DSP based fuzzy and conventional overcurrent relay controller comparisons

Fuzzy logic control uses linguistic approach to solve complicated rules and ambiguous systems. This control strategy can be used to improve the overall performance of an overcurrent relay for power system protection compared to conventional relay. It is essential for a relay to work efficiently to t...

Full description

Saved in:
Bibliographic Details
Main Authors: Goh Y.L., Ramasamy A.K., Nagi F.H., Zainul Abidin A.A.
Other Authors: 36871489800
Format: Article
Published: 2023
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Tenaga Nasional
id my.uniten.dspace-29974
record_format dspace
spelling my.uniten.dspace-299742023-12-29T15:43:48Z DSP based fuzzy and conventional overcurrent relay controller comparisons Goh Y.L. Ramasamy A.K. Nagi F.H. Zainul Abidin A.A. 36871489800 16023154400 56272534200 25824750400 Fuzzy logic Bang-bang controllers Control strategies Defuzzification method Fuzzy logic control Fuzzy logic controllers Linguistic approach Performance improvements Power system protection Electric relays Fuzzy logic control uses linguistic approach to solve complicated rules and ambiguous systems. This control strategy can be used to improve the overall performance of an overcurrent relay for power system protection compared to conventional relay. It is essential for a relay to work efficiently to trip the circuit breakers in the presence of faults and at the same time proficient to coordinate well with the networks to avoid mal-operation. There are two different types of fuzzy logic control strategies proposed for the relay, the Fuzzy Logic Controller (FLC) and Fuzzy Bang-Bang Controller (FBBC). The FBBC is the same as the conventional FLC except that the defuzzification method uses largest of maxima (LOM). Comparisons between the fuzzy controllers and conventional relay are based on IEC 255-3 standard. These relays are implemented on a DSP TMS320F2812 and their performance is evaluated which is based on operation time, DSP's execution time and grading margin. The results obtained show a significant performance improvement compared to conventional relay. � 2013 Elsevier Ltd. All rights reserved. Final 2023-12-29T07:43:48Z 2023-12-29T07:43:48Z 2013 Article 10.1016/j.microrel.2013.03.015 2-s2.0-84878471919 https://www.scopus.com/inward/record.uri?eid=2-s2.0-84878471919&doi=10.1016%2fj.microrel.2013.03.015&partnerID=40&md5=dca703d6051034969601904c12af18f2 https://irepository.uniten.edu.my/handle/123456789/29974 53 7 1029 1035 Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
topic Fuzzy logic
Bang-bang controllers
Control strategies
Defuzzification method
Fuzzy logic control
Fuzzy logic controllers
Linguistic approach
Performance improvements
Power system protection
Electric relays
spellingShingle Fuzzy logic
Bang-bang controllers
Control strategies
Defuzzification method
Fuzzy logic control
Fuzzy logic controllers
Linguistic approach
Performance improvements
Power system protection
Electric relays
Goh Y.L.
Ramasamy A.K.
Nagi F.H.
Zainul Abidin A.A.
DSP based fuzzy and conventional overcurrent relay controller comparisons
description Fuzzy logic control uses linguistic approach to solve complicated rules and ambiguous systems. This control strategy can be used to improve the overall performance of an overcurrent relay for power system protection compared to conventional relay. It is essential for a relay to work efficiently to trip the circuit breakers in the presence of faults and at the same time proficient to coordinate well with the networks to avoid mal-operation. There are two different types of fuzzy logic control strategies proposed for the relay, the Fuzzy Logic Controller (FLC) and Fuzzy Bang-Bang Controller (FBBC). The FBBC is the same as the conventional FLC except that the defuzzification method uses largest of maxima (LOM). Comparisons between the fuzzy controllers and conventional relay are based on IEC 255-3 standard. These relays are implemented on a DSP TMS320F2812 and their performance is evaluated which is based on operation time, DSP's execution time and grading margin. The results obtained show a significant performance improvement compared to conventional relay. � 2013 Elsevier Ltd. All rights reserved.
author2 36871489800
author_facet 36871489800
Goh Y.L.
Ramasamy A.K.
Nagi F.H.
Zainul Abidin A.A.
format Article
author Goh Y.L.
Ramasamy A.K.
Nagi F.H.
Zainul Abidin A.A.
author_sort Goh Y.L.
title DSP based fuzzy and conventional overcurrent relay controller comparisons
title_short DSP based fuzzy and conventional overcurrent relay controller comparisons
title_full DSP based fuzzy and conventional overcurrent relay controller comparisons
title_fullStr DSP based fuzzy and conventional overcurrent relay controller comparisons
title_full_unstemmed DSP based fuzzy and conventional overcurrent relay controller comparisons
title_sort dsp based fuzzy and conventional overcurrent relay controller comparisons
publishDate 2023
_version_ 1806423359806767104