The Mechanical Designing Process of Proposed Ventilation System For Home Environments
The research began with general idea to look regards to ventilation system performance in Malaysia. Ventilation is the mechanical system in a building that acquires 'new' open air and evacuates the 'defiled' indoor air. Ventilation system utilized to control disclosure to airborn...
Saved in:
Main Authors: | , , , |
---|---|
Other Authors: | |
Format: | Conference Paper |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2024
|
Subjects: | |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Tenaga Nasional |
id |
my.uniten.dspace-34355 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-343552024-10-14T11:19:15Z The Mechanical Designing Process of Proposed Ventilation System For Home Environments Syaifoelida F. Kumar S.U. Jati E. Hamdan A.M.M. 57191924036 59252739900 59252740000 59252093300 home environments ventilation system Product design Room temperature Ventilation Airborne contaminants Designing process Home environment Indoor air Malaysia Mechanical designing Mechanical systems Morphological diagrams Systems performance Ventilation systems Conceptual design The research began with general idea to look regards to ventilation system performance in Malaysia. Ventilation is the mechanical system in a building that acquires 'new' open air and evacuates the 'defiled' indoor air. Ventilation system utilized to control disclosure to airborne contaminants. It is usually use to evacuate contaminants, for example, exhaust, cleans, and vapours. There are fundamental factors that need to be considered. The customer criteria were collected in Klang Valley through survey and interview. The conceptual design was selected by using morphological diagram and was translated to SOLIDWORK. There are four conceptual designs were generated. The confirmation result was gained by using Ansys, to stimulate, to run and able to verify that this product design will run automatically when the enclosed room temperature at 27�C to 30�C. Objective to reduce the waste of electricity and maintain the enclosed room temperature. � 2023 IEEE. Final 2024-10-14T03:19:15Z 2024-10-14T03:19:15Z 2023 Conference Paper 10.1109/RAAI59955.2023.10601258 2-s2.0-85200731155 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85200731155&doi=10.1109%2fRAAI59955.2023.10601258&partnerID=40&md5=5b6d62b4d359952d13dbfd342eb2be4b https://irepository.uniten.edu.my/handle/123456789/34355 70 74 Institute of Electrical and Electronics Engineers Inc. Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
topic |
home environments ventilation system Product design Room temperature Ventilation Airborne contaminants Designing process Home environment Indoor air Malaysia Mechanical designing Mechanical systems Morphological diagrams Systems performance Ventilation systems Conceptual design |
spellingShingle |
home environments ventilation system Product design Room temperature Ventilation Airborne contaminants Designing process Home environment Indoor air Malaysia Mechanical designing Mechanical systems Morphological diagrams Systems performance Ventilation systems Conceptual design Syaifoelida F. Kumar S.U. Jati E. Hamdan A.M.M. The Mechanical Designing Process of Proposed Ventilation System For Home Environments |
description |
The research began with general idea to look regards to ventilation system performance in Malaysia. Ventilation is the mechanical system in a building that acquires 'new' open air and evacuates the 'defiled' indoor air. Ventilation system utilized to control disclosure to airborne contaminants. It is usually use to evacuate contaminants, for example, exhaust, cleans, and vapours. There are fundamental factors that need to be considered. The customer criteria were collected in Klang Valley through survey and interview. The conceptual design was selected by using morphological diagram and was translated to SOLIDWORK. There are four conceptual designs were generated. The confirmation result was gained by using Ansys, to stimulate, to run and able to verify that this product design will run automatically when the enclosed room temperature at 27�C to 30�C. Objective to reduce the waste of electricity and maintain the enclosed room temperature. � 2023 IEEE. |
author2 |
57191924036 |
author_facet |
57191924036 Syaifoelida F. Kumar S.U. Jati E. Hamdan A.M.M. |
format |
Conference Paper |
author |
Syaifoelida F. Kumar S.U. Jati E. Hamdan A.M.M. |
author_sort |
Syaifoelida F. |
title |
The Mechanical Designing Process of Proposed Ventilation System For Home Environments |
title_short |
The Mechanical Designing Process of Proposed Ventilation System For Home Environments |
title_full |
The Mechanical Designing Process of Proposed Ventilation System For Home Environments |
title_fullStr |
The Mechanical Designing Process of Proposed Ventilation System For Home Environments |
title_full_unstemmed |
The Mechanical Designing Process of Proposed Ventilation System For Home Environments |
title_sort |
mechanical designing process of proposed ventilation system for home environments |
publisher |
Institute of Electrical and Electronics Engineers Inc. |
publishDate |
2024 |
_version_ |
1814061051940962304 |