Portable NIR Spectroscopy Measuring Device for Transformer Oil DBPC Inhibitor Analysis
Electric transformer testing; Infrared devices; Mean square error; Near infrared spectroscopy; Power transformers; Voltage measurement; Conventional techniques; Inhibitor concentration; New mathematical model; Optical measuring devices; Performance comparison; Prototype verification; Root mean squar...
Saved in:
Main Authors: | , , , , , , |
---|---|
Other Authors: | |
Format: | Article |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Tenaga Nasional |
id |
my.uniten.dspace-26229 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-262292023-05-29T17:08:01Z Portable NIR Spectroscopy Measuring Device for Transformer Oil DBPC Inhibitor Analysis Leong Y.S. Ker P.J. Hasnul M.H. Khamis M.A. Hannan M.A. Jamaludin M.Z. Looe H.M. 57202929965 37461740800 57207576846 57204588662 7103014445 57216839721 6507460925 Electric transformer testing; Infrared devices; Mean square error; Near infrared spectroscopy; Power transformers; Voltage measurement; Conventional techniques; Inhibitor concentration; New mathematical model; Optical measuring devices; Performance comparison; Prototype verification; Root mean square errors; Transformer oil samples; Oil filled transformers Monitoring the insulation system of power transformers is crucial in ensuring power transformers are operating in optimal conditions. Given the nondirect and destructive nature of conventional techniques, optical techniques have prevailed to be an effective alternative to monitor the condition of the insulation system. The recent development of small and compact optical components has also contributed to the utilization of optical techniques in onsite testing and online monitoring application. Therefore, this work proposed the measurement of inhibitor concentration in transformer oil by using a portable optical measuring device that utilizes near-infrared spectroscopy. The fundamental studies of measuring inhibitor in transformer oil by using a newly discovered wavelength at 1403 nm were validated, and its adaptation to a portable optical measuring device was discussed. A new mathematical model was formulated to estimate the inhibitor concentration in transformer oil samples on the basis of data obtained from the photodetector. Measurements and the conventional technique were conducted for performance comparison and prototype verification. Results showed a root-mean-square-error of 0.01708 and an average error of 2.11%. This proposed prototype opens up opportunities in onsite testing and online monitoring of inhibitor content concentration in transformer oil. � 1972-2012 IEEE. Final 2023-05-29T09:08:01Z 2023-05-29T09:08:01Z 2021 Article 10.1109/TIA.2021.3057357 2-s2.0-85101441112 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85101441112&doi=10.1109%2fTIA.2021.3057357&partnerID=40&md5=e02345451b7cde1c6465ccacb9fe148e https://irepository.uniten.edu.my/handle/123456789/26229 57 3 9347793 2114 2119 Institute of Electrical and Electronics Engineers Inc. Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
Electric transformer testing; Infrared devices; Mean square error; Near infrared spectroscopy; Power transformers; Voltage measurement; Conventional techniques; Inhibitor concentration; New mathematical model; Optical measuring devices; Performance comparison; Prototype verification; Root mean square errors; Transformer oil samples; Oil filled transformers |
author2 |
57202929965 |
author_facet |
57202929965 Leong Y.S. Ker P.J. Hasnul M.H. Khamis M.A. Hannan M.A. Jamaludin M.Z. Looe H.M. |
format |
Article |
author |
Leong Y.S. Ker P.J. Hasnul M.H. Khamis M.A. Hannan M.A. Jamaludin M.Z. Looe H.M. |
spellingShingle |
Leong Y.S. Ker P.J. Hasnul M.H. Khamis M.A. Hannan M.A. Jamaludin M.Z. Looe H.M. Portable NIR Spectroscopy Measuring Device for Transformer Oil DBPC Inhibitor Analysis |
author_sort |
Leong Y.S. |
title |
Portable NIR Spectroscopy Measuring Device for Transformer Oil DBPC Inhibitor Analysis |
title_short |
Portable NIR Spectroscopy Measuring Device for Transformer Oil DBPC Inhibitor Analysis |
title_full |
Portable NIR Spectroscopy Measuring Device for Transformer Oil DBPC Inhibitor Analysis |
title_fullStr |
Portable NIR Spectroscopy Measuring Device for Transformer Oil DBPC Inhibitor Analysis |
title_full_unstemmed |
Portable NIR Spectroscopy Measuring Device for Transformer Oil DBPC Inhibitor Analysis |
title_sort |
portable nir spectroscopy measuring device for transformer oil dbpc inhibitor analysis |
publisher |
Institute of Electrical and Electronics Engineers Inc. |
publishDate |
2023 |
_version_ |
1806428367570862080 |