Dose map blood irradiator dosimetry system: customized blood equivalent phantom and gafchromic EBT-XD film

Blood irradiation is done to sterilize and cease donor T-lymphocytes functionality to avoid Transfusion Associated-Graft Versus Host Disease (TA-GVHD). Dose mapping is the primary means of ensuring that the irradiation process is being conducted correctly. The aim of this study is to measure the min...

Full description

Saved in:
Bibliographic Details
Main Authors: Saiful Fazad, Adiela, Nasir, Muhammad Amir, Noor, Noramaliza Mohd Noor
Format: Article
Language:English
Published: Longe Medikal 2023
Online Access:http://psasir.upm.edu.my/id/eprint/107405/1/107405.pdf
http://psasir.upm.edu.my/id/eprint/107405/
https://ajmedtech.com/index.php/journal/article/view/48
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
Language: English
id my.upm.eprints.107405
record_format eprints
spelling my.upm.eprints.1074052024-11-04T03:06:44Z http://psasir.upm.edu.my/id/eprint/107405/ Dose map blood irradiator dosimetry system: customized blood equivalent phantom and gafchromic EBT-XD film Saiful Fazad, Adiela Nasir, Muhammad Amir Noor, Noramaliza Mohd Noor Blood irradiation is done to sterilize and cease donor T-lymphocytes functionality to avoid Transfusion Associated-Graft Versus Host Disease (TA-GVHD). Dose mapping is the primary means of ensuring that the irradiation process is being conducted correctly. The aim of this study is to measure the minimum, maximum and central absorbed gamma radiation dose delivered at the newly customized blood equivalent phantom using a Gafchromic EBT-XD film. A Gammacell 3000 Elan Blood Irradiator with Cesium-137 source was used. To obtain the dose calibration curves, the films were placed at the center of a phantom and irradiated with the dose range from 5 Gy to 35 Gy with one unirradiated film as a control. The dose calibration curve was plotted using red, green and blue channels. While, for the dose mapping measurement, the irradiation exposure of 9.03 minutes was used to deliver a central dose of 25 Gy to the film. The response of the film will be compared with the GC Dose Mapping Report 2022 which used a water equivalent medium as a phantom. For the calibration curve, the red channel of the film was utilized in this study as it had a higher signal than the other channel. The doses obtained at central, minimum and maximum using EBT-XD film with customized blood equivalent phantom were in agreement with that obtained from GC Dose Mapping Report 2022 to be within ±7.6, ±8.51 and ±9.95 respectively. We concluded that the customized blood equivalent phantom together with EBT-XD film has a potential to map the dose in blood irradiator accurately. The doses obtained from EBT-XD film were in the range of doses needed to inhibit the proliferation of the T-lymphocytes with central, minimum and maximum doses were 26.9 Gy, 17.2 Gy and 35.7 Gy respectively. Longe Medikal 2023-07-31 Article PeerReviewed text en cc_by_sa_4 http://psasir.upm.edu.my/id/eprint/107405/1/107405.pdf Saiful Fazad, Adiela and Nasir, Muhammad Amir and Noor, Noramaliza Mohd Noor (2023) Dose map blood irradiator dosimetry system: customized blood equivalent phantom and gafchromic EBT-XD film. Asian Journal of Medical Technology, 3 (2). 44 - 53. ISSN 2682-9177; ESSN: 2682-9177 https://ajmedtech.com/index.php/journal/article/view/48 10.32896/ajmedtech.v3n2.44-54
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description Blood irradiation is done to sterilize and cease donor T-lymphocytes functionality to avoid Transfusion Associated-Graft Versus Host Disease (TA-GVHD). Dose mapping is the primary means of ensuring that the irradiation process is being conducted correctly. The aim of this study is to measure the minimum, maximum and central absorbed gamma radiation dose delivered at the newly customized blood equivalent phantom using a Gafchromic EBT-XD film. A Gammacell 3000 Elan Blood Irradiator with Cesium-137 source was used. To obtain the dose calibration curves, the films were placed at the center of a phantom and irradiated with the dose range from 5 Gy to 35 Gy with one unirradiated film as a control. The dose calibration curve was plotted using red, green and blue channels. While, for the dose mapping measurement, the irradiation exposure of 9.03 minutes was used to deliver a central dose of 25 Gy to the film. The response of the film will be compared with the GC Dose Mapping Report 2022 which used a water equivalent medium as a phantom. For the calibration curve, the red channel of the film was utilized in this study as it had a higher signal than the other channel. The doses obtained at central, minimum and maximum using EBT-XD film with customized blood equivalent phantom were in agreement with that obtained from GC Dose Mapping Report 2022 to be within ±7.6, ±8.51 and ±9.95 respectively. We concluded that the customized blood equivalent phantom together with EBT-XD film has a potential to map the dose in blood irradiator accurately. The doses obtained from EBT-XD film were in the range of doses needed to inhibit the proliferation of the T-lymphocytes with central, minimum and maximum doses were 26.9 Gy, 17.2 Gy and 35.7 Gy respectively.
format Article
author Saiful Fazad, Adiela
Nasir, Muhammad Amir
Noor, Noramaliza Mohd Noor
spellingShingle Saiful Fazad, Adiela
Nasir, Muhammad Amir
Noor, Noramaliza Mohd Noor
Dose map blood irradiator dosimetry system: customized blood equivalent phantom and gafchromic EBT-XD film
author_facet Saiful Fazad, Adiela
Nasir, Muhammad Amir
Noor, Noramaliza Mohd Noor
author_sort Saiful Fazad, Adiela
title Dose map blood irradiator dosimetry system: customized blood equivalent phantom and gafchromic EBT-XD film
title_short Dose map blood irradiator dosimetry system: customized blood equivalent phantom and gafchromic EBT-XD film
title_full Dose map blood irradiator dosimetry system: customized blood equivalent phantom and gafchromic EBT-XD film
title_fullStr Dose map blood irradiator dosimetry system: customized blood equivalent phantom and gafchromic EBT-XD film
title_full_unstemmed Dose map blood irradiator dosimetry system: customized blood equivalent phantom and gafchromic EBT-XD film
title_sort dose map blood irradiator dosimetry system: customized blood equivalent phantom and gafchromic ebt-xd film
publisher Longe Medikal
publishDate 2023
url http://psasir.upm.edu.my/id/eprint/107405/1/107405.pdf
http://psasir.upm.edu.my/id/eprint/107405/
https://ajmedtech.com/index.php/journal/article/view/48
_version_ 1814936553076555776