Cross phase polarization algorithm for fault direction determination using zero crossing method to determine phase difference
Power systems are usually connected in a condition where there is more than one power supply or voltage source supplying a load. These systems will have protection relays to protect various equipment connected to the system. However in isolating a fault, the direction of the fault needs to be known...
Saved in:
Main Authors: | , , , |
---|---|
Other Authors: | |
Format: | Conference paper |
Published: |
2023
|
Subjects: | |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Tenaga Nasional |
id |
my.uniten.dspace-30741 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-307412023-12-29T15:52:16Z Cross phase polarization algorithm for fault direction determination using zero crossing method to determine phase difference Abidin A.A.B.Z. Ramasamy A. Abidin I.Z. Nagi F.H. 25824750400 16023154400 35606640500 56272534200 Cross phase polarization Ground fault Multi sourced power system Phase difference Phase to phase fault Electric grounding MATLAB Phase comparators Sustainable development Underground cables Ground faults Phase difference Phase to phase fault Phase to phase faults Power systems Polarization Power systems are usually connected in a condition where there is more than one power supply or voltage source supplying a load. These systems will have protection relays to protect various equipment connected to the system. However in isolating a fault, the direction of the fault needs to be known in order to limit the amount of loss load. This paper shall describe a possible algorithm that could be used in order to perform cross phase polarization. The possible faults that could be detected using this technique include the single phase to ground fault, the phase to phase fault and the double phase to ground fault. Three phase faults require the memory polarization technique that will not be discussed in this paper. The algorithm shall be implemented and tested using the sim power system tool box present in MATLAB. �2009 IEEE. Final 2023-12-29T07:52:16Z 2023-12-29T07:52:16Z 2009 Conference paper 10.1109/ICEENVIRON.2009.5398619 2-s2.0-77949610847 https://www.scopus.com/inward/record.uri?eid=2-s2.0-77949610847&doi=10.1109%2fICEENVIRON.2009.5398619&partnerID=40&md5=5efbe68a6a156e92ce607f6019d5b7a8 https://irepository.uniten.edu.my/handle/123456789/30741 5398619 369 373 Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
topic |
Cross phase polarization Ground fault Multi sourced power system Phase difference Phase to phase fault Electric grounding MATLAB Phase comparators Sustainable development Underground cables Ground faults Phase difference Phase to phase fault Phase to phase faults Power systems Polarization |
spellingShingle |
Cross phase polarization Ground fault Multi sourced power system Phase difference Phase to phase fault Electric grounding MATLAB Phase comparators Sustainable development Underground cables Ground faults Phase difference Phase to phase fault Phase to phase faults Power systems Polarization Abidin A.A.B.Z. Ramasamy A. Abidin I.Z. Nagi F.H. Cross phase polarization algorithm for fault direction determination using zero crossing method to determine phase difference |
description |
Power systems are usually connected in a condition where there is more than one power supply or voltage source supplying a load. These systems will have protection relays to protect various equipment connected to the system. However in isolating a fault, the direction of the fault needs to be known in order to limit the amount of loss load. This paper shall describe a possible algorithm that could be used in order to perform cross phase polarization. The possible faults that could be detected using this technique include the single phase to ground fault, the phase to phase fault and the double phase to ground fault. Three phase faults require the memory polarization technique that will not be discussed in this paper. The algorithm shall be implemented and tested using the sim power system tool box present in MATLAB. �2009 IEEE. |
author2 |
25824750400 |
author_facet |
25824750400 Abidin A.A.B.Z. Ramasamy A. Abidin I.Z. Nagi F.H. |
format |
Conference paper |
author |
Abidin A.A.B.Z. Ramasamy A. Abidin I.Z. Nagi F.H. |
author_sort |
Abidin A.A.B.Z. |
title |
Cross phase polarization algorithm for fault direction determination using zero crossing method to determine phase difference |
title_short |
Cross phase polarization algorithm for fault direction determination using zero crossing method to determine phase difference |
title_full |
Cross phase polarization algorithm for fault direction determination using zero crossing method to determine phase difference |
title_fullStr |
Cross phase polarization algorithm for fault direction determination using zero crossing method to determine phase difference |
title_full_unstemmed |
Cross phase polarization algorithm for fault direction determination using zero crossing method to determine phase difference |
title_sort |
cross phase polarization algorithm for fault direction determination using zero crossing method to determine phase difference |
publishDate |
2023 |
_version_ |
1806423405169213440 |