Development of a system to improve safety in switching of high voltage circuit breaker

The aim of this project is to create a safety system that develops a Pneumatic system to break High voltage switchgear (11KV to 33kV). This project has the grant scheme by OSAKA Gas Foundation in Cultural Exchanged Research (OGFIGE). It focuses on designing and constructing a switchgear breaker sys...

Full description

Saved in:
Bibliographic Details
Main Author: Muhammad Atif, Bin Norzan Shah.
Format: Final Year Project Report
Language:English
English
Published: Universiti Malaysia Sarawak (UNIMAS) 2017
Subjects:
Online Access:http://ir.unimas.my/id/eprint/26306/1/Development%20of%20a%20system%20to%20improve%20safety%2024pgs.pdf
http://ir.unimas.my/id/eprint/26306/4/Development%20of%20a%20system%20to%20improve%20safety%20ft.pdf
http://ir.unimas.my/id/eprint/26306/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaysia Sarawak
Language: English
English
id my.unimas.ir.26306
record_format eprints
spelling my.unimas.ir.263062023-08-17T08:13:30Z http://ir.unimas.my/id/eprint/26306/ Development of a system to improve safety in switching of high voltage circuit breaker Muhammad Atif, Bin Norzan Shah. TK Electrical engineering. Electronics Nuclear engineering The aim of this project is to create a safety system that develops a Pneumatic system to break High voltage switchgear (11KV to 33kV). This project has the grant scheme by OSAKA Gas Foundation in Cultural Exchanged Research (OGFIGE). It focuses on designing and constructing a switchgear breaker system that can do the switching process in substations without using any manpower and most of all, switching is done remotely by indisputable distances. By allowing service personnel to stand outside the arc-flash boundary at substations while assigned to do the switching, the remote switch operators reduce the need for a full-body arc flash hazard suit. The architecture and design of the remote switch system consist of 2.5 Horsepower Air Compressor, Electrical contacts, Contactor with ON and OFF contact, Circuit Breaker, Electro-pneumatic valve, Electro-pneumatic cylinder, Connecting wires, Ratchet Strap, and Pneumatic tubing and others. An optimum design of the remote switch is determined by its ability to break the actual Sarawak Energy selected Switchgears. Therefore, the size of the pneumatic cylinder is taken into consideration whether it is the optimum size to be installed onto the switchgear. Universiti Malaysia Sarawak (UNIMAS) 2017 Final Year Project Report NonPeerReviewed text en http://ir.unimas.my/id/eprint/26306/1/Development%20of%20a%20system%20to%20improve%20safety%2024pgs.pdf text en http://ir.unimas.my/id/eprint/26306/4/Development%20of%20a%20system%20to%20improve%20safety%20ft.pdf Muhammad Atif, Bin Norzan Shah. (2017) Development of a system to improve safety in switching of high voltage circuit breaker. [Final Year Project Report] (Unpublished)
institution Universiti Malaysia Sarawak
building Centre for Academic Information Services (CAIS)
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Sarawak
content_source UNIMAS Institutional Repository
url_provider http://ir.unimas.my/
language English
English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Muhammad Atif, Bin Norzan Shah.
Development of a system to improve safety in switching of high voltage circuit breaker
description The aim of this project is to create a safety system that develops a Pneumatic system to break High voltage switchgear (11KV to 33kV). This project has the grant scheme by OSAKA Gas Foundation in Cultural Exchanged Research (OGFIGE). It focuses on designing and constructing a switchgear breaker system that can do the switching process in substations without using any manpower and most of all, switching is done remotely by indisputable distances. By allowing service personnel to stand outside the arc-flash boundary at substations while assigned to do the switching, the remote switch operators reduce the need for a full-body arc flash hazard suit. The architecture and design of the remote switch system consist of 2.5 Horsepower Air Compressor, Electrical contacts, Contactor with ON and OFF contact, Circuit Breaker, Electro-pneumatic valve, Electro-pneumatic cylinder, Connecting wires, Ratchet Strap, and Pneumatic tubing and others. An optimum design of the remote switch is determined by its ability to break the actual Sarawak Energy selected Switchgears. Therefore, the size of the pneumatic cylinder is taken into consideration whether it is the optimum size to be installed onto the switchgear.
format Final Year Project Report
author Muhammad Atif, Bin Norzan Shah.
author_facet Muhammad Atif, Bin Norzan Shah.
author_sort Muhammad Atif, Bin Norzan Shah.
title Development of a system to improve safety in switching of high voltage circuit breaker
title_short Development of a system to improve safety in switching of high voltage circuit breaker
title_full Development of a system to improve safety in switching of high voltage circuit breaker
title_fullStr Development of a system to improve safety in switching of high voltage circuit breaker
title_full_unstemmed Development of a system to improve safety in switching of high voltage circuit breaker
title_sort development of a system to improve safety in switching of high voltage circuit breaker
publisher Universiti Malaysia Sarawak (UNIMAS)
publishDate 2017
url http://ir.unimas.my/id/eprint/26306/1/Development%20of%20a%20system%20to%20improve%20safety%2024pgs.pdf
http://ir.unimas.my/id/eprint/26306/4/Development%20of%20a%20system%20to%20improve%20safety%20ft.pdf
http://ir.unimas.my/id/eprint/26306/
_version_ 1775627254133424128