Fault detection and analysis in nuclear research facility using artificial intelligence methods

In this article, an online detection of transducer and actuator condition is discussed. A case study is on the reading of area radiation monitor (ARM) installed at the chimney of PUSPATI TRIGA nuclear reactor building, located at Bangi, Malaysia. There are at least five categories of abnormal ARM re...

Full description

Saved in:
Bibliographic Details
Main Authors: Ghazali A.B., Ibrahim M.M.
Other Authors: 56727852400
Format: Conference Paper
Published: American Institute of Physics Inc. 2023
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Tenaga Nasional
id my.uniten.dspace-22861
record_format dspace
spelling my.uniten.dspace-228612023-05-29T14:12:49Z Fault detection and analysis in nuclear research facility using artificial intelligence methods Ghazali A.B. Ibrahim M.M. 56727852400 55700571500 In this article, an online detection of transducer and actuator condition is discussed. A case study is on the reading of area radiation monitor (ARM) installed at the chimney of PUSPATI TRIGA nuclear reactor building, located at Bangi, Malaysia. There are at least five categories of abnormal ARM reading that could happen during the transducer failure, namely either the reading becomes very high, or very low/zero, or with high fluctuation and noise. Moreover, the reading may be significantly higher or significantly lower as compared to the normal reading. An artificial neural network (ANN) and adaptive neuro-fuzzy inference system (ANFIS) are good methods for modeling this plant dynamics. The failure of equipment is based on ARM reading so it is then to compare with the estimated ARM data from ANN/ANFIS function. The failure categories in either 'yes' or 'no' state are obtained from a comparison between the actual online data and the estimated output from ANN/ANFIS function. It is found that this system design can correctly report the condition of ARM equipment in a simulated environment and later be implemented for online monitoring. This approach can also be extended to other transducers, such as the temperature profile of reactor core and also to include other critical actuator conditions such as the valves and pumps in the reactor facility provided that the failure symptoms are clearly defined. � 2016 AIP Publishing LLC. Final 2023-05-29T06:12:49Z 2023-05-29T06:12:49Z 2016 Conference Paper 10.1063/1.4940079 2-s2.0-84984577789 https://www.scopus.com/inward/record.uri?eid=2-s2.0-84984577789&doi=10.1063%2f1.4940079&partnerID=40&md5=c3cfbe2a27d8d195df49dbd5657a943f https://irepository.uniten.edu.my/handle/123456789/22861 1704 30010 All Open Access, Bronze American Institute of Physics Inc. Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description In this article, an online detection of transducer and actuator condition is discussed. A case study is on the reading of area radiation monitor (ARM) installed at the chimney of PUSPATI TRIGA nuclear reactor building, located at Bangi, Malaysia. There are at least five categories of abnormal ARM reading that could happen during the transducer failure, namely either the reading becomes very high, or very low/zero, or with high fluctuation and noise. Moreover, the reading may be significantly higher or significantly lower as compared to the normal reading. An artificial neural network (ANN) and adaptive neuro-fuzzy inference system (ANFIS) are good methods for modeling this plant dynamics. The failure of equipment is based on ARM reading so it is then to compare with the estimated ARM data from ANN/ANFIS function. The failure categories in either 'yes' or 'no' state are obtained from a comparison between the actual online data and the estimated output from ANN/ANFIS function. It is found that this system design can correctly report the condition of ARM equipment in a simulated environment and later be implemented for online monitoring. This approach can also be extended to other transducers, such as the temperature profile of reactor core and also to include other critical actuator conditions such as the valves and pumps in the reactor facility provided that the failure symptoms are clearly defined. � 2016 AIP Publishing LLC.
author2 56727852400
author_facet 56727852400
Ghazali A.B.
Ibrahim M.M.
format Conference Paper
author Ghazali A.B.
Ibrahim M.M.
spellingShingle Ghazali A.B.
Ibrahim M.M.
Fault detection and analysis in nuclear research facility using artificial intelligence methods
author_sort Ghazali A.B.
title Fault detection and analysis in nuclear research facility using artificial intelligence methods
title_short Fault detection and analysis in nuclear research facility using artificial intelligence methods
title_full Fault detection and analysis in nuclear research facility using artificial intelligence methods
title_fullStr Fault detection and analysis in nuclear research facility using artificial intelligence methods
title_full_unstemmed Fault detection and analysis in nuclear research facility using artificial intelligence methods
title_sort fault detection and analysis in nuclear research facility using artificial intelligence methods
publisher American Institute of Physics Inc.
publishDate 2023
_version_ 1806428074178248704