The impact of tube current and iterative reconstruction algorithm on dose and image quality of infant CT head examination

Computed Tomography (CT) scan examination has been recognized for its potential in contributing high radiation doses, which raised a public concern towards pediatric exposure, especially infants. Thus, the optimization is vital through well-balanced levels of radiation and image quality. Hence, this...

Full description

Saved in:
Bibliographic Details
Main Authors: Muhammad, N.A., Karim, M.K.A., Harun, H.H., Rahman, M.A.A., Azlan, R.N.R.M., Sumardi, N.F.
Format: Article
Published: Elsevier 2022
Online Access:http://psasir.upm.edu.my/id/eprint/103590/
https://www.sciencedirect.com/science/article/pii/S0969806X22003140
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
id my.upm.eprints.103590
record_format eprints
spelling my.upm.eprints.1035902023-10-25T02:33:16Z http://psasir.upm.edu.my/id/eprint/103590/ The impact of tube current and iterative reconstruction algorithm on dose and image quality of infant CT head examination Muhammad, N.A. Karim, M.K.A. Harun, H.H. Rahman, M.A.A. Azlan, R.N.R.M. Sumardi, N.F. Computed Tomography (CT) scan examination has been recognized for its potential in contributing high radiation doses, which raised a public concern towards pediatric exposure, especially infants. Thus, the optimization is vital through well-balanced levels of radiation and image quality. Hence, this study aimed to investigate optimized CT acquisition parameter on radiosensitive organs of infant CT head examination and its influence on the image quality. This study utilized a 1-year-old anthropomorphic phantom and thermoluminescence dosimeter (TLD) for organ dose assessment. The examination was performed by using 128 multi-slice CT (Ingenuity Core, Philips, Netherlands) and varying the tube current and iterative reconstruction algorithm (iDose4) levels. During the process, the reference mAs (ref. mAs) were altered while maintaining the tube potential at 100 kVp. Five protocols were established and denoted by P1, P2, P3, P4, and P5. As per measurement, 3 calibrated TLD chips were implanted into the phantom on slab numbers 2, 4, and 7 that represented brain, lens, and thyroid, respectively. Image quality was evaluated by utilizing the objective assessment in terms of signal to noise ratio (SNR) and contrast to noise ratio (CNR) and subjective image quality using the Visual Grading Analysis (VGA) technique in terms of sharpness, noise, and artefact were assessed from each protocol. Notably, the dose was decreased up to 30% along with the reduction of tube current and the improvement of SNR and CNR values for parameters that enable the iterative reconstruction algorithm. Hence, optimization of CT acquisition parameter should be evaluated and monitored accordingly. Elsevier 2022 Article PeerReviewed Muhammad, N.A. and Karim, M.K.A. and Harun, H.H. and Rahman, M.A.A. and Azlan, R.N.R.M. and Sumardi, N.F. (2022) The impact of tube current and iterative reconstruction algorithm on dose and image quality of infant CT head examination. Radiation Physics and Chemistry, 200. art. no. 110272. pp. 1-7. ISSN 0969-806X https://www.sciencedirect.com/science/article/pii/S0969806X22003140 10.1016/j.radphyschem.2022.110272
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
description Computed Tomography (CT) scan examination has been recognized for its potential in contributing high radiation doses, which raised a public concern towards pediatric exposure, especially infants. Thus, the optimization is vital through well-balanced levels of radiation and image quality. Hence, this study aimed to investigate optimized CT acquisition parameter on radiosensitive organs of infant CT head examination and its influence on the image quality. This study utilized a 1-year-old anthropomorphic phantom and thermoluminescence dosimeter (TLD) for organ dose assessment. The examination was performed by using 128 multi-slice CT (Ingenuity Core, Philips, Netherlands) and varying the tube current and iterative reconstruction algorithm (iDose4) levels. During the process, the reference mAs (ref. mAs) were altered while maintaining the tube potential at 100 kVp. Five protocols were established and denoted by P1, P2, P3, P4, and P5. As per measurement, 3 calibrated TLD chips were implanted into the phantom on slab numbers 2, 4, and 7 that represented brain, lens, and thyroid, respectively. Image quality was evaluated by utilizing the objective assessment in terms of signal to noise ratio (SNR) and contrast to noise ratio (CNR) and subjective image quality using the Visual Grading Analysis (VGA) technique in terms of sharpness, noise, and artefact were assessed from each protocol. Notably, the dose was decreased up to 30% along with the reduction of tube current and the improvement of SNR and CNR values for parameters that enable the iterative reconstruction algorithm. Hence, optimization of CT acquisition parameter should be evaluated and monitored accordingly.
format Article
author Muhammad, N.A.
Karim, M.K.A.
Harun, H.H.
Rahman, M.A.A.
Azlan, R.N.R.M.
Sumardi, N.F.
spellingShingle Muhammad, N.A.
Karim, M.K.A.
Harun, H.H.
Rahman, M.A.A.
Azlan, R.N.R.M.
Sumardi, N.F.
The impact of tube current and iterative reconstruction algorithm on dose and image quality of infant CT head examination
author_facet Muhammad, N.A.
Karim, M.K.A.
Harun, H.H.
Rahman, M.A.A.
Azlan, R.N.R.M.
Sumardi, N.F.
author_sort Muhammad, N.A.
title The impact of tube current and iterative reconstruction algorithm on dose and image quality of infant CT head examination
title_short The impact of tube current and iterative reconstruction algorithm on dose and image quality of infant CT head examination
title_full The impact of tube current and iterative reconstruction algorithm on dose and image quality of infant CT head examination
title_fullStr The impact of tube current and iterative reconstruction algorithm on dose and image quality of infant CT head examination
title_full_unstemmed The impact of tube current and iterative reconstruction algorithm on dose and image quality of infant CT head examination
title_sort impact of tube current and iterative reconstruction algorithm on dose and image quality of infant ct head examination
publisher Elsevier
publishDate 2022
url http://psasir.upm.edu.my/id/eprint/103590/
https://www.sciencedirect.com/science/article/pii/S0969806X22003140
_version_ 1781706720033112064