Earthing system is very important in order to protect the electrical equipment as well as the human’s safety against over voltages. The main function of the earthling system is to remove unwanted excessive electrical currents caused by unusual conditions such as fault and lightning or switching over...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Published: |
2020
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Tenaga Nasional |
Language: | English |
id |
my.uniten.dspace-12780 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-127802020-08-19T06:03:51Z Evaluation of transient response of different earthing configurations due to lightning impulses Wai, L.M. Abd Rahman, M.S. Mohd Ariffin, A. Nik Ali, N.H. Osman, M. Ab Kadir, M.Z.A. Earthing system is very important in order to protect the electrical equipment as well as the human’s safety against over voltages. The main function of the earthling system is to remove unwanted excessive electrical currents caused by unusual conditions such as fault and lightning or switching over voltages by providing a low resistance path to the earth. Researchers had studied the behaviour of the earthling system to improve its performance for the past few years. There are few factors that influence the performance of the earthling system such as soil resistivity and soil ionization which need to be focused in order to improve the earthling. Thus, this paper evaluates on the factors that affect the behaviour of the earthling system based on simulation works using MATLAB and Safe Grid Software. Some analytical calculations are used to obtain the soil resistivity and resistance as well as the touch and step voltages. The simulation results were validated based on comparison with other studies on the factors that influence the earthling system performance. The results reveal that the variation of soil resistivity, the configuration of electrodes, current magnitude and frequency dependence can result in a change of transient response of the systems. © BEIESP. 2020-02-03T03:26:44Z 2020-02-03T03:26:44Z 2019-07 Conference Proceeding 10.35940/ijrte.D5118.118419 en 5th International Conference on Energy and Environment 2019 (Icee), |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
language |
English |
description |
Earthing system is very important in order to protect the electrical equipment as well as the human’s safety against over voltages. The main function of the earthling system is to remove unwanted excessive electrical currents caused by unusual conditions such as fault and lightning or switching over voltages by providing a low resistance path to the earth. Researchers had studied the behaviour of the earthling system to improve its performance for the past few years. There are few factors that influence the performance of the earthling system such as soil resistivity and soil ionization which need to be focused in order to improve the earthling. Thus, this paper evaluates on the factors that affect the behaviour of the earthling system based on simulation works using MATLAB and Safe Grid Software. Some analytical calculations are used to obtain the soil resistivity and resistance as well as the touch and step voltages. The simulation results were validated based on comparison with other studies on the factors that influence the earthling system performance. The results reveal that the variation of soil resistivity, the configuration of electrodes, current magnitude and frequency dependence can result in a change of transient response of the systems. © BEIESP. |
format |
Conference Proceeding |
author |
Wai, L.M. Abd Rahman, M.S. Mohd Ariffin, A. Nik Ali, N.H. Osman, M. Ab Kadir, M.Z.A. |
spellingShingle |
Wai, L.M. Abd Rahman, M.S. Mohd Ariffin, A. Nik Ali, N.H. Osman, M. Ab Kadir, M.Z.A. Evaluation of transient response of different earthing configurations due to lightning impulses |
author_facet |
Wai, L.M. Abd Rahman, M.S. Mohd Ariffin, A. Nik Ali, N.H. Osman, M. Ab Kadir, M.Z.A. |
author_sort |
Wai, L.M. |
title |
Evaluation of transient response of different earthing configurations due to lightning impulses |
title_short |
Evaluation of transient response of different earthing configurations due to lightning impulses |
title_full |
Evaluation of transient response of different earthing configurations due to lightning impulses |
title_fullStr |
Evaluation of transient response of different earthing configurations due to lightning impulses |
title_full_unstemmed |
Evaluation of transient response of different earthing configurations due to lightning impulses |
title_sort |
evaluation of transient response of different earthing configurations due to lightning impulses |
publishDate |
2020 |
_version_ |
1678595884856639488 |