Calibrated Analytical Model of Low Cost YL-69 Hygrometer Sensor for Determining Moisture Content of Fruit and Vegetable Waste
Moisture content (MC) is one of the influential parameters in food waste composting process. With the use of low aeration rate in achieving minimal loss of moisture, 60% moisture content is found to be the optimum indicator. There is a need to retain moisture of the composting process at this set po...