The effect on ampacity for multiple cable crossing and mitigation to improve its ampacity
Cables; Computer software; Underground cables; Ampacity; Computer simulation technology (CST); High voltage cable; Localized heating; Medium voltage cables; Parallel configuration; Planning stages; Temperature rise; Crossings (pipe and cable)
Saved in:
Main Authors: | , , , , , , , |
---|---|
Other Authors: | |
Format: | Conference Paper |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Tenaga Nasional |
id |
my.uniten.dspace-23185 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-231852023-05-29T14:38:16Z The effect on ampacity for multiple cable crossing and mitigation to improve its ampacity Radzi A.S. Arifin N.A.N. Anthony T.M. Aida Z. Azlina N. Raj A. Chakrabarty C. Syaza N. 57194946234 57194941391 26422816100 57194946934 57194939638 57189492851 6701755282 57194942733 Cables; Computer software; Underground cables; Ampacity; Computer simulation technology (CST); High voltage cable; Localized heating; Medium voltage cables; Parallel configuration; Planning stages; Temperature rise; Crossings (pipe and cable) At some point underground, there are high voltage cables and medium voltage cables that will be crossing each other. Many utilities do not consider or ignore the derating of ampacity caused by multiple cables crossing. In IEC 60287-3-3: Calculation of Power Ratings - Cables Crossing External Heat Sources, the ampacity rating for only two crossing cables is calculated. This paper hence computes the ampacity for multiple cables crossing. Three circuits of high voltage cables crossing three circuits of medium voltage cables were modeled using Computer Simulation Technology (CST) Software. Both the cables were in the parallel configuration with the distance between the circuits and depth of buried varied. Significant temperature rise was found at the point of crossing. If the ampacity were not derated, the temperature exceeds 90�C at the core and becomes unacceptable for the insulation at the point of crossing which causes localized dielectric ageing which may lead to premature cable failures. By extracting the temperature results along the cables at the point of crossing and its vicinity, the localized over-heating at the point of crossing were shown. Also, by adding a steel block between the cables at point of crossing, ampacity can be improved. Hence, this is an important factor that needed to be considered during planning stage. � 2016 IEEE. Final 2023-05-29T06:38:16Z 2023-05-29T06:38:16Z 2017 Conference Paper 10.1109/PECON.2016.7951577 2-s2.0-85024375435 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85024375435&doi=10.1109%2fPECON.2016.7951577&partnerID=40&md5=0c5edfd25b4a50dded44dfddf8e97bb6 https://irepository.uniten.edu.my/handle/123456789/23185 7951577 301 305 Institute of Electrical and Electronics Engineers Inc. Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
Cables; Computer software; Underground cables; Ampacity; Computer simulation technology (CST); High voltage cable; Localized heating; Medium voltage cables; Parallel configuration; Planning stages; Temperature rise; Crossings (pipe and cable) |
author2 |
57194946234 |
author_facet |
57194946234 Radzi A.S. Arifin N.A.N. Anthony T.M. Aida Z. Azlina N. Raj A. Chakrabarty C. Syaza N. |
format |
Conference Paper |
author |
Radzi A.S. Arifin N.A.N. Anthony T.M. Aida Z. Azlina N. Raj A. Chakrabarty C. Syaza N. |
spellingShingle |
Radzi A.S. Arifin N.A.N. Anthony T.M. Aida Z. Azlina N. Raj A. Chakrabarty C. Syaza N. The effect on ampacity for multiple cable crossing and mitigation to improve its ampacity |
author_sort |
Radzi A.S. |
title |
The effect on ampacity for multiple cable crossing and mitigation to improve its ampacity |
title_short |
The effect on ampacity for multiple cable crossing and mitigation to improve its ampacity |
title_full |
The effect on ampacity for multiple cable crossing and mitigation to improve its ampacity |
title_fullStr |
The effect on ampacity for multiple cable crossing and mitigation to improve its ampacity |
title_full_unstemmed |
The effect on ampacity for multiple cable crossing and mitigation to improve its ampacity |
title_sort |
effect on ampacity for multiple cable crossing and mitigation to improve its ampacity |
publisher |
Institute of Electrical and Electronics Engineers Inc. |
publishDate |
2023 |
_version_ |
1806427861830074368 |