Enhanced electrochemical detection of iodide at a reduced graphene oxide-modified carbon electrode in iodized salts

In this study, enhancement of electrochemical performance of electrochemically reduced graphene oxide (ERGO) on a screen-printed carbon electrode (SPCE) (ERGO/SPCE) coupled with ion-pairing (cetyltrimethylammonium bromide, CTAB) for the determination of iodide in table salt has been described. The e...

Full description

Saved in:
Bibliographic Details
Main Authors: Jamilan, Mohd Azerulazree, Abdullah, Jaafar, Alang Ahmad, Shahrul Ainliah, Md Noh, Mohd Fairulnizal
Format: Article
Published: Elsevier 2022
Online Access:http://psasir.upm.edu.my/id/eprint/101262/
https://www.sciencedirect.com/science/article/pii/S0308814622013449
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
id my.upm.eprints.101262
record_format eprints
spelling my.upm.eprints.1012622023-08-15T04:22:23Z http://psasir.upm.edu.my/id/eprint/101262/ Enhanced electrochemical detection of iodide at a reduced graphene oxide-modified carbon electrode in iodized salts Jamilan, Mohd Azerulazree Abdullah, Jaafar Alang Ahmad, Shahrul Ainliah Md Noh, Mohd Fairulnizal In this study, enhancement of electrochemical performance of electrochemically reduced graphene oxide (ERGO) on a screen-printed carbon electrode (SPCE) (ERGO/SPCE) coupled with ion-pairing (cetyltrimethylammonium bromide, CTAB) for the determination of iodide in table salt has been described. The electrode modification of ERGO/SPCE was conducted using cyclic voltammetric (CV) scanning in the potential range of 1.3–0.4 V for 50 cycles after the drop-casting of graphene oxide (GO) suspension on the SPCE. It was found that the electro-active surface area of ERGO/SPCE was increased by 1.5-fold compared to the bare SPCE. ERGO/SPCE sensor displays linearity towards iodide in the concentration range from 0.020 to 1.0 mg/L (sensitivity = 5.40 µA(mg/L)−1, R2 = 0.9906) with the limit of detection (LOD) and limit of quantitation (LOQ) of 0.070 mg/L and 0.21 mg/L, respectively. The comparison between polarography and ERGO/SPCE sensor was in good agreement. Elsevier 2022 Article PeerReviewed Jamilan, Mohd Azerulazree and Abdullah, Jaafar and Alang Ahmad, Shahrul Ainliah and Md Noh, Mohd Fairulnizal (2022) Enhanced electrochemical detection of iodide at a reduced graphene oxide-modified carbon electrode in iodized salts. Food Chemistry, 393. art. no. 133382. pp. 1-8. ISSN 0308-8146; ESSN: 1873-7072 https://www.sciencedirect.com/science/article/pii/S0308814622013449 10.1016/j.foodchem.2022.133382
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
description In this study, enhancement of electrochemical performance of electrochemically reduced graphene oxide (ERGO) on a screen-printed carbon electrode (SPCE) (ERGO/SPCE) coupled with ion-pairing (cetyltrimethylammonium bromide, CTAB) for the determination of iodide in table salt has been described. The electrode modification of ERGO/SPCE was conducted using cyclic voltammetric (CV) scanning in the potential range of 1.3–0.4 V for 50 cycles after the drop-casting of graphene oxide (GO) suspension on the SPCE. It was found that the electro-active surface area of ERGO/SPCE was increased by 1.5-fold compared to the bare SPCE. ERGO/SPCE sensor displays linearity towards iodide in the concentration range from 0.020 to 1.0 mg/L (sensitivity = 5.40 µA(mg/L)−1, R2 = 0.9906) with the limit of detection (LOD) and limit of quantitation (LOQ) of 0.070 mg/L and 0.21 mg/L, respectively. The comparison between polarography and ERGO/SPCE sensor was in good agreement.
format Article
author Jamilan, Mohd Azerulazree
Abdullah, Jaafar
Alang Ahmad, Shahrul Ainliah
Md Noh, Mohd Fairulnizal
spellingShingle Jamilan, Mohd Azerulazree
Abdullah, Jaafar
Alang Ahmad, Shahrul Ainliah
Md Noh, Mohd Fairulnizal
Enhanced electrochemical detection of iodide at a reduced graphene oxide-modified carbon electrode in iodized salts
author_facet Jamilan, Mohd Azerulazree
Abdullah, Jaafar
Alang Ahmad, Shahrul Ainliah
Md Noh, Mohd Fairulnizal
author_sort Jamilan, Mohd Azerulazree
title Enhanced electrochemical detection of iodide at a reduced graphene oxide-modified carbon electrode in iodized salts
title_short Enhanced electrochemical detection of iodide at a reduced graphene oxide-modified carbon electrode in iodized salts
title_full Enhanced electrochemical detection of iodide at a reduced graphene oxide-modified carbon electrode in iodized salts
title_fullStr Enhanced electrochemical detection of iodide at a reduced graphene oxide-modified carbon electrode in iodized salts
title_full_unstemmed Enhanced electrochemical detection of iodide at a reduced graphene oxide-modified carbon electrode in iodized salts
title_sort enhanced electrochemical detection of iodide at a reduced graphene oxide-modified carbon electrode in iodized salts
publisher Elsevier
publishDate 2022
url http://psasir.upm.edu.my/id/eprint/101262/
https://www.sciencedirect.com/science/article/pii/S0308814622013449
_version_ 1775624491103158272