Examination of the partial discharge behaviour within a spherical cavity in insulation paper of transformer

This paper investigates the behaviour of partial discharge (PD) in transformer insulation paper based on the Finite Element Method (FEM). The three-dimensional (3D) FEM model consists of conductor and insulation paper, representing part of a transformer’s high voltage winding. The conductor’s width,...

Full description

Saved in:
Bibliographic Details
Main Authors: Roslan, Muhammad Hakirin, Azis, Norhafiz, Ab Kadir, Mohd Zainal Abidin, Jasni, Jasronita, Mohd Yousof, Mohd Fairouz
Format: Article
Language:English
Published: Universiti Putra Malaysia 2023
Online Access:http://psasir.upm.edu.my/id/eprint/107808/1/05%20JST-3775-2022.pdf
http://psasir.upm.edu.my/id/eprint/107808/
http://www.pertanika.upm.edu.my/pjst/browse/regular-issue?article=JST-3775-2022
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
Language: English
id my.upm.eprints.107808
record_format eprints
spelling my.upm.eprints.1078082024-11-05T02:03:05Z http://psasir.upm.edu.my/id/eprint/107808/ Examination of the partial discharge behaviour within a spherical cavity in insulation paper of transformer Roslan, Muhammad Hakirin Azis, Norhafiz Ab Kadir, Mohd Zainal Abidin Jasni, Jasronita Mohd Yousof, Mohd Fairouz This paper investigates the behaviour of partial discharge (PD) in transformer insulation paper based on the Finite Element Method (FEM). The three-dimensional (3D) FEM model consists of conductor and insulation paper, representing part of a transformer’s high voltage winding. The conductor’s width, height, and length used in this study were 2.4 mm, 11.5 mm, and 16 mm. An insulation paper thickness of 1 mm was modelled around the conductor. An internal cavity with a diameter of 0.5 mm cavity was introduced within the insulation paper. This study introduced two locations of the spherical cavities at the centre and left corner of the insulation paper: Location 1 (L1) and Location 2 (L2). An AC voltage of 33 kV, 50 Hz, was applied to the conductor while the bottom of the insulation paper was grounded. The model was used to study the electric field distribution within the insulation paper and its effect on PD current and charge magnitude. The influence of cavity location on the charge magnitude was also examined. It is found that the electric field distribution is influenced by the conductor configuration as well as the location of the cavity. The electric field in the cavity is the highest at L1 compared to L2. The first PD occurs faster for the cavity with a high electric field. Due to the PD occurrence at the same inception field, the real PD current and charge magnitude is similar at different locations. The apparent PD current and charge magnitude induced at the ground electrode is slightly higher at L1 than at L2. Universiti Putra Malaysia 2023-04-07 Article PeerReviewed text en cc_by_nc_nd_4 http://psasir.upm.edu.my/id/eprint/107808/1/05%20JST-3775-2022.pdf Roslan, Muhammad Hakirin and Azis, Norhafiz and Ab Kadir, Mohd Zainal Abidin and Jasni, Jasronita and Mohd Yousof, Mohd Fairouz (2023) Examination of the partial discharge behaviour within a spherical cavity in insulation paper of transformer. Pertanika Journal of Science and Technology, 31 (3). pp. 1209-1221. ISSN 0128-7680; eISSN: 2231-8526 http://www.pertanika.upm.edu.my/pjst/browse/regular-issue?article=JST-3775-2022 10.47836/pjst.31.3.05
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description This paper investigates the behaviour of partial discharge (PD) in transformer insulation paper based on the Finite Element Method (FEM). The three-dimensional (3D) FEM model consists of conductor and insulation paper, representing part of a transformer’s high voltage winding. The conductor’s width, height, and length used in this study were 2.4 mm, 11.5 mm, and 16 mm. An insulation paper thickness of 1 mm was modelled around the conductor. An internal cavity with a diameter of 0.5 mm cavity was introduced within the insulation paper. This study introduced two locations of the spherical cavities at the centre and left corner of the insulation paper: Location 1 (L1) and Location 2 (L2). An AC voltage of 33 kV, 50 Hz, was applied to the conductor while the bottom of the insulation paper was grounded. The model was used to study the electric field distribution within the insulation paper and its effect on PD current and charge magnitude. The influence of cavity location on the charge magnitude was also examined. It is found that the electric field distribution is influenced by the conductor configuration as well as the location of the cavity. The electric field in the cavity is the highest at L1 compared to L2. The first PD occurs faster for the cavity with a high electric field. Due to the PD occurrence at the same inception field, the real PD current and charge magnitude is similar at different locations. The apparent PD current and charge magnitude induced at the ground electrode is slightly higher at L1 than at L2.
format Article
author Roslan, Muhammad Hakirin
Azis, Norhafiz
Ab Kadir, Mohd Zainal Abidin
Jasni, Jasronita
Mohd Yousof, Mohd Fairouz
spellingShingle Roslan, Muhammad Hakirin
Azis, Norhafiz
Ab Kadir, Mohd Zainal Abidin
Jasni, Jasronita
Mohd Yousof, Mohd Fairouz
Examination of the partial discharge behaviour within a spherical cavity in insulation paper of transformer
author_facet Roslan, Muhammad Hakirin
Azis, Norhafiz
Ab Kadir, Mohd Zainal Abidin
Jasni, Jasronita
Mohd Yousof, Mohd Fairouz
author_sort Roslan, Muhammad Hakirin
title Examination of the partial discharge behaviour within a spherical cavity in insulation paper of transformer
title_short Examination of the partial discharge behaviour within a spherical cavity in insulation paper of transformer
title_full Examination of the partial discharge behaviour within a spherical cavity in insulation paper of transformer
title_fullStr Examination of the partial discharge behaviour within a spherical cavity in insulation paper of transformer
title_full_unstemmed Examination of the partial discharge behaviour within a spherical cavity in insulation paper of transformer
title_sort examination of the partial discharge behaviour within a spherical cavity in insulation paper of transformer
publisher Universiti Putra Malaysia
publishDate 2023
url http://psasir.upm.edu.my/id/eprint/107808/1/05%20JST-3775-2022.pdf
http://psasir.upm.edu.my/id/eprint/107808/
http://www.pertanika.upm.edu.my/pjst/browse/regular-issue?article=JST-3775-2022
_version_ 1814936561631887360