CFD investigation on the effect of varying fire sprinkler orientation on sprinkler activation time
Water sprinkler system is considered one of the main water-based fire suppression systems. Due to the turbulent nature of fire, prediction of water sprinklers activation time required performing numerous experiments and tests to understand the nature of the parameters involved in changing the activa...
Saved in:
Main Authors: | , , |
---|---|
Other Authors: | |
Format: | Article |
Published: |
Asian Research Publishing Network
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Tenaga Nasional |
id |
my.uniten.dspace-22916 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-229162023-05-29T14:13:23Z CFD investigation on the effect of varying fire sprinkler orientation on sprinkler activation time Nasif M.S. Fekry M. Ismail F.B. 55188481100 57192662727 58027086700 Water sprinkler system is considered one of the main water-based fire suppression systems. Due to the turbulent nature of fire, prediction of water sprinklers activation time required performing numerous experiments and tests to understand the nature of the parameters involved in changing the activation time. It was noticed that the angle where the sprinkler arms are oriented towards the hot gas jet resulting from a fire had a great impact on the activation time of the sprinkler. In this research the orientation of the sprinkler's arm was changed by using Computational Fluid Dynamics (CFD) simulation. It was found that changing the sprinkler arm angle from perpendicular to the flow (90�) to 60�, 30� and parallel to the flow (0�) has resulted in increasing t sprinkler activation time by about 8%, 84%, and 163% respectively. The effect of sprinkler activation time variation was investigated on stacked wood pallets heat release rate. It was found that with a parallel orientation the fire is allowed to grow 2.5 times more in terms of Heat Release Rate (HRR) than with perpendicular orientation. � 2006-2016 Asian Research Publishing Network (ARPN). Final 2023-05-29T06:13:23Z 2023-05-29T06:13:23Z 2016 Article 2-s2.0-85007273692 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85007273692&partnerID=40&md5=f6a848e67b2602b3c8cc11cbe54e9eed https://irepository.uniten.edu.my/handle/123456789/22916 11 22 12919 12922 Asian Research Publishing Network Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
Water sprinkler system is considered one of the main water-based fire suppression systems. Due to the turbulent nature of fire, prediction of water sprinklers activation time required performing numerous experiments and tests to understand the nature of the parameters involved in changing the activation time. It was noticed that the angle where the sprinkler arms are oriented towards the hot gas jet resulting from a fire had a great impact on the activation time of the sprinkler. In this research the orientation of the sprinkler's arm was changed by using Computational Fluid Dynamics (CFD) simulation. It was found that changing the sprinkler arm angle from perpendicular to the flow (90�) to 60�, 30� and parallel to the flow (0�) has resulted in increasing t sprinkler activation time by about 8%, 84%, and 163% respectively. The effect of sprinkler activation time variation was investigated on stacked wood pallets heat release rate. It was found that with a parallel orientation the fire is allowed to grow 2.5 times more in terms of Heat Release Rate (HRR) than with perpendicular orientation. � 2006-2016 Asian Research Publishing Network (ARPN). |
author2 |
55188481100 |
author_facet |
55188481100 Nasif M.S. Fekry M. Ismail F.B. |
format |
Article |
author |
Nasif M.S. Fekry M. Ismail F.B. |
spellingShingle |
Nasif M.S. Fekry M. Ismail F.B. CFD investigation on the effect of varying fire sprinkler orientation on sprinkler activation time |
author_sort |
Nasif M.S. |
title |
CFD investigation on the effect of varying fire sprinkler orientation on sprinkler activation time |
title_short |
CFD investigation on the effect of varying fire sprinkler orientation on sprinkler activation time |
title_full |
CFD investigation on the effect of varying fire sprinkler orientation on sprinkler activation time |
title_fullStr |
CFD investigation on the effect of varying fire sprinkler orientation on sprinkler activation time |
title_full_unstemmed |
CFD investigation on the effect of varying fire sprinkler orientation on sprinkler activation time |
title_sort |
cfd investigation on the effect of varying fire sprinkler orientation on sprinkler activation time |
publisher |
Asian Research Publishing Network |
publishDate |
2023 |
_version_ |
1806425857953103872 |