The detection of magnetic field from Partial Discharge (PD) signal in XLPE cable using inductive probe

Partial discharge is a well known phenomenon that caused insulation degradation in cross-linked polyethylene power cable. Thus eventually will cause insulation failure. When partial discharge occurs, it radiates electromagnetic field in all direction. This electromagnetic field has a bandwidth of ab...

Full description

Saved in:
Bibliographic Details
Main Authors: Ghani, A.B.A., Chakrabarty, C.K.
Format: Conference Paper
Language:en_US
Published: 2017
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Tenaga Nasional
Language: en_US
id my.uniten.dspace-5735
record_format dspace
spelling my.uniten.dspace-57352017-12-14T02:40:09Z The detection of magnetic field from Partial Discharge (PD) signal in XLPE cable using inductive probe Ghani, A.B.A. Chakrabarty, C.K. Partial discharge is a well known phenomenon that caused insulation degradation in cross-linked polyethylene power cable. Thus eventually will cause insulation failure. When partial discharge occurs, it radiates electromagnetic field in all direction. This electromagnetic field has a bandwidth of about 1GHz at source. This paper hence describes the design of a simple single layer air-core coil as inductive probe to detect the presence of magnetic field components due to partial discharge. It is shown that, it is possible to detect the presence of PD at 1m away from the cable. 2017-12-08T06:45:46Z 2017-12-08T06:45:46Z 2008 Conference Paper 10.1109/ISEIM.2008.4664581 en_US Proceedings of the International Symposium on Electrical Insulating Materials 2008, Article number 4664581, Pages 444-447
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
language en_US
description Partial discharge is a well known phenomenon that caused insulation degradation in cross-linked polyethylene power cable. Thus eventually will cause insulation failure. When partial discharge occurs, it radiates electromagnetic field in all direction. This electromagnetic field has a bandwidth of about 1GHz at source. This paper hence describes the design of a simple single layer air-core coil as inductive probe to detect the presence of magnetic field components due to partial discharge. It is shown that, it is possible to detect the presence of PD at 1m away from the cable.
format Conference Paper
author Ghani, A.B.A.
Chakrabarty, C.K.
spellingShingle Ghani, A.B.A.
Chakrabarty, C.K.
The detection of magnetic field from Partial Discharge (PD) signal in XLPE cable using inductive probe
author_facet Ghani, A.B.A.
Chakrabarty, C.K.
author_sort Ghani, A.B.A.
title The detection of magnetic field from Partial Discharge (PD) signal in XLPE cable using inductive probe
title_short The detection of magnetic field from Partial Discharge (PD) signal in XLPE cable using inductive probe
title_full The detection of magnetic field from Partial Discharge (PD) signal in XLPE cable using inductive probe
title_fullStr The detection of magnetic field from Partial Discharge (PD) signal in XLPE cable using inductive probe
title_full_unstemmed The detection of magnetic field from Partial Discharge (PD) signal in XLPE cable using inductive probe
title_sort detection of magnetic field from partial discharge (pd) signal in xlpe cable using inductive probe
publishDate 2017
_version_ 1644493762118811648