Combined analysis of electrical resistivity and geotechnical SPT blow counts for safety assessment
Electrical resistivity survey and the geotechnical SPT blow counts (N value) method were simultaneously analyze to investigate the stability of the earth sub-surface. The coupling of these heterogeneous field methods provided a chance to understand the status of underground materials by comparing th...
Saved in:
Main Author: | |
---|---|
Format: | text::Thesis |
Language: | English |
Published: |
2023
|
Subjects: | |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Tenaga Nasional |
Language: | English |
id |
my.uniten.dspace-21444 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-214442023-05-04T23:48:12Z Combined analysis of electrical resistivity and geotechnical SPT blow counts for safety assessment Mazni Yantty Binti Mohamad Jani Electric resistance Electrical resistivity survey and the geotechnical SPT blow counts (N value) method were simultaneously analyze to investigate the stability of the earth sub-surface. The coupling of these heterogeneous field methods provided a chance to understand the status of underground materials by comparing the geophysical and geotechnical view. The analysis shows that the zones with low resistivity value generally have low N value, which means low stiffness. However, some zones with a high resistivity pattern are not accompanied by an increase of its N value, and are even showing a lower N value. 2023-05-03T16:54:51Z 2023-05-03T16:54:51Z 2012 Resource Types::text::Thesis https://irepository.uniten.edu.my/handle/123456789/21444 en application/pdf |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
language |
English |
topic |
Electric resistance |
spellingShingle |
Electric resistance Mazni Yantty Binti Mohamad Jani Combined analysis of electrical resistivity and geotechnical SPT blow counts for safety assessment |
description |
Electrical resistivity survey and the geotechnical SPT blow counts (N value) method were simultaneously analyze to investigate the stability of the earth sub-surface. The coupling of these heterogeneous field methods provided a chance to understand the status of underground materials by comparing the geophysical and geotechnical view. The analysis shows that the zones with low resistivity value generally have low N value, which means low stiffness. However, some zones with a high resistivity pattern are not accompanied by an increase of its N value, and are even showing a lower N value. |
format |
Resource Types::text::Thesis |
author |
Mazni Yantty Binti Mohamad Jani |
author_facet |
Mazni Yantty Binti Mohamad Jani |
author_sort |
Mazni Yantty Binti Mohamad Jani |
title |
Combined analysis of electrical resistivity and geotechnical SPT blow counts for safety assessment |
title_short |
Combined analysis of electrical resistivity and geotechnical SPT blow counts for safety assessment |
title_full |
Combined analysis of electrical resistivity and geotechnical SPT blow counts for safety assessment |
title_fullStr |
Combined analysis of electrical resistivity and geotechnical SPT blow counts for safety assessment |
title_full_unstemmed |
Combined analysis of electrical resistivity and geotechnical SPT blow counts for safety assessment |
title_sort |
combined analysis of electrical resistivity and geotechnical spt blow counts for safety assessment |
publishDate |
2023 |
_version_ |
1806426534735511552 |