificial Muscle (PAM) for load-lifting |
title_short |
A study on contraction of Pneumatic Artificial Muscle (PAM) for load-lifting |
title_full |
A study on contraction of Pneumatic Artificial Muscle (PAM) for load-lifting |
title_fullStr |
A study on contraction of Pneumatic Artificial Muscle (PAM) for load-lifting |
title_full_unstemmed |
A study on contraction of Pneumatic Artificial Muscle (PAM) for load-lifting |
title_sort |
study on contraction of pneumatic artificial muscle (pam) for load-lifting |
publisher |
Universiti Malaysia Perlis (UniMAP) |
publishDate |
2021 |
url |
http://dspace.unimap.edu.my:80/xmlui/handle/123456789/69877 |
_version_ |
1698698272354336768 |