Partial discharge detection and location technique based on segmented correlation trimmed mean algorithm for power cable
Doctor of Philosophy in Electrical Systems Engineering
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Thesis |
Language: | English |
Published: |
Universiti Malaysia Perlis (UniMAP)
2017
|
Subjects: | |
Online Access: | http://dspace.unimap.edu.my:80/xmlui/handle/123456789/78039 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaysia Perlis |
Language: | English |
id |
my.unimap-78039 |
---|---|
record_format |
dspace |
spelling |
my.unimap-780392023-03-07T02:23:11Z Partial discharge detection and location technique based on segmented correlation trimmed mean algorithm for power cable Chai, Chang Yii Muzamir, Isa, Assoc. Prof. Dr. Electric discharges Current transformers (Instrument transformer) Electric instrument transformers Chemical detectors Power cable Partial discharge (PD) Doctor of Philosophy in Electrical Systems Engineering Power cable may suffer from insulation degradation after a certain period of time because of environment, mechanical and electrical factors. Partial discharge (PD) at void or cavity of power cable’s insulation will lead to the power system breakdown in the near future. Nowadays, many PD location devices had been invented to estimate PD location on power cable. New technology has enabled PD estimation to evolve from offline PD estimation to online PD estimation. Advanced signal processing technique can be implemented in those devices in order to estimate PD location accurately. In this thesis, segmented correlation trimmed mean (SCTM) algorithm is proposed to estimate PD location on medium voltage (MV) power cable. The algorithm uses segmented correlation technique and trimmed mean data filtering technique to enhance the accuracy of the estimated PD location. Two experiments have been performed to test the program execution time and accuracy against noise of the algorithm. The algorithm had been tested in Matrix Laboratory (MATLAB) environment which consists modelled PD signals and different levels of white Gaussian noise (WGN) and discrete spectral interference (DSI). Discrete wavelet transform (DWT) de-nosing technique has been used for noise suppression. The first experiment is performed by increasing the sampling number of measured signal while recording the program execution time of the algorithm. The second experiment is performed by increasing the level of WGN and DSI while recording the maximum percentage error of the estimated PD location. The results from both experiments are compared with the existing multi-end correlation (MEC) algorithm. The results shown that the SCTM algorithm has longer time but lower maximum percentage error of the estimated PD location than MEC algorithm. In conclusion, SCTM algorithm is more suitable to apply in PD location estimation system for power cable due to its lower maximum percentage error. 2017 2023-03-07T02:23:11Z 2023-03-07T02:23:11Z Thesis http://dspace.unimap.edu.my:80/xmlui/handle/123456789/78039 en Universiti Malaysia Perlis (UniMAP) Universiti Malaysia Perlis (UniMAP) School of Electrical Systems Engineering |
institution |
Universiti Malaysia Perlis |
building |
UniMAP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Perlis |
content_source |
UniMAP Library Digital Repository |
url_provider |
http://dspace.unimap.edu.my/ |
language |
English |
topic |
Electric discharges Current transformers (Instrument transformer) Electric instrument transformers Chemical detectors Power cable Partial discharge (PD) |
spellingShingle |
Electric discharges Current transformers (Instrument transformer) Electric instrument transformers Chemical detectors Power cable Partial discharge (PD) Chai, Chang Yii Partial discharge detection and location technique based on segmented correlation trimmed mean algorithm for power cable |
description |
Doctor of Philosophy in Electrical Systems Engineering |
author2 |
Muzamir, Isa, Assoc. Prof. Dr. |
author_facet |
Muzamir, Isa, Assoc. Prof. Dr. Chai, Chang Yii |
format |
Thesis |
author |
Chai, Chang Yii |
author_sort |
Chai, Chang Yii |
title |
Partial discharge detection and location technique based on segmented correlation trimmed mean algorithm for power cable |
title_short |
Partial discharge detection and location technique based on segmented correlation trimmed mean algorithm for power cable |
title_full |
Partial discharge detection and location technique based on segmented correlation trimmed mean algorithm for power cable |
title_fullStr |
Partial discharge detection and location technique based on segmented correlation trimmed mean algorithm for power cable |
title_full_unstemmed |
Partial discharge detection and location technique based on segmented correlation trimmed mean algorithm for power cable |
title_sort |
partial discharge detection and location technique based on segmented correlation trimmed mean algorithm for power cable |
publisher |
Universiti Malaysia Perlis (UniMAP) |
publishDate |
2017 |
url |
http://dspace.unimap.edu.my:80/xmlui/handle/123456789/78039 |
_version_ |
1772813092496867328 |