PQ monitor-based automated fault location using database technique for 11kV distribution system

Various fault locating techniques have been thoroughly discussed throughout the decades. Many of the techniques prior to this require many monitors and also relay operation information to accurately locate the fault. The latest fault locating approach utilizes power quality (PQ) monitors, which are...

Full description

Saved in:
Bibliographic Details
Main Authors: Tan C.K., Ramachandaramurthy V.K.
Other Authors: 55921560400
Format: Article
Published: Praise Worthy Prize S.r.l 2023
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Tenaga Nasional
id my.uniten.dspace-30455
record_format dspace
spelling my.uniten.dspace-304552023-12-29T15:48:02Z PQ monitor-based automated fault location using database technique for 11kV distribution system Tan C.K. Ramachandaramurthy V.K. 55921560400 6602912020 Database method Fault location Power quality monitoring Substation predictive maintenance Various fault locating techniques have been thoroughly discussed throughout the decades. Many of the techniques prior to this require many monitors and also relay operation information to accurately locate the fault. The latest fault locating approach utilizes power quality (PQ) monitors, which are faster and able to detect any short duration events. Majority of the fault locating techniques however focuses on locating downstream faults only. This paper proposes a novel technique to locate faults in several neighboring substations utilizing only one PQ monitor, thus breaking the boundaries of conventional downstream fault locating techniques. Besides locating faults in neighboring substations, this technique also allows the type of fault to be identified. The algorithm uses Three-Dimension (3D) Voltage Vector Database Matching method to accomplish this task. The algorithm proposed in this paper can accurately point to the fault location. Successful identification of fault location using this proposed technique will allow engineers to identify incipient faults in the substation. This will certainly revolutionize the way engineers plan and execute their substation maintenance strategy. � 2011 Praise Worthy Prize S.r.l. - All rights reserved. Final 2023-12-29T07:48:02Z 2023-12-29T07:48:02Z 2011 Article 2-s2.0-82455175922 https://www.scopus.com/inward/record.uri?eid=2-s2.0-82455175922&partnerID=40&md5=d95c3c836cac279bd1fb56a05f4fec70 https://irepository.uniten.edu.my/handle/123456789/30455 6 2 946 952 Praise Worthy Prize S.r.l Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
topic Database method
Fault location
Power quality monitoring
Substation predictive maintenance
spellingShingle Database method
Fault location
Power quality monitoring
Substation predictive maintenance
Tan C.K.
Ramachandaramurthy V.K.
PQ monitor-based automated fault location using database technique for 11kV distribution system
description Various fault locating techniques have been thoroughly discussed throughout the decades. Many of the techniques prior to this require many monitors and also relay operation information to accurately locate the fault. The latest fault locating approach utilizes power quality (PQ) monitors, which are faster and able to detect any short duration events. Majority of the fault locating techniques however focuses on locating downstream faults only. This paper proposes a novel technique to locate faults in several neighboring substations utilizing only one PQ monitor, thus breaking the boundaries of conventional downstream fault locating techniques. Besides locating faults in neighboring substations, this technique also allows the type of fault to be identified. The algorithm uses Three-Dimension (3D) Voltage Vector Database Matching method to accomplish this task. The algorithm proposed in this paper can accurately point to the fault location. Successful identification of fault location using this proposed technique will allow engineers to identify incipient faults in the substation. This will certainly revolutionize the way engineers plan and execute their substation maintenance strategy. � 2011 Praise Worthy Prize S.r.l. - All rights reserved.
author2 55921560400
author_facet 55921560400
Tan C.K.
Ramachandaramurthy V.K.
format Article
author Tan C.K.
Ramachandaramurthy V.K.
author_sort Tan C.K.
title PQ monitor-based automated fault location using database technique for 11kV distribution system
title_short PQ monitor-based automated fault location using database technique for 11kV distribution system
title_full PQ monitor-based automated fault location using database technique for 11kV distribution system
title_fullStr PQ monitor-based automated fault location using database technique for 11kV distribution system
title_full_unstemmed PQ monitor-based automated fault location using database technique for 11kV distribution system
title_sort pq monitor-based automated fault location using database technique for 11kv distribution system
publisher Praise Worthy Prize S.r.l
publishDate 2023
_version_ 1806428012331139072