Experimental investigation of CFRP strengthened I-shaped cold formed steel beams

Cold formed steel differ from hot rolled steel by its lesser thickness and weight. The cold formed steel applicable in roof purlin, pipe racks and wall panels etc. Due its lesser wall thickness the cold formed steel member subjected to buckling. The enhancement of load carrying capacity of the cold...

Full description

Saved in:
Bibliographic Details
Main Authors: Chakravarthy N., Naganathan S., Aun J.T.H., Kalavagunta S., Mustapha K.N., Veena T.R.
Other Authors: 57194602818
Format: Article
Published: Penerbit UTM Press 2023
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Tenaga Nasional
id my.uniten.dspace-23173
record_format dspace
spelling my.uniten.dspace-231732023-05-29T14:38:11Z Experimental investigation of CFRP strengthened I-shaped cold formed steel beams Chakravarthy N. Naganathan S. Aun J.T.H. Kalavagunta S. Mustapha K.N. Veena T.R. 57194602818 30267872100 57194606131 55695387900 26032672000 57191986079 Cold formed steel differ from hot rolled steel by its lesser thickness and weight. The cold formed steel applicable in roof purlin, pipe racks and wall panels etc. Due its lesser wall thickness the cold formed steel member subjected to buckling. The enhancement of load carrying capacity of the cold formed steel member can be achieved by external strengthening of CFRP. In this study cold formed channel members connected back to back to form I shaped cross section using screws. These built up beam members were 300mm, 400mm and 500mm in length with 100mm screw spacing and edge distance of 50mm were chosen for testing. CFRP fabric cut according to length, width of built up beams and wrapped outer surface of beam using epoxy resin. Experiments were carried out in two sets firstly plain built up beams and secondly CFRP wrapped beams. The test results shows that increased load carrying capacity and reduction in deflection due to CFRP strengthening. Experimental results were compared with AISI standards which are in good agreement. Experimental results shows that CFRP strengthening is economic and reliable. � 2017 Penerbit UTM Press. All rights reserved. Final 2023-05-29T06:38:10Z 2023-05-29T06:38:10Z 2017 Article 10.11113/jt.v79.10255 2-s2.0-85021071375 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85021071375&doi=10.11113%2fjt.v79.10255&partnerID=40&md5=0328c046f6a44b7d7a8df60e60e07325 https://irepository.uniten.edu.my/handle/123456789/23173 79 5 83 89 Penerbit UTM Press Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description Cold formed steel differ from hot rolled steel by its lesser thickness and weight. The cold formed steel applicable in roof purlin, pipe racks and wall panels etc. Due its lesser wall thickness the cold formed steel member subjected to buckling. The enhancement of load carrying capacity of the cold formed steel member can be achieved by external strengthening of CFRP. In this study cold formed channel members connected back to back to form I shaped cross section using screws. These built up beam members were 300mm, 400mm and 500mm in length with 100mm screw spacing and edge distance of 50mm were chosen for testing. CFRP fabric cut according to length, width of built up beams and wrapped outer surface of beam using epoxy resin. Experiments were carried out in two sets firstly plain built up beams and secondly CFRP wrapped beams. The test results shows that increased load carrying capacity and reduction in deflection due to CFRP strengthening. Experimental results were compared with AISI standards which are in good agreement. Experimental results shows that CFRP strengthening is economic and reliable. � 2017 Penerbit UTM Press. All rights reserved.
author2 57194602818
author_facet 57194602818
Chakravarthy N.
Naganathan S.
Aun J.T.H.
Kalavagunta S.
Mustapha K.N.
Veena T.R.
format Article
author Chakravarthy N.
Naganathan S.
Aun J.T.H.
Kalavagunta S.
Mustapha K.N.
Veena T.R.
spellingShingle Chakravarthy N.
Naganathan S.
Aun J.T.H.
Kalavagunta S.
Mustapha K.N.
Veena T.R.
Experimental investigation of CFRP strengthened I-shaped cold formed steel beams
author_sort Chakravarthy N.
title Experimental investigation of CFRP strengthened I-shaped cold formed steel beams
title_short Experimental investigation of CFRP strengthened I-shaped cold formed steel beams
title_full Experimental investigation of CFRP strengthened I-shaped cold formed steel beams
title_fullStr Experimental investigation of CFRP strengthened I-shaped cold formed steel beams
title_full_unstemmed Experimental investigation of CFRP strengthened I-shaped cold formed steel beams
title_sort experimental investigation of cfrp strengthened i-shaped cold formed steel beams
publisher Penerbit UTM Press
publishDate 2023
_version_ 1806427632073441280