Determination of favorable blood glucose target range for stochastic TARgeted (STAR) glycemic control in Malaysia
Stress-induced hyperglycemia is common in critically ill patients, but there is uncertainty about what constitutes an optimal blood glucose target range for glycemic control. Furthermore, to reduce the rate of hyperglycemic and hypoglycemic events, model-based glycemic control protocols have been in...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
2020
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Tenaga Nasional |
Language: | English |
id |
my.uniten.dspace-12971 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-129712020-07-07T03:15:47Z Determination of favorable blood glucose target range for stochastic TARgeted (STAR) glycemic control in Malaysia Abu-Samah, A. Razak, N.N.A. Jamaludin, U.K. Suhaimi, F.M. Ralib, A.M. Stress-induced hyperglycemia is common in critically ill patients, but there is uncertainty about what constitutes an optimal blood glucose target range for glycemic control. Furthermore, to reduce the rate of hyperglycemic and hypoglycemic events, model-based glycemic control protocols have been introduced, such as the stochastic targeted (STAR) glycemic control protocol. This protocol has been used in the intensive care units of Christchurch and Gyulà Hospital since 2010, and in Malaysia since 2017. In this study, we analyzed the adaptability of the protocol and identified the blood glucose target range most favorable for use in the Malaysian population. Virtual simulation results are presented for two clinical cohorts: one receiving treatment by the STAR protocol itself and the other receiving intensive insulin therapy by the sliding scale method. Performance and safety were analyzed using five clinical target ranges, and best control was simulated at a target range of 6.0–10.0 mmol/L. This target range had the best balance of performance, with the lowest risk of hypoglycemia and the lowest requirement for nursing interventions. The result is encouraging as the STAR protocol is suitable to provide better and safer glycemic control while using a target range that is already widely used in Malaysian intensive care units. © 2019 Institute of Advanced Engineering and Science. All rights reserved. 2020-02-03T03:28:12Z 2020-02-03T03:28:12Z 2019 Article 10.11591/ijeecs.v15.i1.pp133-141 en |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
language |
English |
description |
Stress-induced hyperglycemia is common in critically ill patients, but there is uncertainty about what constitutes an optimal blood glucose target range for glycemic control. Furthermore, to reduce the rate of hyperglycemic and hypoglycemic events, model-based glycemic control protocols have been introduced, such as the stochastic targeted (STAR) glycemic control protocol. This protocol has been used in the intensive care units of Christchurch and Gyulà Hospital since 2010, and in Malaysia since 2017. In this study, we analyzed the adaptability of the protocol and identified the blood glucose target range most favorable for use in the Malaysian population. Virtual simulation results are presented for two clinical cohorts: one receiving treatment by the STAR protocol itself and the other receiving intensive insulin therapy by the sliding scale method. Performance and safety were analyzed using five clinical target ranges, and best control was simulated at a target range of 6.0–10.0 mmol/L. This target range had the best balance of performance, with the lowest risk of hypoglycemia and the lowest requirement for nursing interventions. The result is encouraging as the STAR protocol is suitable to provide better and safer glycemic control while using a target range that is already widely used in Malaysian intensive care units. © 2019 Institute of Advanced Engineering and Science. All rights reserved. |
format |
Article |
author |
Abu-Samah, A. Razak, N.N.A. Jamaludin, U.K. Suhaimi, F.M. Ralib, A.M. |
spellingShingle |
Abu-Samah, A. Razak, N.N.A. Jamaludin, U.K. Suhaimi, F.M. Ralib, A.M. Determination of favorable blood glucose target range for stochastic TARgeted (STAR) glycemic control in Malaysia |
author_facet |
Abu-Samah, A. Razak, N.N.A. Jamaludin, U.K. Suhaimi, F.M. Ralib, A.M. |
author_sort |
Abu-Samah, A. |
title |
Determination of favorable blood glucose target range for stochastic TARgeted (STAR) glycemic control in Malaysia |
title_short |
Determination of favorable blood glucose target range for stochastic TARgeted (STAR) glycemic control in Malaysia |
title_full |
Determination of favorable blood glucose target range for stochastic TARgeted (STAR) glycemic control in Malaysia |
title_fullStr |
Determination of favorable blood glucose target range for stochastic TARgeted (STAR) glycemic control in Malaysia |
title_full_unstemmed |
Determination of favorable blood glucose target range for stochastic TARgeted (STAR) glycemic control in Malaysia |
title_sort |
determination of favorable blood glucose target range for stochastic targeted (star) glycemic control in malaysia |
publishDate |
2020 |
_version_ |
1672614194496667648 |