Condition monitoring of distribution transformer's mechanical parts using sweep frequency response analysis (SFRA)
Distribution transformer is the key element in the electricity transmission throughout the nation. Hence, serious attention for the transformer condition monitoring is a crucial. With an occurrence of short-circuit in the power system, the transformer active parts such as core and winding will exper...
Saved in:
Main Authors: | , , , , |
---|---|
Other Authors: | |
Format: | Conference Paper |
Published: |
Elsevier Ltd
2023
|
Subjects: | |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Tenaga Nasional |
id |
my.uniten.dspace-30061 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-300612024-04-18T11:05:52Z Condition monitoring of distribution transformer's mechanical parts using sweep frequency response analysis (SFRA) Ghani S.A. Thayoob Y.H.M. Ghazali Y.Z.Y. Khiar M.S.A. Chairul I.S. 56504019900 6505876050 55336569600 55336341600 55336864500 Core Distribution transformers FRA Frequency bands Short-circuit currents Winding Distribution transformer is the key element in the electricity transmission throughout the nation. Hence, serious attention for the transformer condition monitoring is a crucial. With an occurrence of short-circuit in the power system, the transformer active parts such as core and winding will experience a mechanical movement created by the electromagnetic forces. There are various types of transformer condition monitoring measurement in market, but the monitoring of the mechanical movement in transformer is still lacking. Therefore, Sweep Frequency Response Analysis (SFRA) has been introduced to assess any mechanical movement especially of the transformer's core and winding. The frequency response of the transformer provides mechanical information of core and winding conditions. The SFRA measurement results were validated using the actual transformer untanking process. � 2013 The Authors. Published by Elsevier. Final 2023-12-29T07:44:15Z 2023-12-29T07:44:15Z 2013 Conference Paper 10.1016/j.proeng.2013.12.208 2-s2.0-84899523777 https://www.scopus.com/inward/record.uri?eid=2-s2.0-84899523777&doi=10.1016%2fj.proeng.2013.12.208&partnerID=40&md5=42aac671df7caacaad8cd2854d0e20fa https://irepository.uniten.edu.my/handle/123456789/30061 68 469 476 All Open Access; Gold Open Access Elsevier Ltd Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
topic |
Core Distribution transformers FRA Frequency bands Short-circuit currents Winding |
spellingShingle |
Core Distribution transformers FRA Frequency bands Short-circuit currents Winding Ghani S.A. Thayoob Y.H.M. Ghazali Y.Z.Y. Khiar M.S.A. Chairul I.S. Condition monitoring of distribution transformer's mechanical parts using sweep frequency response analysis (SFRA) |
description |
Distribution transformer is the key element in the electricity transmission throughout the nation. Hence, serious attention for the transformer condition monitoring is a crucial. With an occurrence of short-circuit in the power system, the transformer active parts such as core and winding will experience a mechanical movement created by the electromagnetic forces. There are various types of transformer condition monitoring measurement in market, but the monitoring of the mechanical movement in transformer is still lacking. Therefore, Sweep Frequency Response Analysis (SFRA) has been introduced to assess any mechanical movement especially of the transformer's core and winding. The frequency response of the transformer provides mechanical information of core and winding conditions. The SFRA measurement results were validated using the actual transformer untanking process. � 2013 The Authors. Published by Elsevier. |
author2 |
56504019900 |
author_facet |
56504019900 Ghani S.A. Thayoob Y.H.M. Ghazali Y.Z.Y. Khiar M.S.A. Chairul I.S. |
format |
Conference Paper |
author |
Ghani S.A. Thayoob Y.H.M. Ghazali Y.Z.Y. Khiar M.S.A. Chairul I.S. |
author_sort |
Ghani S.A. |
title |
Condition monitoring of distribution transformer's mechanical parts using sweep frequency response analysis (SFRA) |
title_short |
Condition monitoring of distribution transformer's mechanical parts using sweep frequency response analysis (SFRA) |
title_full |
Condition monitoring of distribution transformer's mechanical parts using sweep frequency response analysis (SFRA) |
title_fullStr |
Condition monitoring of distribution transformer's mechanical parts using sweep frequency response analysis (SFRA) |
title_full_unstemmed |
Condition monitoring of distribution transformer's mechanical parts using sweep frequency response analysis (SFRA) |
title_sort |
condition monitoring of distribution transformer's mechanical parts using sweep frequency response analysis (sfra) |
publisher |
Elsevier Ltd |
publishDate |
2023 |
_version_ |
1806426046847778816 |