Carbon nanoparticle modified screen printed carbon electrode as a disposable electrochemical immunosensor strip for the detection of Japanese encephalitis virus

The authors describe a disposable electrochemical immunosensor strip for the detection of the Japanese encephalitis virus (JEV). The assay is based on the use of a screen printed carbon electrode (SPCE) modified with carbon nanoparticles (CNPs) that were prepared from starch nanoparticles and d...

Full description

Saved in:
Bibliographic Details
Main Authors: Suk, Fun Chin, Lih, Shan Lim, Suh, Cem Pang, Magdline Sia, Henry Sum, David, Perera
Format: E-Article
Language:English
Published: Springer-Verlag 2017
Subjects:
Online Access:http://ir.unimas.my/id/eprint/15276/7/Carbon%20nanoparticle%20modified%20screen%20printed%20carbon%20electrode%20%28abstract%29.pdf
http://ir.unimas.my/id/eprint/15276/
https://link.springer.com/article/10.1007/s00604-016-2029-7
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaysia Sarawak
Language: English
id my.unimas.ir.15276
record_format eprints
spelling my.unimas.ir.152762017-08-29T07:24:20Z http://ir.unimas.my/id/eprint/15276/ Carbon nanoparticle modified screen printed carbon electrode as a disposable electrochemical immunosensor strip for the detection of Japanese encephalitis virus Suk, Fun Chin Lih, Shan Lim Suh, Cem Pang Magdline Sia, Henry Sum David, Perera Q Science (General) QR180 Immunology QR355 Virology R Medicine (General) The authors describe a disposable electrochemical immunosensor strip for the detection of the Japanese encephalitis virus (JEV). The assay is based on the use of a screen printed carbon electrode (SPCE) modified with carbon nanoparticles (CNPs) that were prepared from starch nanoparticles and deposited on the SPCE working electrode whose surface was functionalized with 3-aminopropyl triethoxysilane. Next, antibody of JEV was immobilized on the surfaces of the CNPs. The analytical performance of immunosensor strip was characterized using cyclic voltammetry (with hexacyanoferrate as the redox probe) and electrochemical impedance spectroscopy. The deposition of CNPs enhances the electron transfer kinetics and current intensity of the SPCE by 63% compared to an unmodified SPCE. Under optimized conditions, the calibration plot is linear within the 5–20 ng·mL−1 JEV concentration range, the limit of detection being 2 ng·mL−1 (at an S/N ratio of 3), and the assay time is 20 min. This immunosensor strip was successfully applied to the detection of JEV in human serum samples. It represents a cost-effective alternative to conventional diagnostic tests for JEV. Springer-Verlag 2017 E-Article PeerReviewed text en http://ir.unimas.my/id/eprint/15276/7/Carbon%20nanoparticle%20modified%20screen%20printed%20carbon%20electrode%20%28abstract%29.pdf Suk, Fun Chin and Lih, Shan Lim and Suh, Cem Pang and Magdline Sia, Henry Sum and David, Perera (2017) Carbon nanoparticle modified screen printed carbon electrode as a disposable electrochemical immunosensor strip for the detection of Japanese encephalitis virus. Microchimica Acta, 184 (2). pp. 491-497. ISSN 1436-5073 https://link.springer.com/article/10.1007/s00604-016-2029-7 DOI 10.1007/s00604-016-2029-7
institution Universiti Malaysia Sarawak
building Centre for Academic Information Services (CAIS)
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Sarawak
content_source UNIMAS Institutional Repository
url_provider http://ir.unimas.my/
language English
topic Q Science (General)
QR180 Immunology
QR355 Virology
R Medicine (General)
spellingShingle Q Science (General)
QR180 Immunology
QR355 Virology
R Medicine (General)
Suk, Fun Chin
Lih, Shan Lim
Suh, Cem Pang
Magdline Sia, Henry Sum
David, Perera
Carbon nanoparticle modified screen printed carbon electrode as a disposable electrochemical immunosensor strip for the detection of Japanese encephalitis virus
description The authors describe a disposable electrochemical immunosensor strip for the detection of the Japanese encephalitis virus (JEV). The assay is based on the use of a screen printed carbon electrode (SPCE) modified with carbon nanoparticles (CNPs) that were prepared from starch nanoparticles and deposited on the SPCE working electrode whose surface was functionalized with 3-aminopropyl triethoxysilane. Next, antibody of JEV was immobilized on the surfaces of the CNPs. The analytical performance of immunosensor strip was characterized using cyclic voltammetry (with hexacyanoferrate as the redox probe) and electrochemical impedance spectroscopy. The deposition of CNPs enhances the electron transfer kinetics and current intensity of the SPCE by 63% compared to an unmodified SPCE. Under optimized conditions, the calibration plot is linear within the 5–20 ng·mL−1 JEV concentration range, the limit of detection being 2 ng·mL−1 (at an S/N ratio of 3), and the assay time is 20 min. This immunosensor strip was successfully applied to the detection of JEV in human serum samples. It represents a cost-effective alternative to conventional diagnostic tests for JEV.
format E-Article
author Suk, Fun Chin
Lih, Shan Lim
Suh, Cem Pang
Magdline Sia, Henry Sum
David, Perera
author_facet Suk, Fun Chin
Lih, Shan Lim
Suh, Cem Pang
Magdline Sia, Henry Sum
David, Perera
author_sort Suk, Fun Chin
title Carbon nanoparticle modified screen printed carbon electrode as a disposable electrochemical immunosensor strip for the detection of Japanese encephalitis virus
title_short Carbon nanoparticle modified screen printed carbon electrode as a disposable electrochemical immunosensor strip for the detection of Japanese encephalitis virus
title_full Carbon nanoparticle modified screen printed carbon electrode as a disposable electrochemical immunosensor strip for the detection of Japanese encephalitis virus
title_fullStr Carbon nanoparticle modified screen printed carbon electrode as a disposable electrochemical immunosensor strip for the detection of Japanese encephalitis virus
title_full_unstemmed Carbon nanoparticle modified screen printed carbon electrode as a disposable electrochemical immunosensor strip for the detection of Japanese encephalitis virus
title_sort carbon nanoparticle modified screen printed carbon electrode as a disposable electrochemical immunosensor strip for the detection of japanese encephalitis virus
publisher Springer-Verlag
publishDate 2017
url http://ir.unimas.my/id/eprint/15276/7/Carbon%20nanoparticle%20modified%20screen%20printed%20carbon%20electrode%20%28abstract%29.pdf
http://ir.unimas.my/id/eprint/15276/
https://link.springer.com/article/10.1007/s00604-016-2029-7
_version_ 1644512112158965760