Application of microwave-assisted extraction coupled with dispersive liquid-liquid microextraction for the determination of polycyclic aromatic hydrocarbons in vegetables [Aplikasi pengekstrakan berbantukan mikrogelombang gandingan dengan pengekstrakan mikro cecair-cecair serakan bagi penentukan hidrokarbon aromatik polisiklik dalam sayur-sayuran]
Microwave-assisted extraction (MAE) coupled with dispersive liquid-liquid microextraction (DLLME) followed by gas-chromatography flame ionization detector (GC-FID) for the determination of 13 PAHs in vegetable samples was developed in this study. The analytical performances of the optimized DLLME an...
Saved in:
Main Authors: | , , |
---|---|
Other Authors: | |
Format: | Article |
Published: |
Malaysian Society of Analytical Sciences
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Tenaga Nasional |
id |
my.uniten.dspace-25770 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-257702023-05-29T16:14:04Z Application of microwave-assisted extraction coupled with dispersive liquid-liquid microextraction for the determination of polycyclic aromatic hydrocarbons in vegetables [Aplikasi pengekstrakan berbantukan mikrogelombang gandingan dengan pengekstrakan mikro cecair-cecair serakan bagi penentukan hidrokarbon aromatik polisiklik dalam sayur-sayuran] Kin C.M. Hwang T.Y. Shing W.L. 57215027085 57212768427 55819849800 Microwave-assisted extraction (MAE) coupled with dispersive liquid-liquid microextraction (DLLME) followed by gas-chromatography flame ionization detector (GC-FID) for the determination of 13 PAHs in vegetable samples was developed in this study. The analytical performances of the optimized DLLME and MAE-DLLME including limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, relative extraction recovery and relative extraction factor were validated and compared. The LOD of DLLME and MAE-DLLME were in the range of 0.040-0.400 and 0.0200-0.080 �g/L, respectively. For DLLME, precision and accuracy were 1.22-7.50% (RSD) and 71.77% to 90.93%, respectively; while for MAE-DLLME, were 0.77%-3.07% (RSD) and 83.65-98.42%, respectively. The relative extraction recovery was improved from 70.81% � 85.41% in DLLME to 85.79%-99.61% in MAE-DLLME. The relative enrichment factors were ranged from 126-156 and 165 to 202 for DLLME and MAE-DLLME, respectively. The volume of extraction solvent was reduced from 50 � L to 30 �L in MAE-DLLME. The overall analytical performances of MAE-DLLME is better than DLLME. The application of proposed MAE-DLLME in real samples was also investigated and discussed. � 2020, Malaysian Society of Analytical Sciences. All rights reserved. Final 2023-05-29T08:14:04Z 2023-05-29T08:14:04Z 2020 Article 2-s2.0-85079716131 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85079716131&partnerID=40&md5=642fa21c67c80e78a57ed2f1be051a48 https://irepository.uniten.edu.my/handle/123456789/25770 24 1 53 61 Malaysian Society of Analytical Sciences Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
Microwave-assisted extraction (MAE) coupled with dispersive liquid-liquid microextraction (DLLME) followed by gas-chromatography flame ionization detector (GC-FID) for the determination of 13 PAHs in vegetable samples was developed in this study. The analytical performances of the optimized DLLME and MAE-DLLME including limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, relative extraction recovery and relative extraction factor were validated and compared. The LOD of DLLME and MAE-DLLME were in the range of 0.040-0.400 and 0.0200-0.080 �g/L, respectively. For DLLME, precision and accuracy were 1.22-7.50% (RSD) and 71.77% to 90.93%, respectively; while for MAE-DLLME, were 0.77%-3.07% (RSD) and 83.65-98.42%, respectively. The relative extraction recovery was improved from 70.81% � 85.41% in DLLME to 85.79%-99.61% in MAE-DLLME. The relative enrichment factors were ranged from 126-156 and 165 to 202 for DLLME and MAE-DLLME, respectively. The volume of extraction solvent was reduced from 50 � L to 30 �L in MAE-DLLME. The overall analytical performances of MAE-DLLME is better than DLLME. The application of proposed MAE-DLLME in real samples was also investigated and discussed. � 2020, Malaysian Society of Analytical Sciences. All rights reserved. |
author2 |
57215027085 |
author_facet |
57215027085 Kin C.M. Hwang T.Y. Shing W.L. |
format |
Article |
author |
Kin C.M. Hwang T.Y. Shing W.L. |
spellingShingle |
Kin C.M. Hwang T.Y. Shing W.L. Application of microwave-assisted extraction coupled with dispersive liquid-liquid microextraction for the determination of polycyclic aromatic hydrocarbons in vegetables [Aplikasi pengekstrakan berbantukan mikrogelombang gandingan dengan pengekstrakan mikro cecair-cecair serakan bagi penentukan hidrokarbon aromatik polisiklik dalam sayur-sayuran] |
author_sort |
Kin C.M. |
title |
Application of microwave-assisted extraction coupled with dispersive liquid-liquid microextraction for the determination of polycyclic aromatic hydrocarbons in vegetables [Aplikasi pengekstrakan berbantukan mikrogelombang gandingan dengan pengekstrakan mikro cecair-cecair serakan bagi penentukan hidrokarbon aromatik polisiklik dalam sayur-sayuran] |
title_short |
Application of microwave-assisted extraction coupled with dispersive liquid-liquid microextraction for the determination of polycyclic aromatic hydrocarbons in vegetables [Aplikasi pengekstrakan berbantukan mikrogelombang gandingan dengan pengekstrakan mikro cecair-cecair serakan bagi penentukan hidrokarbon aromatik polisiklik dalam sayur-sayuran] |
title_full |
Application of microwave-assisted extraction coupled with dispersive liquid-liquid microextraction for the determination of polycyclic aromatic hydrocarbons in vegetables [Aplikasi pengekstrakan berbantukan mikrogelombang gandingan dengan pengekstrakan mikro cecair-cecair serakan bagi penentukan hidrokarbon aromatik polisiklik dalam sayur-sayuran] |
title_fullStr |
Application of microwave-assisted extraction coupled with dispersive liquid-liquid microextraction for the determination of polycyclic aromatic hydrocarbons in vegetables [Aplikasi pengekstrakan berbantukan mikrogelombang gandingan dengan pengekstrakan mikro cecair-cecair serakan bagi penentukan hidrokarbon aromatik polisiklik dalam sayur-sayuran] |
title_full_unstemmed |
Application of microwave-assisted extraction coupled with dispersive liquid-liquid microextraction for the determination of polycyclic aromatic hydrocarbons in vegetables [Aplikasi pengekstrakan berbantukan mikrogelombang gandingan dengan pengekstrakan mikro cecair-cecair serakan bagi penentukan hidrokarbon aromatik polisiklik dalam sayur-sayuran] |
title_sort |
application of microwave-assisted extraction coupled with dispersive liquid-liquid microextraction for the determination of polycyclic aromatic hydrocarbons in vegetables [aplikasi pengekstrakan berbantukan mikrogelombang gandingan dengan pengekstrakan mikro cecair-cecair serakan bagi penentukan hidrokarbon aromatik polisiklik dalam sayur-sayuran] |
publisher |
Malaysian Society of Analytical Sciences |
publishDate |
2023 |
_version_ |
1806426025357213696 |