Effect of Step Height on the Aeration Efficiency of Cascade Aerator System Using Particle Image Velocimetry

Air entrainment; Efficiency; Flow visualization; System theory; Velocimeters; Velocity measurement; Water aeration; Water filtration; Aeration efficiencies; Laboratory studies; Mass flow rate; Particle image velocimetries; Physical model; Turbulence effect; Velocity profiles; Water filtration system...

Full description

Saved in:
Bibliographic Details
Main Authors: Azman A., Zawawi M.H., Hassan N.H., Abas A., Razak N.A., Mazlan A.Z.A., Mohd Remy Rozainy M.A.Z.
Other Authors: 57210094312
Format: Conference Paper
Published: EDP Sciences 2023
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Tenaga Nasional
id my.uniten.dspace-23649
record_format dspace
spelling my.uniten.dspace-236492023-05-29T14:50:45Z Effect of Step Height on the Aeration Efficiency of Cascade Aerator System Using Particle Image Velocimetry Azman A. Zawawi M.H. Hassan N.H. Abas A. Razak N.A. Mazlan A.Z.A. Mohd Remy Rozainy M.A.Z. 57210094312 39162217600 57204683370 56893346700 52364538900 57216895962 57193313971 Air entrainment; Efficiency; Flow visualization; System theory; Velocimeters; Velocity measurement; Water aeration; Water filtration; Aeration efficiencies; Laboratory studies; Mass flow rate; Particle image velocimetries; Physical model; Turbulence effect; Velocity profiles; Water filtration systems; Water treatment Aeration is an important parameter in water filtration system as it allows the transfer of oxygen to water through turbulence effect which subsequently increases air entrainment in the water. For water treatment application, aeration efficiency is measured to ensure continuous re-oxygenation of the unfiltered water. Aside from aeration, this paper also studies the flow patterns through the use of particle image velocimetry (PIV) setup. Through the use of real scale down physical model laboratory study is performed using PIV to obtain the velocity profile. These velocity profiles will then be used to calculate the aeration efficiency of the water in a cascade aerator system. Based on the findings, the aeration efficiency obtained from the PIV experiment has a maximum value at the lowest point of the cascade aerator system with a value of 0.0139 due to increase in mass flow rate as it moves through the steps with velocity of 0.418 m/s. Therefore, in the design of a cascade aerator system, it is advisable to increase the number of steps since it will increase the aeration efficiency of the system. � 2018 The Authors, published by EDP Sciences. Final 2023-05-29T06:50:45Z 2023-05-29T06:50:45Z 2018 Conference Paper 10.1051/matecconf/201821704005 2-s2.0-85056615414 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85056615414&doi=10.1051%2fmatecconf%2f201821704005&partnerID=40&md5=c750c31ed41e450c6885258d5a2ffdb2 https://irepository.uniten.edu.my/handle/123456789/23649 217 4005 All Open Access, Gold, Green EDP Sciences Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description Air entrainment; Efficiency; Flow visualization; System theory; Velocimeters; Velocity measurement; Water aeration; Water filtration; Aeration efficiencies; Laboratory studies; Mass flow rate; Particle image velocimetries; Physical model; Turbulence effect; Velocity profiles; Water filtration systems; Water treatment
author2 57210094312
author_facet 57210094312
Azman A.
Zawawi M.H.
Hassan N.H.
Abas A.
Razak N.A.
Mazlan A.Z.A.
Mohd Remy Rozainy M.A.Z.
format Conference Paper
author Azman A.
Zawawi M.H.
Hassan N.H.
Abas A.
Razak N.A.
Mazlan A.Z.A.
Mohd Remy Rozainy M.A.Z.
spellingShingle Azman A.
Zawawi M.H.
Hassan N.H.
Abas A.
Razak N.A.
Mazlan A.Z.A.
Mohd Remy Rozainy M.A.Z.
Effect of Step Height on the Aeration Efficiency of Cascade Aerator System Using Particle Image Velocimetry
author_sort Azman A.
title Effect of Step Height on the Aeration Efficiency of Cascade Aerator System Using Particle Image Velocimetry
title_short Effect of Step Height on the Aeration Efficiency of Cascade Aerator System Using Particle Image Velocimetry
title_full Effect of Step Height on the Aeration Efficiency of Cascade Aerator System Using Particle Image Velocimetry
title_fullStr Effect of Step Height on the Aeration Efficiency of Cascade Aerator System Using Particle Image Velocimetry
title_full_unstemmed Effect of Step Height on the Aeration Efficiency of Cascade Aerator System Using Particle Image Velocimetry
title_sort effect of step height on the aeration efficiency of cascade aerator system using particle image velocimetry
publisher EDP Sciences
publishDate 2023
_version_ 1806428074899668992