Dissipation factor measurement of PILC insulation at UHF
In this paper, dissipation factor measurement of Paper Insulated Lead Covered (PILC) cable insulation at ultra high frequency (UHF) is described. The material under test (MUT) is clamped between two copper sheets to form a capacitor, which is connected to the Advantest R3767CG vector network analyze...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Conference Paper |
Language: | en_US |
Published: |
2017
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Tenaga Nasional |
Language: | en_US |
id |
my.uniten.dspace-5709 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-57092017-12-15T00:41:36Z Dissipation factor measurement of PILC insulation at UHF Raymond, W.J.K. Chakrabarty, C.K. Hock, G.C. Ghani, A.B. Zarim, Z.A.A. In this paper, dissipation factor measurement of Paper Insulated Lead Covered (PILC) cable insulation at ultra high frequency (UHF) is described. The material under test (MUT) is clamped between two copper sheets to form a capacitor, which is connected to the Advantest R3767CG vector network analyzer (VNA) to measure its input impedance at the resonant frequency. From the input impedance, the dissipation factor is calculated. The calculated values are then compared with data obtained from commercial system to validate the proposed method. © 2012 IEEE. 2017-12-08T06:45:35Z 2017-12-08T06:45:35Z 2012 Conference Paper 10.1109/ISMS.2012.55 en_US Proceedings - 3rd International Conference on Intelligent Systems Modelling and Simulation, ISMS 2012 2012, Article number 6169692, Pages 157-160 |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
language |
en_US |
description |
In this paper, dissipation factor measurement of Paper Insulated Lead Covered (PILC) cable insulation at ultra high frequency (UHF) is described. The material under test (MUT) is clamped between two copper sheets to form a capacitor, which is connected to the Advantest R3767CG vector network analyzer (VNA) to measure its input impedance at the resonant frequency. From the input impedance, the dissipation factor is calculated. The calculated values are then compared with data obtained from commercial system to validate the proposed method. © 2012 IEEE. |
format |
Conference Paper |
author |
Raymond, W.J.K. Chakrabarty, C.K. Hock, G.C. Ghani, A.B. Zarim, Z.A.A. |
spellingShingle |
Raymond, W.J.K. Chakrabarty, C.K. Hock, G.C. Ghani, A.B. Zarim, Z.A.A. Dissipation factor measurement of PILC insulation at UHF |
author_facet |
Raymond, W.J.K. Chakrabarty, C.K. Hock, G.C. Ghani, A.B. Zarim, Z.A.A. |
author_sort |
Raymond, W.J.K. |
title |
Dissipation factor measurement of PILC insulation at UHF |
title_short |
Dissipation factor measurement of PILC insulation at UHF |
title_full |
Dissipation factor measurement of PILC insulation at UHF |
title_fullStr |
Dissipation factor measurement of PILC insulation at UHF |
title_full_unstemmed |
Dissipation factor measurement of PILC insulation at UHF |
title_sort |
dissipation factor measurement of pilc insulation at uhf |
publishDate |
2017 |
_version_ |
1644493755164655616 |