SIMULATION OF DEFECTS ON MEDIUM VOLTAFE CROSSLINKED POLYETHYLENE (XLPE) CABLE INSULATION USING FINITE ELEMENT ANALYSIS

Cross-Linked Polyethylene (XLPE) is one of the types in polymer that is used as the insulator in power cable. This type of insulation is widely used in the medium voltage due to it necessarily being installed. In addition, this insulation is economically attractive as it is less expensive compare to...

Full description

Saved in:
Bibliographic Details
Main Author: KELVIN JUING, TINGGOM
Format: Final Year Project Report
Language:English
English
Published: Universiti Malaysia Sarawak, (UNIMAS) 2019
Subjects:
Online Access:http://ir.unimas.my/id/eprint/34476/1/SIMULATION%20OF%20DEFECTS%20ON%20MEDIUM%20VOLTAFE24pgs.pdf
http://ir.unimas.my/id/eprint/34476/6/Kelvin%20Juing.pdf
http://ir.unimas.my/id/eprint/34476/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaysia Sarawak
Language: English
English
id my.unimas.ir.34476
record_format eprints
spelling my.unimas.ir.344762024-01-10T07:35:59Z http://ir.unimas.my/id/eprint/34476/ SIMULATION OF DEFECTS ON MEDIUM VOLTAFE CROSSLINKED POLYETHYLENE (XLPE) CABLE INSULATION USING FINITE ELEMENT ANALYSIS KELVIN JUING, TINGGOM TK Electrical engineering. Electronics Nuclear engineering Cross-Linked Polyethylene (XLPE) is one of the types in polymer that is used as the insulator in power cable. This type of insulation is widely used in the medium voltage due to it necessarily being installed. In addition, this insulation is economically attractive as it is less expensive compare to the most advance and strong material type in insulation material choices. The problem in this XLPE cable is the degradation which caused by the partial discharges that have been initiated at the specific location where the abnormalities had occurred toward the XLPE material. Partial discharge is small electrical discharges caused by massive electrical stress modification due to the fault circumstances. In this work, electric field distribution and its strength is observed by finite element analysis. The defect that will be observed is air void, vented water tree and bow-tie water tree. Each defect sizes will be manipulated, and the location of the defect being located are changes where it will place on the insulator which is closer to the conductor, middle of the insulator and far from conductor. Next, the rated voltage will be varying to compare the electric field distribution. The design and modelling of the cable in this work will be conforming to IEC 60502-2 Standard. As result, the electric field intensity will be increased when there is the defect occur on the insulator. The vented water tree defect gives the highest value of electric field intensity followed by the bow-tie water tree and air void defect. In air void defect, the electric field intensity will increase when the size of defect is increased. This is due to the different relative permittivity that have been injected in the defect during simulation which resulting to the non-uniform electric field line distribution on the insulator and electric field stress occur. Universiti Malaysia Sarawak, (UNIMAS) 2019 Final Year Project Report NonPeerReviewed text en http://ir.unimas.my/id/eprint/34476/1/SIMULATION%20OF%20DEFECTS%20ON%20MEDIUM%20VOLTAFE24pgs.pdf text en http://ir.unimas.my/id/eprint/34476/6/Kelvin%20Juing.pdf KELVIN JUING, TINGGOM (2019) SIMULATION OF DEFECTS ON MEDIUM VOLTAFE CROSSLINKED POLYETHYLENE (XLPE) CABLE INSULATION USING FINITE ELEMENT ANALYSIS. [Final Year Project Report] (Unpublished)
institution Universiti Malaysia Sarawak
building Centre for Academic Information Services (CAIS)
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Sarawak
content_source UNIMAS Institutional Repository
url_provider http://ir.unimas.my/
language English
English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
KELVIN JUING, TINGGOM
SIMULATION OF DEFECTS ON MEDIUM VOLTAFE CROSSLINKED POLYETHYLENE (XLPE) CABLE INSULATION USING FINITE ELEMENT ANALYSIS
description Cross-Linked Polyethylene (XLPE) is one of the types in polymer that is used as the insulator in power cable. This type of insulation is widely used in the medium voltage due to it necessarily being installed. In addition, this insulation is economically attractive as it is less expensive compare to the most advance and strong material type in insulation material choices. The problem in this XLPE cable is the degradation which caused by the partial discharges that have been initiated at the specific location where the abnormalities had occurred toward the XLPE material. Partial discharge is small electrical discharges caused by massive electrical stress modification due to the fault circumstances. In this work, electric field distribution and its strength is observed by finite element analysis. The defect that will be observed is air void, vented water tree and bow-tie water tree. Each defect sizes will be manipulated, and the location of the defect being located are changes where it will place on the insulator which is closer to the conductor, middle of the insulator and far from conductor. Next, the rated voltage will be varying to compare the electric field distribution. The design and modelling of the cable in this work will be conforming to IEC 60502-2 Standard. As result, the electric field intensity will be increased when there is the defect occur on the insulator. The vented water tree defect gives the highest value of electric field intensity followed by the bow-tie water tree and air void defect. In air void defect, the electric field intensity will increase when the size of defect is increased. This is due to the different relative permittivity that have been injected in the defect during simulation which resulting to the non-uniform electric field line distribution on the insulator and electric field stress occur.
format Final Year Project Report
author KELVIN JUING, TINGGOM
author_facet KELVIN JUING, TINGGOM
author_sort KELVIN JUING, TINGGOM
title SIMULATION OF DEFECTS ON MEDIUM VOLTAFE CROSSLINKED POLYETHYLENE (XLPE) CABLE INSULATION USING FINITE ELEMENT ANALYSIS
title_short SIMULATION OF DEFECTS ON MEDIUM VOLTAFE CROSSLINKED POLYETHYLENE (XLPE) CABLE INSULATION USING FINITE ELEMENT ANALYSIS
title_full SIMULATION OF DEFECTS ON MEDIUM VOLTAFE CROSSLINKED POLYETHYLENE (XLPE) CABLE INSULATION USING FINITE ELEMENT ANALYSIS
title_fullStr SIMULATION OF DEFECTS ON MEDIUM VOLTAFE CROSSLINKED POLYETHYLENE (XLPE) CABLE INSULATION USING FINITE ELEMENT ANALYSIS
title_full_unstemmed SIMULATION OF DEFECTS ON MEDIUM VOLTAFE CROSSLINKED POLYETHYLENE (XLPE) CABLE INSULATION USING FINITE ELEMENT ANALYSIS
title_sort simulation of defects on medium voltafe crosslinked polyethylene (xlpe) cable insulation using finite element analysis
publisher Universiti Malaysia Sarawak, (UNIMAS)
publishDate 2019
url http://ir.unimas.my/id/eprint/34476/1/SIMULATION%20OF%20DEFECTS%20ON%20MEDIUM%20VOLTAFE24pgs.pdf
http://ir.unimas.my/id/eprint/34476/6/Kelvin%20Juing.pdf
http://ir.unimas.my/id/eprint/34476/
_version_ 1789430328253743104