Development of condition rating of shotcrete lining of hydroelectric power station based on condition assessment of its distresses

Tunnel underground structure often exposed to an extensive deterioration especially on the tunnel lining. Water leakage is the most common distress occurred in tunnel subsequently causing other distresses to form. After providing services over years, evaluation of shotcrete tunnel lining of undergro...

Full description

Saved in:
Bibliographic Details
Main Authors: Usman F., Banuar N., Muda Z.C.
Other Authors: 55812540000
Format: Article
Published: Asian Research Publishing Network 2023
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Tenaga Nasional
id my.uniten.dspace-22914
record_format dspace
spelling my.uniten.dspace-229142023-05-29T14:13:22Z Development of condition rating of shotcrete lining of hydroelectric power station based on condition assessment of its distresses Usman F. Banuar N. Muda Z.C. 55812540000 57190172735 55812444000 Tunnel underground structure often exposed to an extensive deterioration especially on the tunnel lining. Water leakage is the most common distress occurred in tunnel subsequently causing other distresses to form. After providing services over years, evaluation of shotcrete tunnel lining of underground hydroelectric power station is increasing the degree of importance to ascertain its reliability. This study is conducted to generate condition rating of distress simultaneously identify how combining distresses would affect the condition of shotcrete tunnel lining rather than presenting in a single distress rating. It can be time prohibitive to conduct an assessment to identify the causes that triggered the deterioration of shotcrete using visual inspection and non-destructive test including electrical resistivity and ground penetrating radar. The results from these tests will then be analyzed using statistical analysis to determine every respective condition. There are four distresses were identified as major contribution to the deterioration of shotcrete lining involving water leakage, crack, water saturated zone and rock fractured. Based on the findings, the condition rating that has been developed able to represent more conscious descriptive meaning to each distress. Even tough when it is compared to the single parameter of assessment i.e. the water leakage, there are average different ratings from 4% to 15%. � 2006-2016 Asian Research Publishing Network (ARPN). All rights reserved. Final 2023-05-29T06:13:21Z 2023-05-29T06:13:21Z 2016 Article 2-s2.0-85009230907 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85009230907&partnerID=40&md5=3f42f3e847eb8b1f6ac38e48893bfc32 https://irepository.uniten.edu.my/handle/123456789/22914 11 24 14156 14161 Asian Research Publishing Network Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description Tunnel underground structure often exposed to an extensive deterioration especially on the tunnel lining. Water leakage is the most common distress occurred in tunnel subsequently causing other distresses to form. After providing services over years, evaluation of shotcrete tunnel lining of underground hydroelectric power station is increasing the degree of importance to ascertain its reliability. This study is conducted to generate condition rating of distress simultaneously identify how combining distresses would affect the condition of shotcrete tunnel lining rather than presenting in a single distress rating. It can be time prohibitive to conduct an assessment to identify the causes that triggered the deterioration of shotcrete using visual inspection and non-destructive test including electrical resistivity and ground penetrating radar. The results from these tests will then be analyzed using statistical analysis to determine every respective condition. There are four distresses were identified as major contribution to the deterioration of shotcrete lining involving water leakage, crack, water saturated zone and rock fractured. Based on the findings, the condition rating that has been developed able to represent more conscious descriptive meaning to each distress. Even tough when it is compared to the single parameter of assessment i.e. the water leakage, there are average different ratings from 4% to 15%. � 2006-2016 Asian Research Publishing Network (ARPN). All rights reserved.
author2 55812540000
author_facet 55812540000
Usman F.
Banuar N.
Muda Z.C.
format Article
author Usman F.
Banuar N.
Muda Z.C.
spellingShingle Usman F.
Banuar N.
Muda Z.C.
Development of condition rating of shotcrete lining of hydroelectric power station based on condition assessment of its distresses
author_sort Usman F.
title Development of condition rating of shotcrete lining of hydroelectric power station based on condition assessment of its distresses
title_short Development of condition rating of shotcrete lining of hydroelectric power station based on condition assessment of its distresses
title_full Development of condition rating of shotcrete lining of hydroelectric power station based on condition assessment of its distresses
title_fullStr Development of condition rating of shotcrete lining of hydroelectric power station based on condition assessment of its distresses
title_full_unstemmed Development of condition rating of shotcrete lining of hydroelectric power station based on condition assessment of its distresses
title_sort development of condition rating of shotcrete lining of hydroelectric power station based on condition assessment of its distresses
publisher Asian Research Publishing Network
publishDate 2023
_version_ 1806423376824107008