Study of static voltage stability index as an indicator for under voltage load shedding schemes
Under Voltage Load Shedding (UVLS) has been successfully deployed in many systems throughout the world to protect local systems from voltage collapse. This is particularly true if the system conditions and the contingencies leading to voltage instabilities are of low probability, but would result in...
Saved in:
Main Authors: | , , , , , |
---|---|
Other Authors: | |
Format: | Conference paper |
Published: |
2023
|
Subjects: | |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Tenaga Nasional |
id |
my.uniten.dspace-29675 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-296752023-12-28T15:30:44Z Study of static voltage stability index as an indicator for under voltage load shedding schemes Zahidi R.A. Abidin I.Z. Hashim H. Omar Y.R. Ahmad N. Ali A.M. 35753842000 35606640500 56644250200 56600264200 57212428817 55628589769 Under voltage load shedding Voltage index Voltage stability Convergence of numerical methods Electric load shedding Power generation Sustainable development Voltage control Voltage stabilizing circuits Expert knowledge Fast voltage stability indices Load-shedding Local system Low probability Numerical verification Power grids Static voltage stability System conditions Under voltage load shedding Voltage collapse Voltage index Voltage instability Voltage stability System stability Under Voltage Load Shedding (UVLS) has been successfully deployed in many systems throughout the world to protect local systems from voltage collapse. This is particularly true if the system conditions and the contingencies leading to voltage instabilities are of low probability, but would result in serious consequences. However, the locations and how much load to shed requires expert knowledge and experience working with the power grid. This paper will present on utilizing an established index called FVSI (Fast Voltage Stability Index) to act as a numerical verification of the shedding locations. The research work done shows that the FVSI index can be used and load shedding at these points does improve the stability of the system. Final 2023-12-28T07:30:44Z 2023-12-28T07:30:44Z 2009 Conference paper 10.1109/ICEENVIRON.2009.5398637 2-s2.0-77949630691 https://www.scopus.com/inward/record.uri?eid=2-s2.0-77949630691&doi=10.1109%2fICEENVIRON.2009.5398637&partnerID=40&md5=f567b90e7df05c8488183ff00a11bba7 https://irepository.uniten.edu.my/handle/123456789/29675 5398637 256 261 Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
topic |
Under voltage load shedding Voltage index Voltage stability Convergence of numerical methods Electric load shedding Power generation Sustainable development Voltage control Voltage stabilizing circuits Expert knowledge Fast voltage stability indices Load-shedding Local system Low probability Numerical verification Power grids Static voltage stability System conditions Under voltage load shedding Voltage collapse Voltage index Voltage instability Voltage stability System stability |
spellingShingle |
Under voltage load shedding Voltage index Voltage stability Convergence of numerical methods Electric load shedding Power generation Sustainable development Voltage control Voltage stabilizing circuits Expert knowledge Fast voltage stability indices Load-shedding Local system Low probability Numerical verification Power grids Static voltage stability System conditions Under voltage load shedding Voltage collapse Voltage index Voltage instability Voltage stability System stability Zahidi R.A. Abidin I.Z. Hashim H. Omar Y.R. Ahmad N. Ali A.M. Study of static voltage stability index as an indicator for under voltage load shedding schemes |
description |
Under Voltage Load Shedding (UVLS) has been successfully deployed in many systems throughout the world to protect local systems from voltage collapse. This is particularly true if the system conditions and the contingencies leading to voltage instabilities are of low probability, but would result in serious consequences. However, the locations and how much load to shed requires expert knowledge and experience working with the power grid. This paper will present on utilizing an established index called FVSI (Fast Voltage Stability Index) to act as a numerical verification of the shedding locations. The research work done shows that the FVSI index can be used and load shedding at these points does improve the stability of the system. |
author2 |
35753842000 |
author_facet |
35753842000 Zahidi R.A. Abidin I.Z. Hashim H. Omar Y.R. Ahmad N. Ali A.M. |
format |
Conference paper |
author |
Zahidi R.A. Abidin I.Z. Hashim H. Omar Y.R. Ahmad N. Ali A.M. |
author_sort |
Zahidi R.A. |
title |
Study of static voltage stability index as an indicator for under voltage load shedding schemes |
title_short |
Study of static voltage stability index as an indicator for under voltage load shedding schemes |
title_full |
Study of static voltage stability index as an indicator for under voltage load shedding schemes |
title_fullStr |
Study of static voltage stability index as an indicator for under voltage load shedding schemes |
title_full_unstemmed |
Study of static voltage stability index as an indicator for under voltage load shedding schemes |
title_sort |
study of static voltage stability index as an indicator for under voltage load shedding schemes |
publishDate |
2023 |
_version_ |
1806428449761394688 |