Design of Single-Phase Active Power Filter for Harmonic Mitigation in Distribution Power Line

Recently, the wide use of power electronic components in various application s has affected the quality of the power. One of the most serious problems is that of the harmonic, which is generated from the nonlinear loads such as variable frequency AC motor drives, uninterruptible power supplies (U...

Full description

Saved in:
Bibliographic Details
Main Author: Dahidah, Mohamed S. A.
Format: Thesis
Language:English
English
Published: 2002
Subjects:
Online Access:http://psasir.upm.edu.my/id/eprint/10470/1/FK_2002_2.pdf
http://psasir.upm.edu.my/id/eprint/10470/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
Language: English
English
id my.upm.eprints.10470
record_format eprints
spelling my.upm.eprints.104702024-03-29T08:04:38Z http://psasir.upm.edu.my/id/eprint/10470/ Design of Single-Phase Active Power Filter for Harmonic Mitigation in Distribution Power Line Dahidah, Mohamed S. A. Recently, the wide use of power electronic components in various application s has affected the quality of the power. One of the most serious problems is that of the harmonic, which is generated from the nonlinear loads such as variable frequency AC motor drives, uninterruptible power supplies (UPSs), personal computers, laser printers, and many more [1-4], is has harmful effect on the electrical equipment. Several techniques have been carried out over the year to prevent the effects of the harmonic [3], [7], The active power filter is the most efficient method, which has been developed in different configuration s to meet the different demands [9]. This thesis presents the design and development of a single-phase shunt active power filter that is suitable for commercial or education al buildings with computer loads [9]. The proposed filter is designed to mitigate the third and fifth order harmonics for two main reasons. Firstly, because of using large number of relatively small single phase loads that may produce excessive total amount of the third harmonic fifth and seventh harmonic [3]. Secondly because of the active power filter rating could be highly reduced when the suppression of one or two special harmonics is effected by the active filter [20]. 2002-01 Thesis NonPeerReviewed text en http://psasir.upm.edu.my/id/eprint/10470/1/FK_2002_2.pdf Dahidah, Mohamed S. A. (2002) Design of Single-Phase Active Power Filter for Harmonic Mitigation in Distribution Power Line. Masters thesis, Universiti Putra Malaysia. Power electronics Harmonic analyzers English
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
English
topic Power electronics
Harmonic analyzers
spellingShingle Power electronics
Harmonic analyzers
Dahidah, Mohamed S. A.
Design of Single-Phase Active Power Filter for Harmonic Mitigation in Distribution Power Line
description Recently, the wide use of power electronic components in various application s has affected the quality of the power. One of the most serious problems is that of the harmonic, which is generated from the nonlinear loads such as variable frequency AC motor drives, uninterruptible power supplies (UPSs), personal computers, laser printers, and many more [1-4], is has harmful effect on the electrical equipment. Several techniques have been carried out over the year to prevent the effects of the harmonic [3], [7], The active power filter is the most efficient method, which has been developed in different configuration s to meet the different demands [9]. This thesis presents the design and development of a single-phase shunt active power filter that is suitable for commercial or education al buildings with computer loads [9]. The proposed filter is designed to mitigate the third and fifth order harmonics for two main reasons. Firstly, because of using large number of relatively small single phase loads that may produce excessive total amount of the third harmonic fifth and seventh harmonic [3]. Secondly because of the active power filter rating could be highly reduced when the suppression of one or two special harmonics is effected by the active filter [20].
format Thesis
author Dahidah, Mohamed S. A.
author_facet Dahidah, Mohamed S. A.
author_sort Dahidah, Mohamed S. A.
title Design of Single-Phase Active Power Filter for Harmonic Mitigation in Distribution Power Line
title_short Design of Single-Phase Active Power Filter for Harmonic Mitigation in Distribution Power Line
title_full Design of Single-Phase Active Power Filter for Harmonic Mitigation in Distribution Power Line
title_fullStr Design of Single-Phase Active Power Filter for Harmonic Mitigation in Distribution Power Line
title_full_unstemmed Design of Single-Phase Active Power Filter for Harmonic Mitigation in Distribution Power Line
title_sort design of single-phase active power filter for harmonic mitigation in distribution power line
publishDate 2002
url http://psasir.upm.edu.my/id/eprint/10470/1/FK_2002_2.pdf
http://psasir.upm.edu.my/id/eprint/10470/
_version_ 1797910822309068800