An Experimental Study on the Debonding of Steel and CFRP Strips Externally Bonded to Concrete in the Presence of Embedded Shear Connectors

The problem of debonding failure is a fundamental issue in concrete structures that are externally strengthened with adhesively glued plates. Many standards and studies recommend using single-lap pull-out tests to measure the ultimate force that causes debonding failure. The pull-out test also allow...

Full description

Saved in:
Bibliographic Details
Main Authors: Alam M.A., Alshaikhly A.S., Mustapha K.N.
Other Authors: 57199298044
Format: Article
Published: Springer Verlag 2023
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Tenaga Nasional
id my.uniten.dspace-22646
record_format dspace
spelling my.uniten.dspace-226462023-05-29T14:11:28Z An Experimental Study on the Debonding of Steel and CFRP Strips Externally Bonded to Concrete in the Presence of Embedded Shear Connectors Alam M.A. Alshaikhly A.S. Mustapha K.N. 57199298044 57190879266 26032672000 The problem of debonding failure is a fundamental issue in concrete structures that are externally strengthened with adhesively glued plates. Many standards and studies recommend using single-lap pull-out tests to measure the ultimate force that causes debonding failure. The pull-out test also allows defining and calibrating interface bond-slip relationships between concrete and the bonded plates to obtain the maximum interfacial bond strength. The aim of this research was to enhance bond strength in the presence of embedded shear connectors, which were fabricated at concrete�adhesive interface level to delay debonding of the externally bonded strips from the concrete surface. A new rational model was also proposed to predict the bond strength of adhesively glued plates-to-concrete joints in the presence of connectors. In the experimental programme, 60 concrete prisms with adhesive and steel bar connectors were fabricated. The specimens were divided into two main series of concrete prisms bonded with steel plates and CFRP strips using the new connectors. Different diameters of connectors were used with and without adhesive on the surfaces of concrete prisms to bond the strips for investigating the capacity of the new embedded connectors. The experimental results showed that the interfacial bond strength increased remarkably when these connectors were used. Moreover, it was found that increasing the connector�s diameter has a great effect on increasing the bond strength and uniformly distributes the interfacial shear stresses, leading to the minimisation of premature debonding failure of bonded plates. The results exhibited that the steel connectors are more effective at increasing the shear bond strength for all specimens adhesively glued with both CFRP strips and steel plates. Finally, the proposed bond strength model was satisfactorily verified through the experimental investigations. � 2016, King Fahd University of Petroleum & Minerals. Final 2023-05-29T06:11:28Z 2023-05-29T06:11:28Z 2016 Article 10.1007/s13369-016-2123-5 2-s2.0-84983802087 https://www.scopus.com/inward/record.uri?eid=2-s2.0-84983802087&doi=10.1007%2fs13369-016-2123-5&partnerID=40&md5=e9aa4873c7d97f1dc0163a0515885700 https://irepository.uniten.edu.my/handle/123456789/22646 41 10 4171 4186 Springer Verlag Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description The problem of debonding failure is a fundamental issue in concrete structures that are externally strengthened with adhesively glued plates. Many standards and studies recommend using single-lap pull-out tests to measure the ultimate force that causes debonding failure. The pull-out test also allows defining and calibrating interface bond-slip relationships between concrete and the bonded plates to obtain the maximum interfacial bond strength. The aim of this research was to enhance bond strength in the presence of embedded shear connectors, which were fabricated at concrete�adhesive interface level to delay debonding of the externally bonded strips from the concrete surface. A new rational model was also proposed to predict the bond strength of adhesively glued plates-to-concrete joints in the presence of connectors. In the experimental programme, 60 concrete prisms with adhesive and steel bar connectors were fabricated. The specimens were divided into two main series of concrete prisms bonded with steel plates and CFRP strips using the new connectors. Different diameters of connectors were used with and without adhesive on the surfaces of concrete prisms to bond the strips for investigating the capacity of the new embedded connectors. The experimental results showed that the interfacial bond strength increased remarkably when these connectors were used. Moreover, it was found that increasing the connector�s diameter has a great effect on increasing the bond strength and uniformly distributes the interfacial shear stresses, leading to the minimisation of premature debonding failure of bonded plates. The results exhibited that the steel connectors are more effective at increasing the shear bond strength for all specimens adhesively glued with both CFRP strips and steel plates. Finally, the proposed bond strength model was satisfactorily verified through the experimental investigations. � 2016, King Fahd University of Petroleum & Minerals.
author2 57199298044
author_facet 57199298044
Alam M.A.
Alshaikhly A.S.
Mustapha K.N.
format Article
author Alam M.A.
Alshaikhly A.S.
Mustapha K.N.
spellingShingle Alam M.A.
Alshaikhly A.S.
Mustapha K.N.
An Experimental Study on the Debonding of Steel and CFRP Strips Externally Bonded to Concrete in the Presence of Embedded Shear Connectors
author_sort Alam M.A.
title An Experimental Study on the Debonding of Steel and CFRP Strips Externally Bonded to Concrete in the Presence of Embedded Shear Connectors
title_short An Experimental Study on the Debonding of Steel and CFRP Strips Externally Bonded to Concrete in the Presence of Embedded Shear Connectors
title_full An Experimental Study on the Debonding of Steel and CFRP Strips Externally Bonded to Concrete in the Presence of Embedded Shear Connectors
title_fullStr An Experimental Study on the Debonding of Steel and CFRP Strips Externally Bonded to Concrete in the Presence of Embedded Shear Connectors
title_full_unstemmed An Experimental Study on the Debonding of Steel and CFRP Strips Externally Bonded to Concrete in the Presence of Embedded Shear Connectors
title_sort experimental study on the debonding of steel and cfrp strips externally bonded to concrete in the presence of embedded shear connectors
publisher Springer Verlag
publishDate 2023
_version_ 1806427277996589056