Cross phase polarization algorithm for fault direction determination using zero crossing method to determine phase difference

Power systems are usually connected in a condition where there is more than one power supply or voltage source supplying a load. These systems will have protection relays to protect various equipment connected to the system. However in isolating a fault, the direction of the fault needs to be known...

Full description

Saved in:
Bibliographic Details
Main Authors: Abidin A.A.B.Z., Ramasamy A., Abidin I.Z., Nagi F.H.
Other Authors: 25824750400
Format: Conference paper
Published: 2023
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Tenaga Nasional
id my.uniten.dspace-30741
record_format dspace
spelling my.uniten.dspace-307412023-12-29T15:52:16Z Cross phase polarization algorithm for fault direction determination using zero crossing method to determine phase difference Abidin A.A.B.Z. Ramasamy A. Abidin I.Z. Nagi F.H. 25824750400 16023154400 35606640500 56272534200 Cross phase polarization Ground fault Multi sourced power system Phase difference Phase to phase fault Electric grounding MATLAB Phase comparators Sustainable development Underground cables Ground faults Phase difference Phase to phase fault Phase to phase faults Power systems Polarization Power systems are usually connected in a condition where there is more than one power supply or voltage source supplying a load. These systems will have protection relays to protect various equipment connected to the system. However in isolating a fault, the direction of the fault needs to be known in order to limit the amount of loss load. This paper shall describe a possible algorithm that could be used in order to perform cross phase polarization. The possible faults that could be detected using this technique include the single phase to ground fault, the phase to phase fault and the double phase to ground fault. Three phase faults require the memory polarization technique that will not be discussed in this paper. The algorithm shall be implemented and tested using the sim power system tool box present in MATLAB. �2009 IEEE. Final 2023-12-29T07:52:16Z 2023-12-29T07:52:16Z 2009 Conference paper 10.1109/ICEENVIRON.2009.5398619 2-s2.0-77949610847 https://www.scopus.com/inward/record.uri?eid=2-s2.0-77949610847&doi=10.1109%2fICEENVIRON.2009.5398619&partnerID=40&md5=5efbe68a6a156e92ce607f6019d5b7a8 https://irepository.uniten.edu.my/handle/123456789/30741 5398619 369 373 Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
topic Cross phase polarization
Ground fault
Multi sourced power system
Phase difference
Phase to phase fault
Electric grounding
MATLAB
Phase comparators
Sustainable development
Underground cables
Ground faults
Phase difference
Phase to phase fault
Phase to phase faults
Power systems
Polarization
spellingShingle Cross phase polarization
Ground fault
Multi sourced power system
Phase difference
Phase to phase fault
Electric grounding
MATLAB
Phase comparators
Sustainable development
Underground cables
Ground faults
Phase difference
Phase to phase fault
Phase to phase faults
Power systems
Polarization
Abidin A.A.B.Z.
Ramasamy A.
Abidin I.Z.
Nagi F.H.
Cross phase polarization algorithm for fault direction determination using zero crossing method to determine phase difference
description Power systems are usually connected in a condition where there is more than one power supply or voltage source supplying a load. These systems will have protection relays to protect various equipment connected to the system. However in isolating a fault, the direction of the fault needs to be known in order to limit the amount of loss load. This paper shall describe a possible algorithm that could be used in order to perform cross phase polarization. The possible faults that could be detected using this technique include the single phase to ground fault, the phase to phase fault and the double phase to ground fault. Three phase faults require the memory polarization technique that will not be discussed in this paper. The algorithm shall be implemented and tested using the sim power system tool box present in MATLAB. �2009 IEEE.
author2 25824750400
author_facet 25824750400
Abidin A.A.B.Z.
Ramasamy A.
Abidin I.Z.
Nagi F.H.
format Conference paper
author Abidin A.A.B.Z.
Ramasamy A.
Abidin I.Z.
Nagi F.H.
author_sort Abidin A.A.B.Z.
title Cross phase polarization algorithm for fault direction determination using zero crossing method to determine phase difference
title_short Cross phase polarization algorithm for fault direction determination using zero crossing method to determine phase difference
title_full Cross phase polarization algorithm for fault direction determination using zero crossing method to determine phase difference
title_fullStr Cross phase polarization algorithm for fault direction determination using zero crossing method to determine phase difference
title_full_unstemmed Cross phase polarization algorithm for fault direction determination using zero crossing method to determine phase difference
title_sort cross phase polarization algorithm for fault direction determination using zero crossing method to determine phase difference
publishDate 2023
_version_ 1806423405169213440