DSP based fuzzy and conventional overcurrent relay controller comparisons
Fuzzy logic control uses linguistic approach to solve complicated rules and ambiguous systems. This control strategy can be used to improve the overall performance of an overcurrent relay for power system protection compared to conventional relay. It is essential for a relay to work efficiently to t...
Saved in:
Main Authors: | , , , |
---|---|
Other Authors: | |
Format: | Article |
Published: |
2023
|
Subjects: | |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Tenaga Nasional |
id |
my.uniten.dspace-29974 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-299742023-12-29T15:43:48Z DSP based fuzzy and conventional overcurrent relay controller comparisons Goh Y.L. Ramasamy A.K. Nagi F.H. Zainul Abidin A.A. 36871489800 16023154400 56272534200 25824750400 Fuzzy logic Bang-bang controllers Control strategies Defuzzification method Fuzzy logic control Fuzzy logic controllers Linguistic approach Performance improvements Power system protection Electric relays Fuzzy logic control uses linguistic approach to solve complicated rules and ambiguous systems. This control strategy can be used to improve the overall performance of an overcurrent relay for power system protection compared to conventional relay. It is essential for a relay to work efficiently to trip the circuit breakers in the presence of faults and at the same time proficient to coordinate well with the networks to avoid mal-operation. There are two different types of fuzzy logic control strategies proposed for the relay, the Fuzzy Logic Controller (FLC) and Fuzzy Bang-Bang Controller (FBBC). The FBBC is the same as the conventional FLC except that the defuzzification method uses largest of maxima (LOM). Comparisons between the fuzzy controllers and conventional relay are based on IEC 255-3 standard. These relays are implemented on a DSP TMS320F2812 and their performance is evaluated which is based on operation time, DSP's execution time and grading margin. The results obtained show a significant performance improvement compared to conventional relay. � 2013 Elsevier Ltd. All rights reserved. Final 2023-12-29T07:43:48Z 2023-12-29T07:43:48Z 2013 Article 10.1016/j.microrel.2013.03.015 2-s2.0-84878471919 https://www.scopus.com/inward/record.uri?eid=2-s2.0-84878471919&doi=10.1016%2fj.microrel.2013.03.015&partnerID=40&md5=dca703d6051034969601904c12af18f2 https://irepository.uniten.edu.my/handle/123456789/29974 53 7 1029 1035 Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
topic |
Fuzzy logic Bang-bang controllers Control strategies Defuzzification method Fuzzy logic control Fuzzy logic controllers Linguistic approach Performance improvements Power system protection Electric relays |
spellingShingle |
Fuzzy logic Bang-bang controllers Control strategies Defuzzification method Fuzzy logic control Fuzzy logic controllers Linguistic approach Performance improvements Power system protection Electric relays Goh Y.L. Ramasamy A.K. Nagi F.H. Zainul Abidin A.A. DSP based fuzzy and conventional overcurrent relay controller comparisons |
description |
Fuzzy logic control uses linguistic approach to solve complicated rules and ambiguous systems. This control strategy can be used to improve the overall performance of an overcurrent relay for power system protection compared to conventional relay. It is essential for a relay to work efficiently to trip the circuit breakers in the presence of faults and at the same time proficient to coordinate well with the networks to avoid mal-operation. There are two different types of fuzzy logic control strategies proposed for the relay, the Fuzzy Logic Controller (FLC) and Fuzzy Bang-Bang Controller (FBBC). The FBBC is the same as the conventional FLC except that the defuzzification method uses largest of maxima (LOM). Comparisons between the fuzzy controllers and conventional relay are based on IEC 255-3 standard. These relays are implemented on a DSP TMS320F2812 and their performance is evaluated which is based on operation time, DSP's execution time and grading margin. The results obtained show a significant performance improvement compared to conventional relay. � 2013 Elsevier Ltd. All rights reserved. |
author2 |
36871489800 |
author_facet |
36871489800 Goh Y.L. Ramasamy A.K. Nagi F.H. Zainul Abidin A.A. |
format |
Article |
author |
Goh Y.L. Ramasamy A.K. Nagi F.H. Zainul Abidin A.A. |
author_sort |
Goh Y.L. |
title |
DSP based fuzzy and conventional overcurrent relay controller comparisons |
title_short |
DSP based fuzzy and conventional overcurrent relay controller comparisons |
title_full |
DSP based fuzzy and conventional overcurrent relay controller comparisons |
title_fullStr |
DSP based fuzzy and conventional overcurrent relay controller comparisons |
title_full_unstemmed |
DSP based fuzzy and conventional overcurrent relay controller comparisons |
title_sort |
dsp based fuzzy and conventional overcurrent relay controller comparisons |
publishDate |
2023 |
_version_ |
1806423359806767104 |